Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"Generator-Collector"”
-
Generator-Collector Sensors for Water Quality Monitoring
… studies into the development of submicron-gap generator-collector electrodes are provided alongside a variety of electrochemical methods.The aim of this project is to fabricate novel, low-cost, electrochemical devices with the potential for development into sensors for water quality monitoring. …
-
Numerical Simulation of Complex Microelectrode Geometrics
… formulation.</p><p>Steady state diffusion at a generator-collector double microband for a diffusion limited reaction is used to validate a two-dimensional BEM model, and investigate mesh discretisation effects. Optimisation of the mesh and implementation of higher order boundary elements are …
-
Advances in electrochemical simulation and its application to electroanalysis
… Chapter 6 looks at dual band electrodes used in generator-collector mode, and how this can be used to simultaneously measure the concentration of two species in solution. Chapter 7 looks at interdigitated arrays of band and ring electrodes in generator-collector mode, and develops a model to …
-
Explosive Vapor Generation and Sampling in Conjunction with Ion Mobility Spectrometry
… objective is to demonstrate the use of the vapor generator in various applications keeping in mind potential field scenarios involving explosives. A vapor generator/collector system was developed which gives reproducible pulses of TNT vapors at nanogram levels. The use of this technology was …
-
Electrochemical titrations with dual microband electrodes
The main objective of this thesis is to present a generator-collector mode titration with dual parallel microband electrodes and a miniaturisation of an electroanalytical method. The system is based on manipulation of the mass transport, which is accomplished by using screen-printed microband …
-
Electrochemical sensor interface
… cyclic voltammetry, square wave voltammetry and generator collector voltammetry. The data acquisition system interfaces to a smartphone, operates from a rechargeable battery and is of suitable form factor to ensure that it’s fully portable. By utilising commercially available components, this …
-
Sensor Innovations Based on Modified Carbon Electrodes
… sensing mechanism based on a nano-gap generator – collector electrode system is proposed.Chapters 6 and 7 are dedicated to gas sensing with a novel electrochemical system based on ionomer spheres in contact to the working electrode. In Chapter 6 Dowex ionomer particles are impregnated …
-
The electrochemistry of hydrogen sulfide in room temperature ionic liquids
… at ring-recessed disc microelectrode arrays in generator-collector mode using potential step chronoamperometry.</li><ul></ul></ul></p><p>The results presented show that room temperature ionic liquids perform well as solvents in gas sensors, and could be viable alternatives to traditional organic …
-
Hydrous iridium oxide for in-situ pH sensing: electrodeposition, properties and applications.
… method, the RRDE is not used in the classical generator collector mode with amperometric detection on the ring, but with the ring as a potentiometric pH sensor. Hydrous iridium oxide films (HIROF) were electrodeposited to serve as thin film pH sensors. The chemistry of the deposition medium …
-
Formation and characterisation of electroanalytical junctions
Electrochemical and microscopy techniques are used to form and investigate novel nanojunctions. Initial investigative work is carried out using junction arrays formed via layer-by-layer deposition techniques. In depth studies into novel paired gold junction electrodes formed using simple …
-
Novel Sensors for the Detection of Biologically Important Species
… voltammetric methods, (i) based on a dual-plate generator-collector micro-trench electrode (steady state) and (ii) based on square-wave voltammetry (transient), are applied and compared in terms of mechanistic resolution. A combination of experimental data is employed to obtain new insights into …
-
Electrochemical sensors for integration on silicon
Water quality monitoring is crucial to ensure the safe consumption of drinking water by humans. It is of such importance that the UN has included a specific goal for the improvement of water and sanitation in their Sustainable Development Goals (SDG). According to the UN, a staggering 3 in 10 …
-
Nanowire and microband arrays for enhanced electrochemical sensing
Water quality monitoring is crucial to ensure that (i) water is safe to be consumed by humans, and (ii) that it is of adequate quality for aquatic life. The European Union has dedicated two of its seventeen sustainable development goals for 2030 to water quality. While many methods are available to …
-
Micro- and nanogap based biosensors
Biosensors are used for the detection of a range of analytes for applications in healthcare, food production, environmental monitoring and biodefence. However, many biosensing platforms are large, expensive, require skilled operators or necessitate the analyte to be labelled. Direct electrochemical …
-
Modifikace utěsnění víka primárního kolektoru PG VVER 1000
Tato diplomová práce se zabývá záměnou těsnění víka primárního kolektoru parního generátoru reaktoru VVER 1000. Původní těsnění pomocí niklových kroužků je nahrazeno hřebenovým těsněním s expandovaným grafitem. V práci jsou srovnány vlastnosti obou typů těsnění a proveden výpočet nové i původní …