Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 35 for “"Glaucoma--Treatment"”

  1. Hyaluronan hydrogel modified intraocular implants for glaucoma treatment

    Glaucoma is a very prevalent eye disease with more than 60 million people affected worldwide. The only form of therapy is the artificial lowering of the intraocular pressure of the aqueous humor, which is the main cause for the disease. This can be achieved for example by the application of an …

    heid-diss Repository record for Hyaluronan hydrogel modified intraocular implants for glaucoma treatment (opens in a new tab)

  2. Development of Minimally Invasive Devices and Technologies for Open-Angle Glaucoma Treatment

    Primary open-angle glaucoma is a progressive disease affecting nearly 60 million people and is the leading cause of blindness worldwide. People with glaucoma may not notice symptoms or feel damage as it occurs because one of the only major risks and causative factors of the disease is elevated …

    jhu Repository record for Development of Minimally Invasive Devices and Technologies for Open-Angle Glaucoma Treatment (opens in a new tab)

  3. Adapted Motivational Interviewing to improve uptake of glaucoma treatment in Bauchi, Nigeria

    Background: Glaucoma is a major cause of irreversible blindness in Africa due to its high prevalence, early age of onset and aggressive course. Patients often present very late and have poor awareness and limited access to services with limited treatment options to lower the intraocular pressure. …

    lshtm Repository record for Adapted Motivational Interviewing to improve uptake of glaucoma treatment in Bauchi, Nigeria (opens in a new tab)

  4. Self-Adjustable Valve for Glaucoma Treatment: From Concept to First-in-Human Validation

    Glaucoma drainage devices (GDDs) are implantable shunts designed to lower intraocular pressure (IOP) by diverting aqueous humor to a subconjunctival reservoir. However, current GDDs often struggle to (i) provide intrinsic protection against early postoperative hypotony, (ii) passively adapt to …

    epfl Repository record for Self-Adjustable Valve for Glaucoma Treatment: From Concept to First-in-Human Validation (opens in a new tab)

  5. Advanced Delivery Platforms for Netarsudil: Microneedle-Implant Devices and Suprachoroidal Nanocrystals for Glaucoma Treatment

    … lowers intraocular pressure (IOP) for glaucoma treatment. However, traditional topical administration of Netarsudil causes frequent instances of conjunctival hyperemia, which severely limits patient adherence and clinical adoptability. Furthermore, existing sustained-release ocular …

    jhu Repository record for Advanced Delivery Platforms for Netarsudil: Microneedle-Implant Devices and Suprachoroidal Nanocrystals for Glaucoma Treatment (opens in a new tab) Embargoed until 2028-05-01

  6. The effects of a new class of glaucoma treatment drug netarsudil on cellular connections of Schlemm’s canal endothelium

    BACKGROUND: Primary Open Angle Glaucoma (POAG) is a subclass of glaucoma. It is the second most common cause of blindness, within the United States. This disease is characterized by its link to one of its major risk factors, increasing intraocular pressure (IOP). High IOP causes neuronal death of …

    bu Repository record for The effects of a new class of glaucoma treatment drug netarsudil on cellular connections of Schlemm’s canal endothelium (opens in a new tab)

  7. High intensity focused ultrasound in ophthalmology : part one, transscleral drug delivery : part two, infrared thermography for scalable acoustic characterization, an application in the manufacture of a glaucoma treatment device

    Les ultrasons (US) thérapeutiques sont devenus un sujet d'intérêt croissant en ophtalmologie. Les ultrasons focalisés de haute intensité (HIFU) pour le traitement du glaucome et pour la délivrance de médicaments dans l'oeil sont les deux principaux domaines de recherche dans ce domaine. Cette thèse …

    star-france Repository record for High intensity focused ultrasound in ophthalmology : part one, transscleral drug delivery : part two, infrared thermography for scalable acoustic characterization, an application in the manufacture of a glaucoma treatment device (opens in a new tab)

  8. Evaluating Lipidomic Circuit Modulation in Glaucoma Management

    Glaucoma, a sight-threatening condition, is primarily characterized by elevated intraocular pressure (IOP). Despite its importance, the relationship between IOP and glaucoma progression is complex. Livne-Bar et al. (2017) unveiled the neuroprotective potential of lipoxins A4 and B4 (LXA4 and LXB4) …

    toronto-retro Repository record for Evaluating Lipidomic Circuit Modulation in Glaucoma Management (opens in a new tab)

