Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 75 for “"Graphite electrode"”.

  1. Graphite Electrode Characterization on the ZaP-HD Sheared-Flow-Stabilized Z-Pinch Device

    … environment for a prolonged duration. The inner electrode is exposed to the plasma while forming a part of the discharge current path, resulting in significant erosion of the tungsten-sprayed copper nose cone and contamination of the plasma. A graphite nose cone was installed to investigate its …

    washington Repository record for Graphite Electrode Characterization on the ZaP-HD Sheared-Flow-Stabilized Z-Pinch Device (opens in a new tab)

  2. Polianilino ir pilipirolo, aukso nanodalelių bei įvairių elektronų pernašos tarpininkų taikymas gliukozės biologiniuose jutikliuose /

    … layer to cover the glucose oxidase modified graphite electrode surface and synthesis of glucose oxidase and gold nanoparticles embedded in a layer of polyaniline nanocomposite structures. Key analytical characteristics of glucose biosensor modified by nanocomposite structures were analyzed …

    vilnius Repository record for Polianilino ir pilipirolo, aukso nanodalelių bei įvairių elektronų pernašos tarpininkų taikymas gliukozės biologiniuose jutikliuose / (opens in a new tab)

  3. Polianilino ir polipirolo, aukso nanodalelių bei įvairių elektronų pernašos tarpininkų taikymas gliukozės biologiniuose jutikliuose /

    … layer to cover the glucose oxidase modified graphite electrode surface and synthesis of glucose oxidase and gold nanoparticles embedded in a layer of polyaniline nanocomposite structures. Key analytical characteristics of glucose biosensor modified by nanocomposite structures were analyzed …

    vilnius Repository record for Polianilino ir polipirolo, aukso nanodalelių bei įvairių elektronų pernašos tarpininkų taikymas gliukozės biologiniuose jutikliuose / (opens in a new tab)

  4. Aukso nanodalelių ir π-π konjuguoto polimero polipirolo taikymas gliukozės biologiniuose jutikliuose /

    … achievement of enzymes direct wiring to electrode surface. Also, nanoparticles increase electron transfer rate between enzyme and an electrode surface. The aim of the work was to to apply different size nanoparticles, different glucose oxidases and electroconductive polymer polypyrrole …

    vilnius Repository record for Aukso nanodalelių ir π-π konjuguoto polimero polipirolo taikymas gliukozės biologiniuose jutikliuose / (opens in a new tab)

  5. Aukso nanodalelių ir π-π konjuguoto polimero polipirolo taikymas gliukozės biologiniuose jutikliuose /

    … achievement of enzymes direct wiring to electrode surface. Also, nanoparticles increase electron transfer rate between enzyme and an electrode surface. The aim of the work was to to apply different size nanoparticles, different glucose oxidases and electroconductive polymer polypyrrole …

    vilnius Repository record for Aukso nanodalelių ir π-π konjuguoto polimero polipirolo taikymas gliukozės biologiniuose jutikliuose / (opens in a new tab)

  6. ELECTROCHEM-MECHANICS CHARACTERIZATION OF SI ELECTRODE/SI BASED SOLID-STATE BATTERY

    … but the energy density of current LIBs with graphite electrode doesn’t suffice the need of long driving range. Replacing graphite electrode with alloying type electrodes that have almost ten times higher energy density is thus a necessary route to improve the energy density of LIBs. However, …

    maryland Repository record for ELECTROCHEM-MECHANICS CHARACTERIZATION OF SI ELECTRODE/SI BASED SOLID-STATE BATTERY (opens in a new tab)

  7. Experimental and Computational Study of Flow Fields in Porous Electrodes for the Vanadium Flow Battery

    … thesis, advanced flow field patterned modified graphite porous electrodes were produced using an embroidery method. The battery performance and electrolyte distribution were analysed for various embroidered designs on 100 mm x 100 mm graphite felt electrodes. Flow visualisation tests …

    unsw Repository record for Experimental and Computational Study of Flow Fields in Porous Electrodes for the Vanadium Flow Battery (opens in a new tab)

