Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 150 for “"Gleeble"”.

  1. Superalloy Metallurgy a Gleeble Study of Environmental Fracture in Inconel 601

    … properties with unexpected early failure. The Gleeble is a valuable tool for investigation and simulation of thermo-mechanical properties of an alloy in various regimes up to the threshold of melting. In this study, four regimes of temperature and strain rate were simulated in an argon …

    calpoly Repository record for Superalloy Metallurgy a Gleeble Study of Environmental Fracture in Inconel 601 (opens in a new tab)

  2. Estudo das deformações em ensaio de compressão plana no simulador físico Gleeble

    … valores de deformação programados via simulador Gleeble nos corpos de prova envolvidos nos ensaios.

    brazil-ufrgs Repository record for Estudo das deformações em ensaio de compressão plana no simulador físico Gleeble (opens in a new tab)

  3. A Quantitative Study of the Weldability of Inconel 718 Using Gleeble and Varestraint Test Methods

    … 718 was tested and compared to Haynes 230 using Gleeble and Varestraint mechanical test methods. Hot cracking susceptibility was examined in either alloy using a sub-scale Varestraint test method at 5 augmented strain levels: 0.25%, 05.%, 1%, 2%, and 4%. Maximum crack length, total crack length, …

    calpoly Repository record for A Quantitative Study of the Weldability of Inconel 718 Using Gleeble and Varestraint Test Methods (opens in a new tab)

  4. The Viability of using a Gleeble for Physical Simulation of High Frequency Induction Welded TRIP 690 AHSS

    … process in thin sheets of TRIP 690 AHSS using a Gleeble 3500 thermomechanical simulator. The results of this work demonstrated that the Gleeble could reproduce the microstructure across the bond line and heat affected zone of the HFIW produced welds. Mechanical characterization of the welds …

    waterloo Repository record for The Viability of using a Gleeble for Physical Simulation of High Frequency Induction Welded TRIP 690 AHSS (opens in a new tab)

  5. Characterization of Inconel 718: Using the Gleeble and Varestraint Testing Methods to Determine the Weldability of Inconel 718

    … to actual fabrication. These are the Gleeble hot-ductility test and the Variable-Restraint (Varestraint) weld test. Varestraint samples were prepared as per standard preparation techniques and tested longitudinally with a GTAW. At a predetermined location a strain was applied …

    calpoly Repository record for Characterization of Inconel 718: Using the Gleeble and Varestraint Testing Methods to Determine the Weldability of Inconel 718 (opens in a new tab)

  6. Mathematical modelling of the high temperature constitutive behaviour of as-cast AA5182 aluminum alloy

    … compression-tension tests were done using the Gleeble 1500 thermomechanical simulator at the University of British Columbia to measure the constitutive behaviour in an as-cast AA5182 aluminum alloy. The temperatures (i.e., 250-500°C) and strain rates (1E-5 – 1s⁻¹) used for the tests were chosen …

    ubc Repository record for Mathematical modelling of the high temperature constitutive behaviour of as-cast AA5182 aluminum alloy (opens in a new tab) Download PDF for Mathematical modelling of the high temperature constitutive behaviour of as-cast AA5182 aluminum alloy (opens in a new tab)

  7. An Investigation into the Austenite Decomposition Behaviour and Post-Forming Tempering Response of Two 1800 MPa Grades of Press Hardening Steels

    … of bainite, martensite, and ferrite. The Gleeble experiments were simulated using LS-Dyna and a thermal-mechanical-microstructural model. In the second investigation (Part II – Short Cycle Tempering), both steels were fully quenched in the Gleeble to produce a fully martensitic …

    guelph Repository record for An Investigation into the Austenite Decomposition Behaviour and Post-Forming Tempering Response of Two 1800 MPa Grades of Press Hardening Steels (opens in a new tab)

  8. Effect of Manganese (Mn) Content and Homogenization Treatment on Hot Deformation of AA3xxx Aluminum Alloys

    … deformation of the alloys was conducted using Gleeble 3500 machine, under plane strain conditions up to a final strain of 0.5. The deformation strain rate was selected as 0.1, 1.0 and 10 s-1, and deformation temperature was ranged between 300-500°C with 100°C temperature steps. Using the flow …

    waterloo Repository record for Effect of Manganese (Mn) Content and Homogenization Treatment on Hot Deformation of AA3xxx Aluminum Alloys (opens in a new tab)

  9. Fragilidade a têmpera em aços SAE 5160

    … e tratamentos térmicos especiais realizados na Gleeble 1500. Com o tratamento térmico convencional microestruturas martensíticas e bainítica foram obtidas. Para os aços martensíticos as temperaturas de austenitização variaram entre 830 e 1100 oC com o revenido variando entre como temperado até …

    brazil-ufrgs Repository record for Fragilidade a têmpera em aços SAE 5160 (opens in a new tab)

  10. An electron fractography (SEM)investigation of heat-affected zone in the newly developed Climax low-carbon Mn-Mo-Nb Steel

    … zone in this new steel was investigated via the Gleeble technique. The grain refined region of the heat-affected zone showed excellent toughness at impact test temperatures of as low as -60°F, the upper-shelf extending to about -25°F. The grain coarsened region showed inferior toughness, …

    ut-knoxville Repository record for An electron fractography (SEM)investigation of heat-affected zone in the newly developed Climax low-carbon Mn-Mo-Nb Steel (opens in a new tab)

