Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Gel dosimetry"”.

  1. Cone Beam Optical Computed Tomography-Based Gel Dosimetry

    … target accuracy of ± 5% for the dose delivery. Gel dosimetry is an attractive option for realizing a tissue-equivalent, 3D dose verification tool with high resolution readout capabilities. However, much important work remains to be completed prior to its acceptance in the clinic. The careful …

    queens Repository record for Cone Beam Optical Computed Tomography-Based Gel Dosimetry (opens in a new tab)

  2. Iterative image reconstruction for optical CT radiochromic gel dosimetry

    Gel dosimeters are a potential tool for measuring the complex dose distributions in modern radiotherapy, which aims to enhance radiation dose precision to tumors and utilizes hypofractionated treatment regimens. Verifying these dose distributions remains an active research area due to the …

    ubc Repository record for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab) Download PDF for Iterative image reconstruction for optical CT radiochromic gel dosimetry (opens in a new tab)

  3. Investigations in x-ray computed tomography polyacrylamide gel dosimetry

    Polyacrylamide gels (PAGs) are radiosensitive materials currently under development for use as three dimensional (3D) dosimeters in radiation therapy. Dose information is recorded in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method …

    ubc Repository record for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab) Download PDF for Investigations in x-ray computed tomography polyacrylamide gel dosimetry (opens in a new tab)

  4. Applications of x-ray computed tomography polymer gel dosimetry

    … advances. X-ray computed tomography (CT) polymer gel dosimetry is a unique type of dosimeter that has many advantages and the potential to address some of the challenges in the verification of dose delivery and calculation in radiation therapy. This dissertation investigates the advancement of an …

    uvic Repository record for Applications of x-ray computed tomography polymer gel dosimetry (opens in a new tab)

  5. Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy

    … at best in quasi-3D. The implementation of 3D dosimetry into clinical dosimetry requires attention to safety, accuracy, and rigorous validation prior to any routine patient treatment. Polymer gel detectors have previously been shown to be a useful tool to capture complex 3D dose distributions …

    houston Repository record for Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy (opens in a new tab)

  6. X-ray computed tomography for performing polymer gel dosimetry : a feasibility study

    … three dimensional (3D) dosimeter. Polymer gels are novel, inherently 3D, tissue equivalent radiation dosimeters. Traditionally, dose distributions recorded in polymer gel are read out using magnetic resonance imaging (MRI). Presented here is a feasibility study on a new 3D dosimetry …

    ubc Repository record for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab) Download PDF for X-ray computed tomography for performing polymer gel dosimetry : a feasibility study (opens in a new tab)

  7. Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry

    Polymer gel dosimetry, in conjunction with x-ray computed tomography (x-ray CT) imaging, is a three-dimensional dosimetric tool that shows promise in the verification of complex radiation therapy treatments. Previous studies have shown that x-ray CT imaging of gel dosimeters is robust, easy-to-use, …

    uvic Repository record for Assessment of X-ray computed tomography dose in normoxic polyacrylamide gel dosimetry (opens in a new tab)

  8. Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry

    … of MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) polymer gel dosimeters have been characterized. The variations of speed of sound, ultrasonic attenuation coefficient and density of MAGIC gel with radiation dose and temperature have been quantified. This extends work …

    soton Download PDF for Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry (opens in a new tab)

  9. 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

    Polymer gel dosimetry has been used since the 1990s, and several studies have shown that this detector system can be used for verification of static absorbed dose distributions in three dimensions (3D). Its unique properties, such as high resolution, normal tissue equivalence and independency of …

    lund Repository record for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab) Download PDF for 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry (opens in a new tab)

  10. An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions

    … measured dose distributions in true 3D. True 3D dosimetry systems have been a subject of research for more than 3 decades. Gel dosimetry with optical computed tomography (CT) scanning using visible light wavelengths has been under investigation and development for much of this time. A lack of …

    adelaide Repository record for An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions (opens in a new tab)

  11. Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry

    … It is hypothesized that deformable polymer gels can provide volumetric dosimetric information for the assessment of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos. This hypothesis will be investigated by (1) using stationary polymer gel dosimeters (PGDs) to benchmark …

    ubc Repository record for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab) Download PDF for Evaluation of spatial and dosimetric accuracy of adaptive radiotherapy on Ethos using polymer gel dosimetry (opens in a new tab)

  12. An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification

    X-ray computed tomography (CT) polymer gel dosimetry (PGD) is an attractive tool for three-dimensional (3D) radiation therapy (RT) treatment verification due to the availability of CT scanners in RT clinics. Nevertheless, wide-spread use of the technique has been hindered by low signal-to-noise CT …

    uvic Repository record for An x-ray computed tomography polymer gel dosimetry system for complex radiation therapy treatment verification (opens in a new tab)

  13. Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification

    … challenge that utilizes a 3D NIPAM polymer gel dosimetry system with CBCT readout to verify the dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) and spatially fractionated radiotherapy (SFRT) technique. Three main objectives of this work are 1) to evaluate the …

    ubc Repository record for Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification (opens in a new tab) Download PDF for Clinical applications of 3D polymer gel dosimetry with cone-beam computed tomography readout in dosimetric and spatial accuracy verification (opens in a new tab)

  14. Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout

    … dosimeters for brachytherapy. Radiochromic gel dosimeters with optical computed tomography (CT) readout would provide such a dosimeter, but the insertion of brachytherapy catheters into the gel cause streak artifacts in the reconstructed dose distributions, ruining the dosimeter’s accuracy. …

    queens Repository record for Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout (opens in a new tab)

  15. Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography

    Polymer gel dosimeters are a three dimensional (3D) dosimetry system that may be conveniently applied for verifying highly conformal radiation therapies where standard dosimetry techniques are insufficient. Polymer gel dosimetry with optical computed tomography (OptCT) can be used to measure …

    queens Repository record for Validation of conformal radiotherapy treatments in 3D using polymer gel dosimeters and optical computed tomography (opens in a new tab)

  16. End-to-End Quality Assurance of Complex Radiation Therapy Treatments

    … this work examines: (i) improving film dosimetry readout methods by testing the capabilities of our inhouse diffuse light field and camera film imaging system, as well as developing a new point source film scanner to eliminate stray light issues present in the diffuse light system, (ii) …

    queens Repository record for End-to-End Quality Assurance of Complex Radiation Therapy Treatments (opens in a new tab)

  17. Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος

    … results by the utilization of MRI polymer gel dosimetry methodologies and (b) to optimize the dosimetric radiotherapy results in conformal radiotherapy by the utilization of Magnetic Resonance Imaging in special phantoms.Nowadays, polymer gel dosimeters have been proven a valuable tool for …

    greece Repository record for Ανάπτυξη καινοτόμων τεχνικών ακτινοθεραπείας σε συνδυασμό με ειδικές τεχνικές απεικόνισης μαγνητικού συντονισμού (μαγνητική τομογραφία) με στόχο τη βελτιστοποίηση της ποιότητας των αποτελεσμάτων για τη θεραπεία και την παρακολούθηση της εξέλιξης νεοπλασιών του κεντρικού νευρικού συστήματος (opens in a new tab)

  18. Evaluation of yttrium-90 positron emission tomography dosimetry

    … tumors. Radioembolization dose planning and dosimetry are based on crude, inaccurate assumptions due to the lack of knowledge of patient specific 90Y microsphere distribution. In recent years, the very small 3.1867e-5 internal pair production decay branch of 90Y has been shown to allow for …

    purdue-thes Repository record for Evaluation of yttrium-90 positron emission tomography dosimetry (opens in a new tab)

Page 1 of 2