Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 118 for “"Gradient elution"”.

  1. Rapid Detection of Biogenic Amines using Capillary Electrophoresis and Gradient Elution Isotachophoresis

    … for sensitive neurotransmitter measurements, gradient elution isotachophoresis. Gradient elution isotachophoresis is an efficient capillary-based enrichment and separation technique based on balancing hydrodynamic counter-flow against electrophoresis. Enrichment is achieved with the aid of …

    temple Repository record for Rapid Detection of Biogenic Amines using Capillary Electrophoresis and Gradient Elution Isotachophoresis (opens in a new tab)

  2. Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS

    <p>The groundwork for coupling gradient liquid chromatography (LC) with inductively coupled plasma mass spectrometry (ICP-MS) is developed. An alternative method of quantification to isotope dilution is evaluated. Using a micronebulizer (100 [Mu]L/min) and the Apex-Q desolvation system from …

    iastate Repository record for Reduction of solvent effect in reverse phase gradient elution LC-ICP-MS (opens in a new tab)

  3. CONCENTRATION ENHANCEMENT AND DEVICE FABRICATION FOR THE IMPROVED PERFORMANCE OF GRADIENT ELUTION MOVING BOUNDARY ELECTROPHORESIS

    … the methods of analysis performed with them. Gradient elution moving boundary electrophoresis (GEMBE) is a recently described counterflow electrophoresis method that was developed to simplify the analysis of ions in complex matrices. In this thesis, the improvement of the limit of detection of …

    maryland Repository record for CONCENTRATION ENHANCEMENT AND DEVICE FABRICATION FOR THE IMPROVED PERFORMANCE OF GRADIENT ELUTION MOVING BOUNDARY ELECTROPHORESIS (opens in a new tab)

  4. Interfacing of an LSI-11 micro processor with the spectra-physics 3500B gradient elution liquid chromatograph

    … and a Spectra-Physics model 3500B gradient elution liquid chromatography were interfaced for the purpose of automating the chromatograph, incorporating it into the laboratory data network system and collecting data for Michael Starlings' project. The automation involved the …

    vt Repository record for Interfacing of an LSI-11 micro processor with the spectra-physics 3500B gradient elution liquid chromatograph (opens in a new tab)

  5. Development of a Novel Capillary Based pH Gradient Elution Moving Boundary Electrophoresis Method and Electrolysis Free Device for Protein Separation and Concentration

    … at the micron scale. The new method, termed pH gradient elution moving boundary electrophoresis (pHGEMBE), separates proteins based on their isoelectric point (pI). The technique was inspired by the high resolution capabilities of isoelectric focusing (IEF), combined with the counter-flow …

    waterloo Repository record for Development of a Novel Capillary Based pH Gradient Elution Moving Boundary Electrophoresis Method and Electrolysis Free Device for Protein Separation and Concentration (opens in a new tab)

  6. Interactive, user-directed, computer-assisted HPLC methods development

    … approach for determining multi-segment gradient elution profiles for High Performance Liquid Chromatography (HPLC) is presented. The approach is based on determining the gradient segment necessary to elute each solute at a user specified retention time. There are five main functions of …

    unh-thes Repository record for Interactive, user-directed, computer-assisted HPLC methods development (opens in a new tab)

  7. Optimization of ion-exchange chromotography with multiple gradient inputs for protein separations

    Gradient elution chromatography is an efficient technique for adjusting the retention of sample components during liquid chromatographic separations. However, the optimization of gradient elution is usually done by trial and error. Thus, for large scale processes this results in expensive and time …

    njit Repository record for Optimization of ion-exchange chromotography with multiple gradient inputs for protein separations (opens in a new tab)

  8. Measuring Kinetic Performance of Monolithic and Fused-Core Columns Using Packed-Capillary Liquid-, Ultrahigh-Performance- and Supercritical Fluid Chromatography

    … KPM method can be used for both isocratic and gradient elution and is useful in the comparison of different types of chromatographies (HPLC, GC, CEC, SFC). The KPM was used to compare the performance of packed-capillary (0.2 and 0.3 mm) and microbore (2.0 and 2.1 mm) superficially porous and …

    sdstate Repository record for Measuring Kinetic Performance of Monolithic and Fused-Core Columns Using Packed-Capillary Liquid-, Ultrahigh-Performance- and Supercritical Fluid Chromatography (opens in a new tab)