  11. Evaluation of the hot cracking sensitivity of 316 NG, 347 and 304 stainless steels using the hot ductility test and the modified subscale varestraint test

    … The hot ductility test was conducted on the Gleeble using standard parameters.</p> <p>Both, the varestraint test and Gleeble test were utilized to evaluate the hot cracking susceptibility of base metal HAZ in austenitic stainless steels. In addition, the fusion zone and weld metal HAZ …

    ut-knoxville Repository record for Evaluation of the hot cracking sensitivity of 316 NG, 347 and 304 stainless steels using the hot ductility test and the modified subscale varestraint test (opens in a new tab)

  12. A study of directionally solidified Rene 80 subjected to short-term overtemperature

    … overtemperature on Rene 80 DS were studied using Gleeble thermo-mechanical simulation apparatus. Volume fraction of gamma prime to gamma matrix was quantified and used to assess the effects of time, temperature and stress. Volume fraction was found to decrease with increasing temperature and time. …

    manitoba Repository record for A study of directionally solidified Rene 80 subjected to short-term overtemperature (opens in a new tab)

  13. Characterization of the cooling and transformation of steels on a run-out table of hot-strip mill

    … of the model predicted cooling conditions on a Gleeble high temperature testing machine showed that the transformation was occurring at approximately 730°C. The empirical transformation start time, obtained from cooling rate versus transformation start time tests, which was used in the phase …

    ubc Repository record for Characterization of the cooling and transformation of steels on a run-out table of hot-strip mill (opens in a new tab) Download PDF for Characterization of the cooling and transformation of steels on a run-out table of hot-strip mill (opens in a new tab)

  14. The effect of non-metallic particles on as-cast austenitic structure of low carbon steel

    … cooling and helium quenching were performed on a Gleeble 1500 Thermo mechanical Simulator. Two low alloy types of steel were used; both had basically the same basic chemical composition, but contained different amounts of titanium and calcium. The as-cast austenite grain size was characterized in …

    ubc Repository record for The effect of non-metallic particles on as-cast austenitic structure of low carbon steel (opens in a new tab) Download PDF for The effect of non-metallic particles on as-cast austenitic structure of low carbon steel (opens in a new tab)

  15. HIGH-TEMPERATURE PHYSICO-MECHANICAL PROPERTIES OF AS-RECEIVED STRUCTURES IN DUAL-PHASE ADVANCED HIGH-STRENGTH STEELS

    … ends, high-temperature tensile tests using a Gleeble thermomechanical simulator have been conducted to determine the stress/strain behaviour at temperatures between 1250 to 1480 C in order to quantify the tensile strength and ductility. The results of both as-cast and transfer-bar material …

    mcmaster Repository record for HIGH-TEMPERATURE PHYSICO-MECHANICAL PROPERTIES OF AS-RECEIVED STRUCTURES IN DUAL-PHASE ADVANCED HIGH-STRENGTH STEELS (opens in a new tab)

  16. An Experimentally Generated Constitutive Model for Peak Stress (σ_peak) in Compression Samples

    … by hot-compression deformation tests on the Gleeble 1500 thermo-mechanical simulator at true strain values of -0.143 and -0.405, true strain rate values of 0.01 and 0.1, and working temperatures of 900°C and 1000°C. The tests show that a lower working temperature and lower true strain value …

    calpoly Repository record for An Experimentally Generated Constitutive Model for Peak Stress (σ_peak) in Compression Samples (opens in a new tab)

  17. Effect of Preheating Condition on Strength of AA6060 Aluminium Alloy for Extrusion

    … were conducted by hot compression testing (Gleeble test), to measure the combination of strengthening effects during deformation at elevated temperatures. The room temperature tests have shown that hardness, yield strength (YS) and ultimate tensile strength (UTS) are minimised at …

    auckland-tech Repository record for Effect of Preheating Condition on Strength of AA6060 Aluminium Alloy for Extrusion (opens in a new tab)

  18. Weldability and Liquid Metal Embrittlement Susceptibility of Martensitic Ultra-High Strength Steels

    … using hot ductility testing (HDT) conducted on a Gleeble thermo-mechanical simulator. Detailed analysis of the lath martensitic microstructure was performed, and it was found that there is a correlation between the microstructure and the observed LME response. It was discovered that the three MS …

    alabama Repository record for Weldability and Liquid Metal Embrittlement Susceptibility of Martensitic Ultra-High Strength Steels (opens in a new tab)

  19. Microstructure evolution during extrusion of AA3xxx aluminum alloys

    … on the recrystallization behavior. In addition, Gleeble tests were conducted on a low iron AA3102 alloy using a Gleeble 3500 Thermo-mechanical Simulator at strain rates of 0.1s-1, 1s-1 and 10s-1 and deformation temperature of 400oC, 500oC, and 600oC. The yield stress, work hardening and flow …

    ubc Repository record for Microstructure evolution during extrusion of AA3xxx aluminum alloys (opens in a new tab) Download PDF for Microstructure evolution during extrusion of AA3xxx aluminum alloys (opens in a new tab)

Page 1 of 8