Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Germanium Detectors"”.

  1. Neutron induced peaks in germanium detectors

    Peaks from fast and thermal neutron interactions in a HPGe detector have been studied using neutrons from 2C3f2, the rS21,ui8n() and the B2i(0ir,9n) reactions. In the latter case, it was possible to separate the neutron induced events using the TOF method. The peaks from (n,n’) interactions in the …

    ubc Repository record for Neutron induced peaks in germanium detectors (opens in a new tab) Download PDF for Neutron induced peaks in germanium detectors (opens in a new tab)

  2. Alpha-event characterization for germanium detectors

    … interactions on the passivated surface of a germanium detector is presented. Germanium detectors can be used to search for both neutrinoless double beta decay of 76Ge and direct interaction of dark matter. In order to increase the sensitivity to both neutrinoless double beta decay and dark …

    lmu-germany Repository record for Alpha-event characterization for germanium detectors (opens in a new tab)

  3. Calibration of Infrared Photons in Cryogenic Germanium Detectors

    … for WIMPs. It is based primarily on deploying germanium and silicon detectors at cryogenic temperatures to search for direct WIMP-nucleus elastic scattering interaction through which lattice vibrations are generated and sensed in one of the coldest detectors ever built. The new phase of …

    queens Repository record for Calibration of Infrared Photons in Cryogenic Germanium Detectors (opens in a new tab)

  4. Sensitivity comparison of intrinsic germanium detectors with various efficiencies

    … data for a wide range of relative efficiency germanium detectors. The purpose was to determine the sensitivity of various efficiency high-purity (P-type) germanium detectors produced by a single manufacturer. Selecting efficiency as the only variable and essentially all other variables …

    ut-knoxville Repository record for Sensitivity comparison of intrinsic germanium detectors with various efficiencies (opens in a new tab)

  5. The preparation and operation of lithium drift germanium detectors

    Lithium drifted germanium detectors have been prepared for use as high resolution gamma ray spectrometers. The fabrication procedure and the problems which can arise during preparation are discussed in detail. Using the techniques described, germanium detectors having the following characteristics …

    ubc Repository record for The preparation and operation of lithium drift germanium detectors (opens in a new tab) Download PDF for The preparation and operation of lithium drift germanium detectors (opens in a new tab)

  6. CHARACTERIZATION OF PARTIAL CHARGE COLLECTION INDUCED BY NEUTRON DAMAGE IN HIGH-PURITY GERMANIUM DETECTORS

    … and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed …

    unm Repository record for CHARACTERIZATION OF PARTIAL CHARGE COLLECTION INDUCED BY NEUTRON DAMAGE IN HIGH-PURITY GERMANIUM DETECTORS (opens in a new tab)

  7. Neural Network Methods for Improving Signal Processing in High-Purity Germanium Detectors for Rare Event Searches

    … for self-supervised denoising of high-purity germanium p-type point contact detector signals. Faithful extraction of information from noisy signals is critical to the sensitivity of neutrinoless double-beta decay experiments, and deep learning-based denoising offers a complementary approach to …

    queens Repository record for Neural Network Methods for Improving Signal Processing in High-Purity Germanium Detectors for Rare Event Searches (opens in a new tab)

  8. The CAGE Scanner: Development of a Novel Surface Event Rejection Technique in High Purity Germanium Detectors

    … rare event search with the use of semiconductor detectors constructed of high-purity germanium, enriched in the candidate isotope 76Ge. Precise understanding of detector response to radiation is crucial to the success of this experimental effort. This work describes the operation and improvement …

    washington Repository record for The CAGE Scanner: Development of a Novel Surface Event Rejection Technique in High Purity Germanium Detectors (opens in a new tab)

  9. The Krypton String Test Cryostat: Characterizing Surface Charge-Induced Dead Layers on High Purity Germanium Detectors

    … questions in physics. LEGEND is using germanium detectors, enriched in the double beta-decaying isotope $^{76}$Ge to search for this rare process. Background reduction is crucially important to rare event searches like LEGEND and understanding these germanium detectors is a necessary …

    washington Repository record for The Krypton String Test Cryostat: Characterizing Surface Charge-Induced Dead Layers on High Purity Germanium Detectors (opens in a new tab)

  10. Studies of machine learning for event reconstruction in the SNO+ detector and electronic noise removal in p-type point contact high purity germanium detectors

