Results 1 to 20 of 58 for “"Generator control."”
-
Digital Generator Control Unit for Synchronous Brushless Generator
… implementation and improvement of a digital Generator Control Unit (GCU) for a high-speed synchronous brushless generator. The control of variable frequency power system, a preferred candidate in More Electric Aircraft (MEA), becomes a big challenge. Compared with conventional analog GCU, …
-
Design of a Multiloop Pyroelectric Neutron Generator Control System
Pyroelectric neutron generators are compact, low power systems which may be capable of producing short intense pulses of neutrons from D-D fusion reactions. Initial analysis of pyrofusion dynamics has indicated the potential to manipulate the pulse characteristics through system control. This …
-
Wind Turbine Generator Condition Monitoring via the Generator Control Loop
… wind turbine driven doubly fed induction generators. The work describes the significant development of a physical condition monitoring Test Rig and its MATLAB Simulink model to represent modern variable speed wind turbine and the innovation and application of the rotor side control signals …
-
Wake generator control of flow distortion induced tonal noise in fans
… blades with flow disturbances. A novel way to control this noise is to generate further disturbances which interact with the fan to produce anti-noise. Flow disturbances can be created using an array of cylindrical rods protruding into the duct. The variation of the lengths and orientation of …
-
Wind turbine power generation emulation via doubly fed induction generator control
In this thesis, we emulate a Wind Turbine Generator by driving a Doubly Fed Induction Generator (DFIG) via a DC motor with variable input torque capability. The two circuits of concern are the DFIG and Supply-side circuits. They are electrically coupled with back-to-back Space Vector Modulators …
-
Doubly Fed Induction Generator Control Using Artificial Neural Network for Wind Generation System
… wind turbines, the wind generation system needs generators. The doubly fed induction generator is the most commonly used due to its high energy transfer efficiency, reliability, and low maintenance cost. The control of DFIG parameters is crucial to the dynamic performance of the wind generation …
-
A virtual synchronous generator control in the power system with high penetration of renewable energies--weak grid!
… a paradigm shift from conventional synchronous generators (SG) based systems to mixed generation systems with a large portion of renewable energies (RE). This has resulted in the erosion of the conventional power system’s frequency control. This is because, inertia of the system declines with …
-
Novel sensorless generator control and grid fault ride-through strategies for variable-speed wind turbines and implementation on a new real-time simulation platform
… turbines exist. One is the doubly-fed induction generator (DFIG) with a partial-scale power electronic converter. The other is the permanent-magnet synchronous generator (PMSG) with a full-scale power electronic converter. This research is to develop the model of these two wind turbine systems …
-
Microprocessor-based on-load valve sequencing for a turbo-alternator
… the way to the full-scale computerising of turbo-generator control systems, this type of testing system may be used under the control of a full-size supervisory computer. This microprocessor-based testing system provides test sequencing of the valves of an Electro-Hydraulic Governor. The hardware …
-
Development of a power electronics for a flywheel energy storage system
… nature of permanent magnet brushless DC motor/generator, the operation of three-phase voltage source inverter/rectifier can be simplified to that of a bi-directional DC-DC converter, allowing the use of mostly analog control. Second, there is a problem associated with the existing six-step …
-
Ultraschallbasiertes in situ Geometrie-Messsystem für dünnwandige Stahlringe
… it can be used to determine the set-values for a control system, which establishes a constant wall thickness by fast movements of a turning tool servo for clamping-distorted rings. The measuring system consists of a signal generator, control electronics, a 15 MHz transducer and a PC system for …
-
Commissioning a 400 Hz rotary inverter
… by the use of a blower fan and shroud. The generator control unit monitors and regulates all parameters on the unit except for case temperature and blower fan pressure. A telemetering system was designed and built to monitor and display these parameters.
-
Power System Frequency Control and Stability Analysis With Increasing Renewable Energy Penetration Level
… and the replacement of traditional synchronous generators, the issues associated with the deteriorated performance of power system frequency regulation and potential grid frequency instability become more significant. In this dissertation, the inertial control algorithms are investigated and …
-
Constant voltage, constant frequency operation of a self-excited induction generator
In this thesis, control schemes for the self-excited induction generator are developed with Matlab/Simulink. Self-excited induction generator is considered as a constant voltage-constant frequency supply for an isolated load. A wind turbine is assumed to be the variable-speed drive of the induction …