Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 61 for “"Germanium detector"”.

  1. Monte Carlo simulations of Germanium detector efficiency curves

    The use of Germanium detectors to study gamma-rays has become common practice in most modern science laboratories. These detectors often need to be calibrated and characterized for different gamma-ray source geometries, energies, and source-to-detector distances. The use of Monte Carlo based …

    texas Repository record for Monte Carlo simulations of Germanium detector efficiency curves (opens in a new tab) Restricted access

  2. A Measurement of The Response of A High Purity Germanium Detector to Low-Energy Nuclear Recoils

    … result is a new way to build a compact neutrino detector which unlocks new channels to test the Standard Model. A semiconductor germanium detector, a technology that has been developed by many dark matter direct detection experiments due to its excellent energy resolution and low-energy …

    duke Repository record for A Measurement of The Response of A High Purity Germanium Detector to Low-Energy Nuclear Recoils (opens in a new tab)

  3. The GALATEA test facility and a first study of alpha-induced surface events in a Germanium detector

    Germanium detectors are a choice technology in fundamental research. They are suitable for the search for rare events due to their high sensitivity and excellent energy resolution. As an example, the GERDA (GERmanium Detector Array) experiment searching for neutrinoless double beta decay is …

    lmu-germany Repository record for The GALATEA test facility and a first study of alpha-induced surface events in a Germanium detector (opens in a new tab)

  4. A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

    … Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously …

    umn Repository record for A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test (opens in a new tab)

  5. KMESS: an open source software package using a semi-empirical mesh-grid method for the modeling of germanium detector efficiencies

    … the absolute full-energy peak efficiencies of germanium detectors are primarily either too time consuming or not economically viable. In addition, these approaches are difficult to use for arbitrary source shapes and counting geometries. An open source software package, KMESS (Kevin's Mesh …

    texas Repository record for KMESS: an open source software package using a semi-empirical mesh-grid method for the modeling of germanium detector efficiencies (opens in a new tab)

  6. Design Criteria for High Resolution Gamma-Ray Body Counting Systems

    … and partial-body counters have used NaI(Tl) detectors for gamma-ray analysis which have provided good sensitivity but have possessed poor gamma-ray resolution. With the increasing availability of more efficient germanium semi-conductor detectors, which offer high resolution gamma-ray …

    glasgow Download PDF for Design Criteria for High Resolution Gamma-Ray Body Counting Systems (opens in a new tab)

  7. Benchmarking of neutron flux parameters at the USGS TRIGA reactor in Lakewood, Colorado

    … diluted gold wires. A well calibrated and stable germanium detector setup as well as fourteen samplers were designed and built to achieve accuracy in the measurement of the neutron flux. Furthermore, the flux monitoring bores of the GSTR core were used for the first time to measure neutron flux …

    colo-mines Repository record for Benchmarking of neutron flux parameters at the USGS TRIGA reactor in Lakewood, Colorado (opens in a new tab)

  8. Line shapes in Ge (Li) detectors

    … of the peaks in gamma ray spectra produced by a germanium detector. From these arguments a function was derived to represent these peak shapes. This function has been used to fit several gamma ray peaks at various energies and the resulting values obtained for the functions parameters were …

    carleton Repository record for Line shapes in Ge (Li) detectors (opens in a new tab)

  9. Profiling calibration devices and simulating cosmic-ray muon spallation for Hyper-Kamiokande

    … simulation (WCSim) framework to simulate the detector’s response to these interactions. The result of the simulations is a machine learning classification which classifies between DSNB events and spallation-induced low-energy events. The results of this classification are a promising …

    whiterose Download PDF for Profiling calibration devices and simulating cosmic-ray muon spallation for Hyper-Kamiokande (opens in a new tab)

  10. Studies of machine learning for event reconstruction in the SNO+ detector and electronic noise removal in p-type point contact high purity germanium detectors

    … from a p-type point contact high purity germanium detector located at Queen's University in Kingston, Ontario, Canada and similar to the germanium detectors used in the arrays of large-scale experiments. It is shown through multiple analyses that denoising using these methods preserves …

    queens Repository record for Studies of machine learning for event reconstruction in the SNO+ detector and electronic noise removal in p-type point contact high purity germanium detectors (opens in a new tab)

