Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Grey levels"”
-
Replication patterns for polygon fill algorithms
… for producing bilevel patterns to simulate grey level values for use in polygon regions as generated for computer graphics. Random distribution, ordered dither, and error diffusion methods are shown to be visually inferior for many grey levels to the proposed maxmin algorithm for producing …
-
Noise-limited performance of a hybrid detector and high-resolution display monitors.
… matrix of at least 1024 x 1536 pixels and 256 grey levels. The maximum luminance from the monitors was 88 ft-Lamberts (for the US Pixel monitor) and a maximum information capacity of 8.9 x 10⁶ bits (for the MegaScan monitor). We measured spatial and temporal noise for the monitors. Spatial …
-
Space and time efficient data structures in texture feature extraction
… is an important objective. The Spatial Grey Level Dependence Method (SGLDM) is one of the most important statistical texture analysis methods, especially in medical image processing. Co-occurrence matrices are employed for its implementation. However, they are inefficient in terms of …
-
Image processing
… thesis, we consider the restoration of multiple grey levels image. The problem is to clean up or restore the dirty picture, that is, to construct an estimate of the true image from a noisy picture of that true image. Following a method proposed by Meloche and Zamar (1994), we estimate the colour …
-
A fast motion estimation algorithm for mobile devices
… of 16x16 (256) pixels with each pixel having 256 grey levels. For each macroblock we compute the SAD by simply adding all grey levels of the 256 pixels. Next, the average and standard deviation of all macroblocks' SADs are calculated and all SADs are sorted in descending order. Based on thresholds …
-
Segmentation of brain x-ray CT images using seeded region growing
… of noise values, object sizes and mean object grey levels. All the methods were first implemented in two- and then three-dimensions. The 3-D implementation also included an investigation into volume formation and the advantages of 3-D processing. The results of the intracranial extraction …
-
Calibration of ultrasound scanners for surface impedance measurement
… be used, with interpolation, to relate measured grey level to impedance for the characterization of tissue specimens with unknown properties. This approach can be used independent of different medical ultrasound scanner systems to solve for reproducible tissue impedance values without offline …
-
Accuracy of fractal and multifractal measures for signal analysis
… to characterize complicated distributions of the grey levels in images. (Abstract shortened by UMI.)
-
Static and dynamic analysis of near infra-red dorsal hand vein images for biometric applications
… regions of interest extraction (ROI), grey level normalisation, noise reduction and image enhancement. Then, skin and vein areas from the dorsal hand were segmented using maximum curvature based algorithms. Due to varying haemoglobin and water levels in the vein and skin, intensity …
-
Advancing Label Free Imaging for Understanding Tissue Structure and Health
… texture feature extraction which relies on a grey level coocurrence matrix (GLCM) to enumerate all the pairs of pixels with specified grey levels. From here the 14 Haralick features are calculated by applying equations to the GLCM to quantity the distribution of grey levels. This method has …
-
Sonographie der Trächtigkeit beim Europäischen Reh (Capreolus capreolus) und Quantifizierung endometrialer Veränderungen während der Diapause mittels computergestützter Graustufenanalyse
… characterised by an increase in fluid associated grey levels. Long term ultrasound examinations revealed a continuous increase in endometrial fluid content over the last three month of eD, probably caused by a retention of secretory vesicles in cells of the uterine glands. During elongation of the …
-
The investigation and design of a machine vision system for the detection and control of the separation in a spinal ore concentrator
… was used to find the difference of averages of grey levels between two global neighborhoods within a specified area of interest window. The algorithm gave consistent results and was robust towards surface irregularities. The algorithm, operating in a continuous repetitive mode, gave rapid …
-
The vocal tract areagrah: a new technique for displaying speech
… as the vertical axis and spectral density as the grey level the areagram has distance along the vocal tract and cross-sectional areas respectively. The areagram is proposed as a complementary display to the spectrogram and not as a replacement. Features of the spectrogram such as formants and Ioci …
-
Standardization of texture analysis using IQ phantom under preclinical PET imaging
… του bin size (συνολικού αριθμού των εντάσεων των grey levels) στον υπολογισμό των χαρακτηριστικών υφής, καθώς και στην αναπαραγωγιμότητά, επαναληψιμότητά και αξιοπιστία τους (κάτω από συγκεκριμένες συνθήκες, τόσο όσον αφορά τα πρωτόκολλα ανακατασκευής της εικόνας όσο και τους χρόνους λήψης της …
-
Application of human visual perception paradigm for automated inspection of monochromatic security documents
… intensity normalization, which redistributes the grey levels in the test image to match a defined standard reflectance. (This technique does not change the feature distribution in the test image; the flaws are unchanged by normalization.) Spatial errors are caused by positional misalignment …
-
Ανάπτυξη νέων τεχνικών επεξεργασίας και εξαγωγής χαρακτηριστικών σε πολυτονικές εικόνες
… Boolean functions 3.composition of the processed levels to a new word value CLF have a wide range of applications in image processing. The main features of CLF are 1.simplicity 2.speed 3.inherent parallelism4.grate performanceThe above features make CLF very appropriate for H/W implementation. …
-
Signal estimation techniques using Lp-norm optimal stack filters with applications to image and video processing
… for stack filtering depend on the number of grey levels of an input image (signal). In this thesis, two new hardware-oriented algorithms for multidimensional stack filtering, for which the time-area complexity depends on the size of the filter, are developed. The new algorithms achieve …
-
Demixing phenomena in 2D bose gases
La démixtion est un phénomène facilement observé dans la vie de tous les jours, et se produit quand deux espèces, ayant l’une pour l’autre une force d’interaction suffisamment répulsive, sont réunies. Comme l’état mélange est instable, une instabilité hydrodynamique se développe, et tend à séparer …