Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Grating Monochromator"”

  1. Photoelectron Spectroscopy at a Free–Electron Laser

    … as time–resolved PES experiments at the plane grating monochromator beamline PG2 at the free-electron laser (FEL) in Hamburg. Existing as well as newly developed systems for online monitoring of FEL pulse intensities and generating spatial and temporal overlap of FEL and optical laser pulses …

    cau-kiel Repository record for Photoelectron Spectroscopy at a Free–Electron Laser (opens in a new tab)

  2. Application of an 8080A microprocessor in an infrared spectroreflectometer data acquisition and processing system

    … generate and process data from an integrating sphere spectroreflectometer. The generation of the data consists of mechanically scanning a grating monochromator through specified wavelength intervals, while simultaneously measuring and storing signals from an infrared detector. The data …

    ut-knoxville Repository record for Application of an 8080A microprocessor in an infrared spectroreflectometer data acquisition and processing system (opens in a new tab)

  3. A novel cryogenic Fabry-Pérot interferometer for far-infrared astronomy

    … instrument which will employ a medium resolution grating-based spectrometer, with an optional high-resolution module. While a Martin-Puplett Fourier transform spectrometer was ultimately selected for the high-resolution module, an initial design was a Fabry-P\'{e}rot interferometer This thesis …

    lethbridge Repository record for A novel cryogenic Fabry-Pérot interferometer for far-infrared astronomy (opens in a new tab)

  4. A grating-tunable external-cavity laser based on a semiconductor laser diode

    … The external reflector used is a diffraction grating operating in the Littrow geometry. The collimated first order diffracted beam is focused on the antireflection coated facet of a British Telecom Research Laboratory 1 3fjm laser chip 55cm away. The cavity has been characterised using a lm …

    dcu Repository record for A grating-tunable external-cavity laser based on a semiconductor laser diode (opens in a new tab)

  5. Estudo dos efeitos fotoinduzidos em filmes finos calcôgenicos submetidos a luz ultravioleta de vácuo

    … de vácuo na linha de luz TGM (Toroidal Grating Monochromator) no Laboratório Nacional de Luz Síncrotron - LNLS. Apresentamos os resultados da caracterização estrutural, composicional e elétrica das ligas Sb50Te50 e Te24In38Sb38 calcogênicas na forma de pós e filmes finos. Para tal foram …

    brazil-ufsc Repository record for Estudo dos efeitos fotoinduzidos em filmes finos calcôgenicos submetidos a luz ultravioleta de vácuo (opens in a new tab)

  6. Design, construction, and calibration of a portable short wave infrared spectroradiometer

    … a non-scanning concave holographic diffraction grating with flat focal field imaged onto a 1024-element liquid-nitrogen-cooled PtSi linear-array detector. The combination of concave grating and linear-array detector was chosen in preference to Fourier transform, Hadamard transform, and scanned …

    arizona-thes Repository record for Design, construction, and calibration of a portable short wave infrared spectroradiometer (opens in a new tab)

  7. Optical power measurements : applications in fiber optics and ultraviolet radiometry

    … optic power measurements, consisting of an integrating sphere and an InGaAs photodiode, has been characterized for measurements at power levels up to 200 mW. Further characterizations have extended the power range up to 650 mW. The measurement uncertainty of the detector is 0.8% at 1-mW level …

    aalto Repository record for Optical power measurements : applications in fiber optics and ultraviolet radiometry (opens in a new tab)

  8. Modeling and Characterization of Polycrystalline Mercuric Iodide Radiation Detectors

    … a tungsten-halogen lamp and an Oriel 1/4m grating monochromator are used as a light source. The incident flux on the sample is determined using a Si photodiode as reference. Device performance for both single crystal as well as polycrystalline films is documented. We have attempted to …

    usf Repository record for Modeling and Characterization of Polycrystalline Mercuric Iodide Radiation Detectors (opens in a new tab)

  9. Entwicklung eines hybrid-integrierten Gitterspektrometers basierend auf einem mikro-opto-elektro-mechanischen Bauelement

    … the development of a hybrid-integrated scanning grating spectrometer based on a micro-opto-electro-mechanical device or a micro-opto-electromechanical system, respectively. Features of spectral measurement system to be emphasized are a miniaturized construction with the volume of about a sugar …

    qucosa-diss Repository record for Entwicklung eines hybrid-integrierten Gitterspektrometers basierend auf einem mikro-opto-elektro-mechanischen Bauelement (opens in a new tab)

  10. An investigation of the optical absorption properties of silicon as related to its electrical conductivity

    … izing angle was measured. A Bausch and Lomb Grating Monochromator and a Tungsten light source was used for the monochromatic source ( +/- 1 A at the 50% intensity points). The incident monochromatic light beam was collimated, chopped mechanically by a chopper wheel to produce 3600 HZ, and …

    njit Repository record for An investigation of the optical absorption properties of silicon as related to its electrical conductivity (opens in a new tab)