  11. Use of a High-Purity Germanium Semiconductor Detector for Rapid Post-Nuclear Event Forensics

    … thesis investigates the ability of a high-purity germanium detector to perform post-detonation forensics on the debris from several types of nuclear weapons 24 hours after detonation. The ultimate result of this analysis would be the deployment of this detector on an autonomous robot for sample …

    tamu Repository record for Use of a High-Purity Germanium Semiconductor Detector for Rapid Post-Nuclear Event Forensics (opens in a new tab)

  12. The CAGE Scanner: Development of a Novel Surface Event Rejection Technique in High Purity Germanium Detectors

    … rare event search with the use of semiconductor detectors constructed of high-purity germanium, enriched in the candidate isotope 76Ge. Precise understanding of detector response to radiation is crucial to the success of this experimental effort. This work describes the operation and improvement …

    washington Repository record for The CAGE Scanner: Development of a Novel Surface Event Rejection Technique in High Purity Germanium Detectors (opens in a new tab)

  13. Integrated modeling to design a digital twin of the Massachusetts Institute of Technology molten salt irradiation flow loop

    … simulation was developed to predict gamma ray detector responses under various operational modes and experimental conditions. The simulation calculates activation cross sections, neutron activation, decay of FLiBe molten salt, and simulates the detector response of a Reverse Electrode Germanium …

    texas Repository record for Integrated modeling to design a digital twin of the Massachusetts Institute of Technology molten salt irradiation flow loop (opens in a new tab)

  14. A method for measuring radioxenon emanation with cryotrapping and γ spectroscopy

    … are measured by γ spectroscopy with a Hyper-Pure Germanium detector. Preliminary tests demonstrated the capability of this new process to make reproducible emanation measurements with quantifiable uncertainty. The results measured U₃O₈ radioxenon emanation coefficients of 0.016 ± 0.002 for ¹³³Xe …

    texas Repository record for A method for measuring radioxenon emanation with cryotrapping and γ spectroscopy (opens in a new tab)

  15. The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics

    … gamma ray spectrometer incorporating a germanium lithium-drift radiation detector is described. Sources of electrical noise in detectors and low-noise field-effect transistor preamplifiers are discussed. Modifications were made to available preamplifier circuits with a slight improvement …

    ubc Repository record for The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics (opens in a new tab) Download PDF for The development of a germanium lithium-drift gamma spectrometer and preliminary applications to positron physics (opens in a new tab)

  16. Neutron detection with the Miniball germanium array

    … targets were studied with the segmented germanium detector array Miniball, detecting electromagnetic radiation, and the silicon-based T-Rex detector for charged particles. This thesis investigates signals in Miniball following inelastic scattering of neutrons on 72Ge, populating its first …

    chalmers Repository record for Neutron detection with the Miniball germanium array (opens in a new tab)

  17. INVESTIGATION AND EXTENSION OF SELF-CALIBRATION RADIOMETRY.

    … calibration showed disagreement less than 0.1%. Germanium and GaAsP detectors were also investigated in the infrared and deep blue wavelengths. The germanium detector showed significant recombination loss of photogenerated carriers due to the ion implantation fabrication process. GaAsP detectors …

    arizona-thes Repository record for INVESTIGATION AND EXTENSION OF SELF-CALIBRATION RADIOMETRY. (opens in a new tab)

  18. Short lived radionuclide modeling from nuclear weapons test sites and nuclear power plant accidents

    … by a worldwide network of air sensors, seismic detectors and several other techniques. At the site of the incident, contaminants are distributed and can provide insight into the time of the incident and type of incident. That information can then be used to affect policy decisions or better …

    texas Repository record for Short lived radionuclide modeling from nuclear weapons test sites and nuclear power plant accidents (opens in a new tab)

  19. Evaluation Of Gamma-Ray Emissions from Fly Ash

    … for gamma radiation emission using a high purtiy germanium detector. The U-238 and th-232 decay daughters were specifically targeted. From these decay chains, Pb-214 and Bi-214 gamma-ray emissions were measured in both the fly ash and raw coal samples.

    mo-state Repository record for Evaluation Of Gamma-Ray Emissions from Fly Ash (opens in a new tab)

  20. Thickness measurement using ion beam techniques

    … towards light elements. The High purity Germanium detector also found it difficult to resolve peaks of elements (Magnesium and. Aluminum) that were close to one another. The GeoPIXE software showed inconsistent results for all the measurements. However the results showed good agreement …

    nwu-za Repository record for Thickness measurement using ion beam techniques (opens in a new tab)

Page 1 of 4