    … from a p-type point contact high purity germanium detector located at Queen's University in Kingston, Ontario, Canada and similar to the germanium detectors used in the arrays of large-scale experiments. It is shown through multiple analyses that denoising using these methods preserves …

    queens Repository record for Studies of machine learning for event reconstruction in the SNO+ detector and electronic noise removal in p-type point contact high purity germanium detectors (opens in a new tab)

  11. The GALATEA test facility and a first study of alpha-induced surface events in a Germanium detector

    Germanium detectors are a choice technology in fundamental research. They are suitable for the search for rare events due to their high sensitivity and excellent energy resolution. As an example, the GERDA (GERmanium Detector Array) experiment searching for neutrinoless double beta decay is …

    lmu-germany Repository record for The GALATEA test facility and a first study of alpha-induced surface events in a Germanium detector (opens in a new tab)

  12. DESIGN, DEVELOPMENT AND VALIDATION OF NOVEL ELECTRICAL CONTACTING SYSTEMS, MECHANICAL ENCAPSULATION SOLUTIONS AND HIGH-RESOLUTION INTEGRATED CHARGE-SENSITIVE PREAMPLIFIERS FOR ADVANCED HIGH-PURITY GERMANIUM DETECTORS

    Segmented High-Purity Germanium detectors are widely used in modern gamma spectroscopy experiments due to their outstanding energy resolution and precise position sensitivity. However, detailed technical and manufacturing specifications for these detectors are typically proprietary, as they are …

    milano Repository record for DESIGN, DEVELOPMENT AND VALIDATION OF NOVEL ELECTRICAL CONTACTING SYSTEMS, MECHANICAL ENCAPSULATION SOLUTIONS AND HIGH-RESOLUTION INTEGRATED CHARGE-SENSITIVE PREAMPLIFIERS FOR ADVANCED HIGH-PURITY GERMANIUM DETECTORS (opens in a new tab)

  13. Neutron detection with the Miniball germanium array

    … targets were studied with the segmented germanium detector array Miniball, detecting electromagnetic radiation, and the silicon-based T-Rex detector for charged particles. This thesis investigates signals in Miniball following inelastic scattering of neutrons on 72Ge, populating its first …

    chalmers Repository record for Neutron detection with the Miniball germanium array (opens in a new tab)

  14. KMESS: an open source software package using a semi-empirical mesh-grid method for the modeling of germanium detector efficiencies

    … the absolute full-energy peak efficiencies of germanium detectors are primarily either too time consuming or not economically viable. In addition, these approaches are difficult to use for arbitrary source shapes and counting geometries. An open source software package, KMESS (Kevin's Mesh …

    texas Repository record for KMESS: an open source software package using a semi-empirical mesh-grid method for the modeling of germanium detector efficiencies (opens in a new tab)

  15. Mitigation Strategies of 42K Background and Development of Radiopure Materials for the LEGEND-1000 0νββ Decay Experiment

    … 0νββ decay with 1000 kg of high-purity enriched germanium 76Ge detectors submerged in liquid argon located deep underground. 42K is one of the radioactive isotopes produced in natural liquid argon; its β-decay overlaps the 0νββ decay signal region and causes a significant background. Monte Carlo …

    utk-theses Repository record for Mitigation Strategies of 42K Background and Development of Radiopure Materials for the LEGEND-1000 0νββ Decay Experiment (opens in a new tab)

  16. Double-Beta Decay of 96Zr and Double-Electron Capture of 156Dy to Excited Final States

    … was also investigated. Two coaxial high-purity germanium detectors were used in coincidence to detect gamma rays produced by the daughter nucleus as it de-excited to the ground state. After collecting 1.92 years of data with 17.91 g of enriched 96Zr, half-life limits at the level of 10^20 yr …

    duke Repository record for Double-Beta Decay of 96Zr and Double-Electron Capture of 156Dy to Excited Final States (opens in a new tab)

  17. Search for metastability of 2S muonic neon

    … of the PSI cyclotron trap. A pair of intrinsic germanium detectors were used in coincidence to search for the two photon decay of the 2S-state. Both energy and time information from two photon events were written to disk for off-line analysis. Data were accumulated for neon pressures of 40 and …

    wm-mary Repository record for Search for metastability of 2S muonic neon (opens in a new tab)

Page 1 of 4