  9. Μοντελοποιήσεις και προσομοιώσεις υγροχρωματογραφικών δεδομένων για εκπαιδευτικούς και ερευνητικούς σκοπούς

    … optimization under isocratic and/or under simple gradient conditions as well as under multilinear gradient conditions in single or double gradient elution mode by changing organic modifier(s) content and/or eluent pH. The whole chromatographic separation optimization process by MS Excel can be …

    greece Repository record for Μοντελοποιήσεις και προσομοιώσεις υγροχρωματογραφικών δεδομένων για εκπαιδευτικούς και ερευνητικούς σκοπούς (opens in a new tab)

  10. Electrochemical detection methods for biologically-active molecules

    … separation of nearly all amino acids using gradient elution liquid chromatography;Improvement in detection of underivatized amino acids was made by applying Pulsed Coulometric Detection (PCD) and Indirect Coulometric Adsorption Detection (ICAD). Both could be used following separation on …

    iastate Repository record for Electrochemical detection methods for biologically-active molecules (opens in a new tab)

  11. The Combination of Microbore Liquid Chromatography and Mass Spectrometry

    … the system was tested under both isocratic and gradient elution conditions, using a standard mixture of 16 polycyclic aromatic hydrocarbons (PAH).</p> <p> The microbore column HPLC was also coupled to a mass spectrometer equipped with a moving belt interface. Chromatographic performance under …

    mcmaster Repository record for The Combination of Microbore Liquid Chromatography and Mass Spectrometry (opens in a new tab)

  12. Separation and Characterization of Variant Forms of Phosphoglucose Isomerase: Purification and Structural Analysis of Active Site Peptides from Human and Rabbit Phosphoglucose Isomerase

    … of the enzyme. The method utilizes a substrate gradient elution of the enzyme from carboxymethyl Biogel and is far superior in terms of resolution and recovery to methods based on electrophoresis and isoelectric focusing. Four different genetic variant forms of the enzyme were isolated and …

    unt Repository record for Separation and Characterization of Variant Forms of Phosphoglucose Isomerase: Purification and Structural Analysis of Active Site Peptides from Human and Rabbit Phosphoglucose Isomerase (opens in a new tab)

  13. Radio-Frequency Sensors for High Performance Liquid Chromatography Applications

    … of high sensitivity, universal detection and gradient-elution compatibility is highly desired. In this dissertation, two types of radio-frequency (RF) sensors for HPLC gradient applications are presented: a tunable interferometer (TIM) and a modified square ring loaded resonator (SRLR). For …

    clemson Repository record for Radio-Frequency Sensors for High Performance Liquid Chromatography Applications (opens in a new tab)

  14. Practical, Scalable, and Cost-Effective nanoLC-MS Workflow for Single-Cell Proteomics

    … However, traditional ultra-low flow rate gradient elution relies on high-pressure binary pumps and splitting systems, which not only have high hardware costs but also introduce flow rate fluctuations and gradient instability. Simultaneously, narrow-bore chromatographic columns are prone to …

    byu Repository record for Practical, Scalable, and Cost-Effective nanoLC-MS Workflow for Single-Cell Proteomics (opens in a new tab) Download PDF for Practical, Scalable, and Cost-Effective nanoLC-MS Workflow for Single-Cell Proteomics (opens in a new tab)

  15. Polymeric Monolithic Stationary Phases for Capillary Reversed-phase Liquid Chromatography of Small Molecules

    … was investigated in detail. Isocratic elution of alkylbenzenes at a flow rate of 300 nL/min was conducted for all of the monoliths. Gradient elution of alkylbenzenes and alkylparabens provided high resolution separations. Several of the monoliths demonstrated column efficiencies in …

    byu Repository record for Polymeric Monolithic Stationary Phases for Capillary Reversed-phase Liquid Chromatography of Small Molecules (opens in a new tab) Download PDF for Polymeric Monolithic Stationary Phases for Capillary Reversed-phase Liquid Chromatography of Small Molecules (opens in a new tab)

Page 1 of 6