  9. Glaucoma drainage devices: design, flow resistance and biocompatibility implications for intraocular pressure control

    … aim of this thesis is to develop a novel glaucoma drainage device that meets the ‘10-10-10’ goal for glaucoma treatment: specifically, a surgical intervention that can reduce the intraocular pressure to 10mmHg, can be implanted in 10 minutes and lasts for 10 years. The thesis encompasses …

    ucl Repository record for Glaucoma drainage devices: design, flow resistance and biocompatibility implications for intraocular pressure control (opens in a new tab)

  10. Bridging the Gap Between Biomechanics and Modern Computer Architecture: Analyzing Bottlenecks in a Human Eye Simulation

    … finite element model of the human eye, from the glaucoma treatment study that inspired this project, provides a practical demonstration of FEBio’s computational behavior under realistic conditions. By identifying performance bottlenecks, analyzing their underlying causes, and proposing potential …

    maryland Repository record for Bridging the Gap Between Biomechanics and Modern Computer Architecture: Analyzing Bottlenecks in a Human Eye Simulation (opens in a new tab)

  11. Trends In The Utilization of Antiglaucoma Medication: An Analysis of Canadian Drug Insurance Claims

    … To assess: i) utilization of generic anti-glaucoma drugs in Canada; ii) the impact of the 2010 Ontario Drug System Reform on generic anti-glaucoma drug usage in Ontario. Methods: Monthly drug insurance cost and claims from January 2001 to January 2013 were used as proxies for drug …

    uwo Repository record for Trends In The Utilization of Antiglaucoma Medication: An Analysis of Canadian Drug Insurance Claims (opens in a new tab)

  12. Improving Compliance via Education, Reminders, and Evaluating Physician-Patient Concerns in Glaucoma

    PURPOSE: To improve glaucoma treatment compliance via education, medication reminders, and understanding of patient and physician concerns. DESIGN: Prospective Comparative Case Series SUBJECTS: 194 consecutive eligible patients diagnosed with primary open angle glaucoma or ocular hypertension at a …

    utswmed Repository record for Improving Compliance via Education, Reminders, and Evaluating Physician-Patient Concerns in Glaucoma (opens in a new tab)

  13. Desenvolvimento de implantes biodegradáveis constituídos de copolímero dos ácidos lático e glicólico e losartan

    Glaucoma is the second cause of vision loss around the world and it is mainly developed by elevate intraocular pressure. The glaucoma treatment in the majority of patients starts with drugs, but some of them continue losing vision, which becomes necessary the filtering surgery. The success of the …

    brazil-ufmg Repository record for Desenvolvimento de implantes biodegradáveis constituídos de copolímero dos ácidos lático e glicólico e losartan (opens in a new tab)

  14. The validity and reliability of intraocular pressure measurement using rebound tonometry in children with ocular and systemic disease

    … Fifty children were recruited, including 34 with glaucoma for objectives 1 and 2 and 16 for objective 3 (8 HCTDs, 8 healthy controls).Interventions: RBT measurements were taken at the geometric centre of the cornea of one eye (RBTon) and at 3 mm temporally (RBToff), followed by Goldmann tonometry …

    aston Repository record for The validity and reliability of intraocular pressure measurement using rebound tonometry in children with ocular and systemic disease (opens in a new tab)

  15. RISK OF CANCER AND OCULAR DISEASES FOLLOWING CT SCANS

    … to 2023, we evaluated the risk of cataract and glaucoma in relation to radiation dose to the eye lens following head CT scans. Analyses based on cataract surgery, glaucoma diagnosis, or glaucoma treatment, lagged by 3, 5, and 7 years, showed no increased risk due to radiation exposure. …

    mcmaster Repository record for RISK OF CANCER AND OCULAR DISEASES FOLLOWING CT SCANS (opens in a new tab)

  16. Patterns of Medication Adherence in Glaucoma

    … globally are affected by primary open angle glaucoma (POAG)—an optic neuropathy characterized by distinctive patterns of vision loss. Glaucoma is a leading cause of irreversible blindness worldwide, and eye drops that delay vision loss are a common treatment modality. In glaucoma, the …

    uab Repository record for Patterns of Medication Adherence in Glaucoma (opens in a new tab)

Page 1 of 2