  1. Spatial phase measurement techniques in modified grating interferometry

    High sensitivity grating interferometry has become an important method in experimental mechanics to measure, with submicron sensitivity, the in-plane displacements of nearly flat objects under load. This study looks to extend the use of this interferometric setup through specific modifications to …

    arizona-thes Repository record for Spatial phase measurement techniques in modified grating interferometry (opens in a new tab)

  2. Single-Grating Interferometry in Scanning Transmission Electron Microscopy

    … which uses a single pre-specimen diffraction grating as a beamsplitter to form an N-beam electron interferometer. STEMH can recover absolute and linear phase contrast, especially at the low spatial frequencies existing techniques fail at. However, its multiple-beam illumination of the sample …

    oregon Repository record for Single-Grating Interferometry in Scanning Transmission Electron Microscopy (opens in a new tab)

  3. Application of X-ray Grating Interferometry to Polymer/Flame Retardant Blends in Additive Manufacturing

    X-ray grating interferometry is a nondestructive tool for visualizing the internal structures of samples. Image contrast can be generated from the absorption of X-rays, the change in phase of the beam and small-angle X-ray scattering (dark-field). The attenuation and differential phase data …

    lsu-thes Repository record for Application of X-ray Grating Interferometry to Polymer/Flame Retardant Blends in Additive Manufacturing (opens in a new tab)

  4. In-line phase contrast and grating interferometry at a liquid-metal-jet source with micrometer resolution

    … phase contrast or in-line phase contrast and the grating interferometry. While in-line phase contrast - under certain conditions - shows edge enhancement at interfaces due to interference, phase contrast in the grating interferometry is only indirectly measurable by the use of several gratings. In …

    wurz-thes Repository record for In-line phase contrast and grating interferometry at a liquid-metal-jet source with micrometer resolution (opens in a new tab)

  5. Visualisation of magnetic domain structures and magnetisation processes in Goss-oriented, high permeability steels using neutron grating interferometry

    … cannot be obtained. In this thesis, the neutron grating interferometer (nGI) is used to investigate the domain structures in Goss-oriented (GO) electrical steels at the Swiss Spallation Neutron Source using the cold neutron imaging facility ICON. In contrast to the attenuation based transmission …

    epfl Repository record for Visualisation of magnetic domain structures and magnetisation processes in Goss-oriented, high permeability steels using neutron grating interferometry (opens in a new tab)

  6. Use of X-ray K-edge Tomography and Interferometry Imaging Techniques for the Studies of Brominated Flame Retardants

    … as X-ray K-edge absorption tomography and X-ray grating interferometry. The UL 94 burn test is initially performed to assess the flammability behavior of flame retardant samples before X-ray imaging methods of burnt and pristine polymer blends. Because the UL 94 test bars are formulated with …

    lsu-thes Repository record for Use of X-ray K-edge Tomography and Interferometry Imaging Techniques for the Studies of Brominated Flame Retardants (opens in a new tab)

  7. Contributions expérimentales et théoriques aux techniques de contraste de phase pour l'imagerie médicale par rayons X

    … (PBI), la analyzer-based imaging (ABI) et la grating interferometry (GIFM), et d'étudier leur potentiel et la meilleure implémentation pratique pour les applications médicales. Une partie importante de cette Thèse est dédiée à l'utilisation d'algorithmes mathématiques pour l'extraction, à …

    star-france Repository record for Contributions expérimentales et théoriques aux techniques de contraste de phase pour l'imagerie médicale par rayons X (opens in a new tab)

  8. Workflows For X-ray And Neutron Interferometry/Tomography As Applied To Additive Manufacturing

    Grating-based interferometry/tomography is being rapidly developed for non-destructive evaluation of additive manufacturing test articles. An application requiring an efficient workflow is extremely necessary for stress and fatigue testing samples. At present, scientific workflows play an important role …

    lsu-thes Repository record for Workflows For X-ray And Neutron Interferometry/Tomography As Applied To Additive Manufacturing (opens in a new tab)

  9. Theory, Experiments, and Image Recovery Algorithms for X-ray Interferometry

    Purpose: X-ray grating interferometry is a form of X-ray phase contrast imaging capable of simultaneously measuring attenuation, differential-phase, and dark-field images arising from X-ray absorption, refraction, and small-angle scattering, respectively. These additional contrast mechanisms have …

    lsu-thes Repository record for Theory, Experiments, and Image Recovery Algorithms for X-ray Interferometry (opens in a new tab)

  10. Non-Destructive Characterization of Zircaloy-4 Nuclear Fuel Cladding Using Neutron Scattering Techniques

    … C<sub>H</sub> in three dimensions (3D). Neutron grating interferometry (nGI) was used to identify microdefects within the H-rich regions of each sample. nCT and nGI measurements were collected at the CG-1D imaging beamline at the High Flux Isotope Reactor (HFIR). Neutron diffraction (nD), …

    utk-theses Repository record for Non-Destructive Characterization of Zircaloy-4 Nuclear Fuel Cladding Using Neutron Scattering Techniques (opens in a new tab)

  11. High Performance Reconstruction Framework for Straight Ray Tomography : from Micro to Nano Resolution Imaging

    … which we apply the methods of our framework are grating-based \mbox{x-ray} imaging (GI) and single-particle analysis (SPA). In the context of micro-resolution GI, three complementary characteristics are measured: the conventional absorption contrast, the differential phase contrast, and the …

    epfl Repository record for High Performance Reconstruction Framework for Straight Ray Tomography : from Micro to Nano Resolution Imaging (opens in a new tab)

  12. Synchrotron imaging of bovine and human ovaries ex vivo

    … study was conducted to explore the use of Talbot Grating Interferometry (TGI-CT) imaging of bovine (n=1) and human ovaries (n=1). Fresh and formalin-fixed bovine and human ovaries were imaged without or with contrast injection into the ovarian artery. Following synchrotron imaging, all ovarian …

    sask Repository record for Synchrotron imaging of bovine and human ovaries ex vivo (opens in a new tab)

  13. Imagerie de phase quantitative par interférométrie à décalage quadri-latéral. Application au domaine des rayons x durs

    Depuis la découverte des rayons X par Röntgen, l'imagerie radiographique utilise le contraste d'absorption. Cette technique est efficace uniquement si les objets à étudier sont suffisamment absorbants. C'est pour cela qu'on peut détecter une lésion osseuse avec une radiographie, mais pas une lésion …

    star-france Repository record for Imagerie de phase quantitative par interférométrie à décalage quadri-latéral. Application au domaine des rayons x durs (opens in a new tab)