Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 65 for “"Grid code"”.
-
Development of an Automated Framework for Testing Grid Code Compliance
… for Electricity (ENTSOE) has designed network codes to ensure the safe operation of the European power grids. Each individual transmission system operator (TSO) has then, based on the network codes from ENTSO-E, defined grid codes that all operators connected to the power system must comply …
-
Benchmarking power station voltage dip performance to meet the grid code requirements
… requirements of the South African National Grid Code form the background to the study. Typical power plant design and operating philosophy, the available technology and the literature examined in the study enriches this background. Included in the technology review and literature study are …
-
Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System
… countries have progressively revised their grid codes (GCs) to reduce the likelihood of protection malfunctions and ensure stable and continuous operation of power systems. Similar to emerging regional GCs, the recently approved IEEE 2800 Standard mandates that IBRs generate …
-
Wind power dynamic behaviour - Real case study on Linderödsåsen wind farm
… by regulation to stay online and support the grid during voltage dips, but for wind farms no such regulation have historically existed. In 2005, the Swedish transmission system operator (TSO) acknowledged the forthcoming need for regulation and issued a new grid code including connection …
-
Grid Codes Comparison
… coordination for different system operators. The grid codes are the technical specifications emitted principally by the Transmission System Operators (TSO). These sets of regulations do not follow a specific format since every country elaborates its own grid codes according to their requirements. …
-
Mitigation of operational risk in South African distribution networks with integrated renewable generation
… energy (RE) generation must comply with the RE grid code in South Africa. This ensures a predictable response of the RE facility under normal, weak and fault conditions. As the penetration level of RE generation increased, the requirements imposed on the RE generators also increased and become …
-
Swedish Transmission Grid Model Based on Open Sources
… it difficult to perform pre-studies on the grid. A grid model of the Swedish transmission system has been created in the simulation software PSS/E. The model is based entirely on open sources which was one of the main aims of the project. The constructed model in PSS/E consists of 221 buses, …
-
Multi-technology offshore wind power systems : control and dynamic performance assessment
… of wind turbines in order to improve the grid code compliance of the overall wind farm by exploiting the unique characteristics of both technologies to support each other in case of a fault happening. As a result, this thesis presents a novel control strategy for fully rated converter wind …
-
Fault Ride-through of Wind Parks with Induction Generators
… techniques to help the wind park meet grid code requirements, especially concerning fault ride-through. In this study, the wind turbine generators are selected to be fixed-speed induction generators without reactive power controllability. The studied wind park is made of one hundred and …
-
Συμβολή στην ανάπτυξη τεχνικών ελέγχου για συστήματα διασύνδεσης υψηλής τάσης, συνεχούς ρεύματος, τύπου πηγής τάσης (VSC-HVDC), θαλάσσιων αιολικών πάρκων και νησιών
… and control of multi-terminal HVDC (MTDC) grids, under steady-state and transient conditions.In the first part of the thesis, the dynamic models and the relevant controllers are presented for VSC-HVDC links, in order to evaluate their dynamic response as well as to validate the developed …
-
Power Grid Integration of GigaWatt-scale Hydrogen Production
… station is connected to the HVAC transmission grid through a step-down distribution system with two voltage levels, 400 and 33 kV. This grid is assumed to have a high short circuit capacity given the high demand of power and its design needs to comply with grid code requirements and …
-
Power System Grid Planning with Distributed Generation
… flow creates complexity in the power system grid planning due to the conversion of the power system from a passive network to an active network. Introduction of bi-directional power flow on the power system can, among other benefits reduce local power demand which opens opportunities for …
-
Thermodynamic behaviour of supercritical water as working fluid in advanced coal-fired power plants: simulation and design study
… clean coal technology; however the UK National Grid Code is built around conventional power plants, and thus compliance is uncertain. Modelling the thermal behaviour of the supercritical boiler water cycle using computational fluid dynamics is a practical method to approach compliance. The CFD …
-
Modeling of Inverter-Based Resources for Hardware in the Loop Testing of Protection and Control Schemes
… control schemes, and implementing modern grid codes for seamless IBR integration during fault ride-through (FRT) events. Additionally, the study examines the performance of transmission line distance protective relays when interfacing with IBRs and explores IBR fault ride-through …
-
Probabilistic short circuit calculation and its application in voltage sag estimation considering fault ride through of distributed generator
… on a typical Dutch Medium Voltage distribution grid where the penetration level of Distributed Generation (DG) is experiencing rapid growth. Fault Ride Through (FRT) capability will be obligatory for Voltage Source Converter (VSC) based DG in future grid code which is different with currently …
-
A discriminative approach to harmonic emission assessment
… assessment of a Renewable Power Plant (RPP) for grid code compliance, is a complex task that requires a fair and pragmatic approach. RPPs should only account for the harmonics they emit, i.e. those which negatively affect the harmonic voltage at the Point of Connection (PoC). Most of the harmonic …
Page 1 of 4