Results 1 to 20 of 44 for “"Gradient Coil"”

  1. Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System

    … brain damage to potential prediction of stroke. Gradient coil and signal-to- noise ratio (SNR) constraints limit spatial resolution, accuracy, and scan time in DMRI. Achieving high b-values (measures of a scan's sensitivity to diffusion) often require scans with long diffusion gradient pulses, …

    byu Repository record for Improvements in Diffusion Weighted Imaging Through a Composite Body and Insert Gradient Coil System (opens in a new tab)

  2. Design of Transverse Gradient Coil Technology for Dynamic Manipulation of Image Volume in MRI

    … was to investigate the capabilities of a novel gradient concept for the purpose of dynamic manipulation of imaging volume and gradient performance in Magnetic Resonance Imaging (MRI). The proposed concept exploits the natural inverse co-dependence between the gradient strength of the coil …

    uwo Repository record for Design of Transverse Gradient Coil Technology for Dynamic Manipulation of Image Volume in MRI (opens in a new tab)

  3. Design of Transverse Gradient Coil Technology for Dynamic Manipulation of Image Volume in MRI

    … was to investigate the capabilities of a novel gradient concept for the purpose of dynamic manipulation of imaging volume and gradient performance in Magnetic Resonance Imaging (MRI). The proposed concept exploits the natural inverse co-dependence between the gradient strength of the coil …

    uwo Repository record for Design of Transverse Gradient Coil Technology for Dynamic Manipulation of Image Volume in MRI (opens in a new tab)

  4. Ultra fast MRI acquisition at 7 Tesla: Implementation of Wave-CAIPI with a high efficiency head insert gradient coil

    … On the hardware side, a highly efficient insert gradient coil has been designed and built at the University Medical Center Utrecht. Specialized software has to be implemented to optimally make use of this hardware. One of the recently proposed PI methods called Wave-CAIPI has been proved to …

    delft Repository record for Ultra fast MRI acquisition at 7 Tesla: Implementation of Wave-CAIPI with a high efficiency head insert gradient coil (opens in a new tab)

  5. Magnetic Resonance Systems Development for Point-of-Care MRI Platforms

    … This is overcome by designing asymmetric gradient coils which have their imaging region located towards one end of the gradient coil, as opposed to the geometric center, allowing brain imaging. There exists interest in compact configurations which allow imaging further into the cervical …

    uwo Repository record for Magnetic Resonance Systems Development for Point-of-Care MRI Platforms (opens in a new tab)

  6. Magnetic field issues in magnetic resonance imaging

    … over a prescribed imaging volume. In the gradient coil, the entire design for the axial elliptical coil, and the mathematical foundation for the transverse elliptical coil have been presented. Also, the design of a self-shielded cylindrical gradient coil with a restricted length has been …

    ohiolink Repository record for Magnetic field issues in magnetic resonance imaging (opens in a new tab)

  7. Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns

    A fourth gradient channel was implemented to provide slice dependent RF coil phase compensation for arrays in dual-sided or "sandwich" configurations. The use of highly parallel arrays for single echo acquisition magnetic resonance imaging allows both highly accelerated imaging and capture of …

    tamu Repository record for Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns (opens in a new tab)

  8. Comparison of Human Peripheral Nerve Stimulation Thresholds as Measured using Electric and Magnetic Stimuli: Relevance to MRI Gradient Safety

    … from the rapidly changing magnetic fields of gradient coils is a concern. Nerves exposed to either electric fields or time-varying magnetic fields would be expected to display consistent threshold characteristics, motivating the direct application of electric field exposure criteria from …

    uwo Repository record for Comparison of Human Peripheral Nerve Stimulation Thresholds as Measured using Electric and Magnetic Stimuli: Relevance to MRI Gradient Safety (opens in a new tab)

  9. Reducing Acoustic Noise in MRI Scanners

    … of generalized radiation impedances of gradient coil ducts with perforated panel inserts were developed and the effects of the perforated panel inserts on the acoustic noise in the duct were discussed. The possibility of using micro-perforated panel (MPP) absorbers in MRI scanners to …

    queens Repository record for Reducing Acoustic Noise in MRI Scanners (opens in a new tab)

  10. Development and applications of a highly flexible nonlinear spatial encoding system for magnetic resonance imaging

    … to design, implement and test a shielded matrix gradient coil for magnetic resonance imaging (MRI).<br><br>The design process addressed gradient strength, flexibility, magnetic shielding, cooling, electrical decoupling, balance of force and torque and patient safety. These demands were fulfilled …

    freiburg-diss Repository record for Development and applications of a highly flexible nonlinear spatial encoding system for magnetic resonance imaging (opens in a new tab)

  11. Applications of rheo-NMR-microscopy to complex fluids : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Physics at Massey University

    … polymer side branch length, were also studied. Gradient coil developments are also described in detail. Linearity, homogeneity and screening conditions are investigated for a transverse quadrupole-target-field gradient coil. The need for large gradients are discussed with the implications to …

    massey Repository record for Applications of rheo-NMR-microscopy to complex fluids : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Physics at Massey University (opens in a new tab)

  12. Indirect Detection of Axonal Architecture With Q-Space Imaging

    … morphology. First, a custom-built high-amplitude gradient coil was used to address the limitations in the maximum gradient amplitude available with commercial systems. Second, to understand the relationship between axon morphology and QSI, simulations were used to investigate the effects of the …

    penn Repository record for Indirect Detection of Axonal Architecture With Q-Space Imaging (opens in a new tab)

  13. The electrodynamics of gradient fields in superconductive magnetic resonance imaging systems

    … current problem associated with magnetic field gradients in superconductive magnetic resonance imaging (MRI) and spectroscopy (MRS) applications is well-known throughout the nuclear magnetic resonance (NMR) scientific and engineering community. The electromagnetic interaction of gradient field …

    ohiolink Repository record for The electrodynamics of gradient fields in superconductive magnetic resonance imaging systems (opens in a new tab)