Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 31 for “"Grouted masonry"”
-
Shear Strength Prediction Methods for Grouted Masonry Shear Walls
… predicting the shear strength of reinforcement masonry shear walls. Each approach provides increasing accuracy and precision in predicting the shear strength of masonry walls. The three approaches were developed or validated using data from 353 wall tests that have been conducted over the past …
-
Statistical Prediction Methods for the In-Plane Shear Strength of Partially Grouted Masonry Walls
The behaviour of partially grouted masonry shear walls is complex due to their anisotropic nature and the nonlinear interactions between blocks, mortar, grouted cells, ungrouted cells and steel reinforcement. Currently available code- and research-based shear strength equations give highly variable …
-
Artificial Neural Network Model for Analysis of In-Plane Shear Strength of Partially Grouted Masonry Shear Walls
The behaviour of partially grouted (PG) masonry shear walls is complex, due to the inherent anisotropic properties of masonry materials and nonlinear interactions between the mortar, blocks, grouted cells, ungrouted cells, and reinforcing steel. Since PG shear walls are often part of lateral force …
-
Flexural Bond Strength of Masonry Assemblies with Lightweight Grout
Lightweight grout has many potential benefits in masonry construction, including minimizing mass, improving thermal performance, and potentially reducing shrinkage cracking via internal curing. However, insufficient testing of masonry assemblies with lightweight grout has been conducted to suggest …
-
Towards a Rational Analysis and Design of Partially-Grouted Concrete Block Masonry Walls Under In-Plane Shear
Masonry wall systems are an essential structural component of a building, providing resistance against lateral and gravity loads. Due to its economy and efficiency, most masonry walls in low- to moderate-seismic markets are partially-grouted, in which only the reinforced cells are filled with …
-
Failure mechanisms of concrete masonry
The behaviour of concrete masonry under in-plane compression combined with out-of-plane bending was examined both experimentally and analytically. Ungrouted and grouted masonry, both fully bedded or face-shell bedded, were included in the study. It was found that the masonry under the above stated …
-
Parametric Study on Multi-Story, Partially Grouted, Perforated, Masonry Shear Walls by Finite Element Analysis
… their influence on multi-story, partially grouted, perforated (openings), masonry shear walls using a finite element software FormWorks. The parameters studied were: the strength of grouted masonry prisms f'm,grouted; the strength of un-grouted (hollow) masonry prisms f'm,ungrouted; the …
-
Strut-and-Tie Modeling of Multistory, Partially-Grouted, Concrete Masonry Shear Walls with Openings
… but may also come at a cost of strength. In masonry shear walls, it is becoming more common to reduce the amount of grouting from every cell to only those with reinforcement, a practice known as partial-grouting. Partially-grouted masonry responds differently and in a more complex matter to …
-
Caracterização da alvenaria estrutural de alta resistência
… parts. The first part reports the structural masonry properties characterization, with focus on determine the influence of the grout compressive strength to the compressive strength of grouted masonry constructed with high strength concrete masonry units, and the study of a new material used …
-
Analytical and Experimental Studies to Support Codification of Lightweight Grout for Masonry Design
… (LW) aggregates have many potential benefits in masonry construction including minimizing mass, improving thermal performance, and reducing the potential for shrinkage cracking via internal curing. The current masonry design standard, TMS 402/602-22, permits lightweight aggregate in the …
-
Compressive Stress-strain of Unreinforced Masonry Boundary Element Prisms
Reinforced masonry shear walls (RMSW) with masonry boundary elements (BE) are rectangular walls having integrated masonry BEs at the wall extremities. These BEs can be constructed using half pilaster block (i.e. C-shaped blocks) or regular stretchers. The compressive stress-strain response of the …
-
Modelling In-plane Shear in Partially Reinforced Concrete Masonry
… the most commonly reported mode of failure for masonry walls subject to in-plane shear loads. Finite element studies were therefore carried out to seek better understanding of this failure mode by attempting to capture the diagonal shear cracks in unreinforced concrete masonry and partially …
-
Seismic performance, analysis, and design of hybrid concrete-masonry
Caribbean-style hybrid concrete-masonry structures consist of a reinforced concrete frame with partially grouted and reinforced infill masonry walls. The infill walls are typically connected to the RC frame with cast-in-place dowel reinforcement along one or more edges of the wall. There is limited …
-
Paredes de contraventamento de alvenaria grauteadas e armadas nas extremidades: comportamento, capacidade, desempenho sísmico e modelos simplificados de projeto
Partially grouted masonry structures are widely used worldwide, preferably in regions with low and mid-intensity wind and seismic loads. Thus, this thesis focuses on partially grouted masonry walls (PGMW), especially those with grout and reinforcement placed at their ends. The objectives were to …
-
Performance of No Vibration/No Admixture Masonry Grout Containing High Replacement of Portland Cement with Fly Ash and Ground Granulated Blast Furnace Slag
When hollow concrete masonry is used for construction in high seismic regions, structural designs typically require fully grouted walls. The grouting process is labor-intensive, time-consuming and has a high energy demand due to requirements of consolidation in each and subsequent grout lifts. …
-
Non-Destructive Means of Predicting Masonry Prism Strength Using Ultrasonic Pulse Velocity (UPV)
Current ASTM standards call for grouted masonry prisms to be tested for compressive strength at 28-days to ensure compliance with the structural design. In the event of failing tests, the subject samples may require redesign or reconstruction which can pose problems due to ongoing development …
-
Flat Arch Masonry Retaining Wall
The inherent strength and durability of masonry arches is eminent through many historical structures still existing to this day. Amidst a wide range of retaining wall types and applications available, the concept of utilizing masonry arches as earth retaining structures is surprisingly …
-
Investigation on the Shear Strength and Capacity of Concrete Block Masonry
Partially grouted concrete masonry shear walls are widely used because they provide a balance between structural performance and construction efficiency. However, the effects of material properties, grouting, and reinforcement on their shear resistance are not fully understood, and existing design …
-
Short and Long Term Capacities of Slender Concrete Block Walls
… long term capacities of slender concrete block masonry walls subject to eccentric axial loads were investigated. A finite element model was developed to include both the geometric and the material nonlinearities. To analyze large members, a combined macro-micro finite element model for the …
-
Enhanced Ductility of Masonry Shear Walls Using Laterally Confined (Self-Reinforced) Concrete Block
… a new method of improving the ductility of masonry shear walls by means of confinement. This proprietary method, referred to as Self-Reinforced Concrete Block (SR Block) employs a previously untried technique of molding lateral confining devices into concrete block. This internal …
Page 1 of 2