Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 89 for “"Glass capillary"”
-
High resolution gas chromatography of conjugated estrogens with glass capillary columns
… and β-estradiol/α-dihydroequilin, capillary column gas chromatography was investigated. A variety of derivatives of estrogens, suitable for gas chromatography, such as trimethylsilyl ethers, methoxime-trimethyl-silyl ethers, tert.butyl dimethyl silyl ethers, heptafluorobutyrates, …
-
Investigation to the reciprocative thermal cycling of multiphase reactor train
… of the reciprocating reactor train in the micro glass capillary was also investigated. Studies showed that the parabolic shaped reactor flow profile was dispersed when subjected to a higher velocity in a pressure-driven flow. The relationship between the inner diameter of the three glass …
-
Investigation of Novel Microseparation Techniques
… separation channel. Both fiber-based and porous glass capillary-based planar EFGF devices with changing cross-sectional area (CCSA) channels were constructed and evaluated with the aid of a home-made scanning laser-induced fluorescence detection system. The fiber-based CCSA EFGF devices gave …
-
Generation Of Sub-Wavelength Acoustic Stationary Waves In Microfluidic Platforms: Theory And Applications To The Control Of Micro-Nanoparticles And Biological Entities.
… in an acoustically actuated microfluidic glass capillary. Here, the PZT (Lead Zirconate Titanate)glass capillary actuator mechanism performs bioanalytical methods such as collection, separation and mixing at microscale, at low voltage drives, enabling production of battery operated …
-
Experimental studies of nucleate pool boiling from artificial active sites
… cylindrical cavity was investigated visually. A glass capillary was inserted through the heat transfer surface and the bore supported ebullition in the absence of naturally occurring nuclei. When ebullition occurred at the surface, a falling liquid film was observed on the cavity wall. Three …
-
Development of Capillary Vibrating Sharp-Edge Spray Ionization for Improving Continuous Flow Mass Spectrometry Analysis
Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) is new ionization technique developed in the year of 2018. This ionization technique has attractive features such as simplicity, compactness, ease of manipulation, low costs, compatible with continuous flow, etc. However, the development of …
-
Preparation of clay-coated glass surfaces for microfluidics-based study on clay-fluid interactions
… developed by functionalizing traditional glass or PDMS surface with geomaterials (e.g., calcite, quartz, clay) can represent the physico-chemical properties of the natural porous media and have been used during the last few years to understand and evaluate the solid-fluid physicochemical …
-
Small chamber testing of insecticidal fumigants.
… Quart Mason jars; weighed fumigant-filled glass capillary tubes; absorbent paper; and screen cages attached under jar lids and charged with insects through readily sealed openings constituted the apparatus selected. At room temperature a two-hour evaporation period, five-hour exposure …
-
Adsorption of ions at a water surface.
… the passage of an electric current through a capillary tube containing water caused a movement of the water surface, which was exactly proportional to the quantity of electricity passed. He also noted that the passage of a current through a liquid containing gas bubbles caused the latter to …
-
New Insights Into Generating Microfluidic Monodisperse Drops
… our experimental findings for a variety of glass capillary microfluidic devices is also presented. Moreover, a phase diagram of drop diameter as a function of inner and outer fluid flow rates indicates optimal flow parameters for the production of monodisperse drops. Our findings emphasize …
-
Liquid Flowmeter Using Thermal Measurement; Design and Application
… The thermal mass flowmeter consists of a glass capillary, a tungsten wire heater, and aresistance temperature detector (RTD) sensor. The heater and sensors are integrated on the surface ofthe glass capillary. Noncontact flow measurement between sensor and liquid sample prevents …
-
Microfabrication of a high sensitivity fluidic AFM probe
… polymer; and 4) a microfluidic side entry glass capillary interconnect to a bulk microfluidic channel. The technology incorporates the ability to manipulate the internal fluid pressure at the cantilever terminus to enable controlled aspiration of single cells. This work could enable the …
-
Magnetic Bubble Micromotors: Robust, Fast, and Dynamically Self-Assembling at Liquid–Gas Interfaces
… micromotors: a new form of driven matter. Using glass capillary microfluidics, stable bubbles can be generated with a hard outer shell formed of silica and iron oxide nanoparticles that prevents gas inside from escaping. These buoyant micromotors have an average diameter of 280 microns and …
-
MICRO- AND NANO-MATERIALS FOR DRUG DELIVERY AND BIOIMAGING APPLICATIONS
… silica microparticles are generated by glass-capillary microfluidic devices via double emulsion templates. These silica microcapsules can be used for drug delivery.
-
Immobilized liposomes as a model of cells in a laminar flow field
… for attaching fluorescein labeled liposomes to glass capillaries are presented. The immobilization of liposomes to glass surfaces can be applied as a useful tool for the observation of structural changes taking place on their surface when they are subjected to a uniform flow. This would permit …
-
Surface phenomena in capillary flow of polymer solutions.
… polymer adsorption are reported for laminar capillary flow of dilute aqueous solutions of three homologous compounds of Polyox, denoted by WSR 301, Coagulant and FRA. Measurements were carried out using very dilute solutions in the polymer concentration range 5 to 200 ppm and very fine glass …
Page 1 of 5