  8. METAL ION SEPARATION USING ELECTRICALLY SWITCHED ION EXCHANGE

    … film that is deposited onto a conductive electrode surface. Typically, for Cs+ removal, this film is composed of nickel hexacyanoferrate, which is known for its selectivity for that ion. The ESIX method involves the sequential application of reduction and oxidation potentials to an ion …

    mcmaster Repository record for METAL ION SEPARATION USING ELECTRICALLY SWITCHED ION EXCHANGE (opens in a new tab)

  9. The development of electrochemical sensors based on the use of different forms of carbon materials

    … thesis, carbon based materials such as pyrolytic graphite; carbon nanotubes and carbon fibre have been used for a number of analytical and fundamental investigations. The first research aim of this thesis is to develop sensors for the detection of chemical compounds in ginger and turmeric. Chapter …

    oxford Repository record for The development of electrochemical sensors based on the use of different forms of carbon materials (opens in a new tab)

  10. An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma

    … immunoassay system based on simple graphite electrode arrays, 3D-printed flow cells, and signal-generating magnetic bead bioconjugates for simultaneous detection of three biomarker proteins (cancer antigen 125 (CA-125), midkine (MK) and osteopontin (OPN)) associated with pediatric …

    etsu Repository record for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab) Download PDF for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab)

  11. Electrochemistry of methylated pterins :

    … rise to three oxidation peaks at the pyrolytic graphite electrode. Peak I(, a) is an almost reversible 2e-2H('+) oxidation reaction to an unstable quinonoid-dihydropterin. Based on electrochemical, spectroelectrochemical and kinetic results it is believed that this intermediate has an ortho …

    oklahoma-thes Repository record for Electrochemistry of methylated pterins : (opens in a new tab)

  12. Electrochemiluminescence using Pencil Graphite Electrodes and Screen-printed Carbon Electrodes Interfaced with a Simple Imaging System

    … interfaced with a zoom lens to compare pencil graphite electrode (PGE) and screen-printed carbon electrode (SPCE) arrays as ECL platforms. With this system, ECL signals generated from tris(2,2′- bipyridine)ruthenium(II) chloride hexahydrate ([Ru(bpy)3]2+) using co-reactant tri-n-propylamine …

    etsu Repository record for Electrochemiluminescence using Pencil Graphite Electrodes and Screen-printed Carbon Electrodes Interfaced with a Simple Imaging System (opens in a new tab) Download PDF for Electrochemiluminescence using Pencil Graphite Electrodes and Screen-printed Carbon Electrodes Interfaced with a Simple Imaging System (opens in a new tab)

  13. A Multi-Pronged, Noninvasive Probing of Electrodeposition in Li-Ion Batteries

    … This deposition builds up on the surface of the graphite electrode and can lead to the formation of structures called dendrites. These dendrites can cause problems like internal short-circuits, ultimately resulting in the battery catching on fire. The focus of this work is to study the …

    tamu Repository record for A Multi-Pronged, Noninvasive Probing of Electrodeposition in Li-Ion Batteries (opens in a new tab)

  14. Optical Properties of Lithiated Graphite In Relation to a Lithium Ion Battery Fiber Optic Sensor

    … battery material changes during operation. Graphite is the most commonly used anode material and its phenomenal optical changes, which has fascinated many researchers, has inspired this research work and supported the development of a new type of electric battery cell sensor that utilizes an …

    waterloo Repository record for Optical Properties of Lithiated Graphite In Relation to a Lithium Ion Battery Fiber Optic Sensor (opens in a new tab)

  15. Electromechanical interactions in lithium-ion batteries: Aging effects and analytical use

    … fade rate is moderate but some areas of the graphite electrode degrade faster than others. Still, the localized changes are hardly noticeable on cell level due to averaging effects. Lithium plating occurs first in unevenly compressed areas, creating patterns visible to the human eye. As …

    wurz-thes Repository record for Electromechanical interactions in lithium-ion batteries: Aging effects and analytical use (opens in a new tab)

  16. Electrochemical Nucleation of Lithium on Copper

    … and higher specific energies. By replacing the graphite electrode material in today’s widespread lithium-ion batteries with lithium (Li) metal, the energy density of the cell can be doubled, from 600Wh L−1 to 1200Wh L−1 , and the specific en ergy of the cell can be increased from 250Wh kg−1 to …

    chalmers Repository record for Electrochemical Nucleation of Lithium on Copper (opens in a new tab)

Page 1 of 4