Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 49 for “"HDR Brachytherapy"”

  1. HDR Brachytherapy for Skin Cancer Using H.A.M. Applicator

    … optimizing superficial cosmesis. High dose rate (HDR) brachytherapy provides an alternative to superficial x-ray or electron beam for skin cancer treatment. Utilizing an Iridium 192 source soldered to the end of a wire, surface dose can be administered at predetermined positions with sharper dose …

    unlv Repository record for HDR Brachytherapy for Skin Cancer Using H.A.M. Applicator (opens in a new tab)

  2. Error Analysis of non-TLD HDR Brachytherapy Dosimetric Techniques

    … the experimental absolute dose rate for brachytherapy. The recommended uncertainty estimates associated with TLD experimental dosimetry include 5% for statistical errors (Type A) and 7% for systematic errors (Type B). TG-43U1 protocol does not include recommendation for other experimental …

    ohiolink Repository record for Error Analysis of non-TLD HDR Brachytherapy Dosimetric Techniques (opens in a new tab)

  3. Dose intercomparisons between computer planning, in-vivo and phantom measurements for Iridium-192 HDR Brachytherapy

    During gynaecological high-dose rate (HDR) intracavitary brachytherapy (ICBT), invivo dosimetry is done to monitor the dose received by the bladder and rectum. This study was aimed at validating the need to do in-vivo dosimetry during ICBT. Thirty patients were recruited to participate in the …

    cape-town Repository record for Dose intercomparisons between computer planning, in-vivo and phantom measurements for Iridium-192 HDR Brachytherapy (opens in a new tab)

  4. Design of a minimally invasive single port HDR brachytherapy applicator for the treatment of lung cancer

    … many cases a less aggressive alternative such as brachytherapy may be preferable. Today, HDR brachytherapy is a relatively common procedure but with current techniques and equipment only tumours close to the main bronchi can be reached. This project describes the design, development and validation …

    uwo Repository record for Design of a minimally invasive single port HDR brachytherapy applicator for the treatment of lung cancer (opens in a new tab)

  5. In Vivo Dosimetry in HDR Brachytherapy - pre-clinical tests of the prototype system PRO-DOSE (NU-RISE)

    High-dose-rate (HDR) brachytherapy involves multiple procedural steps that may result in discrepancies between the prescribed dose and the actual dose delivered to the patient. To identify these discrepancies during treatment, a process known as in vivo dosimetry (IVD), it is necessary to utilize …

    coimbro Repository record for In Vivo Dosimetry in HDR Brachytherapy - pre-clinical tests of the prototype system PRO-DOSE (NU-RISE) (opens in a new tab)

  6. A probabilistic framework for prostate core-needle biopsies in HDR brachytherapy : from clinical quality assurance to translational research

    … biopsies acquired during high-dose-rate (HDR) brachytherapy are clinically useful for diagnosis and can also support translational research when linked to sampled tissue, imaging-defined anatomy, and delivered dose. The main obstacle is that the effective biopsy location is uncertain by …

    ubc Repository record for A probabilistic framework for prostate core-needle biopsies in HDR brachytherapy : from clinical quality assurance to translational research (opens in a new tab)

  7. Inter-fraction Variability of High-Risk Clinical Target Volume (HR-CTV) and Organs at Risk (OARs) in Cervical Cancer High-Dose-Rate (HDR) Brachytherapy

    High-dose-rate (HDR) tandem and ring cervical brachytherapy requires significant time and resources from implant, to imaging, planning, and treatment. The high-risk clinical target volume (HR-CTV) and organs at risk (OARs) are contoured on MRI. To save time and resources without compromising target …

    umn Repository record for Inter-fraction Variability of High-Risk Clinical Target Volume (HR-CTV) and Organs at Risk (OARs) in Cervical Cancer High-Dose-Rate (HDR) Brachytherapy (opens in a new tab)

  8. A Three-Dimensional Ultrasound-Based Workflow for Gynecologic Brachytherapy: Development and Validation of Imaging Systems and Methods

    High dose rate (HDR) brachytherapy is a form of radiation therapy used in the treatment of gynecologic cancers that provides conformal dose to the cancerous tissue while sparing nearby healthy organs. Treatment success depends on accurate brachytherapy applicator placement and medical imaging to …

    uwo Repository record for A Three-Dimensional Ultrasound-Based Workflow for Gynecologic Brachytherapy: Development and Validation of Imaging Systems and Methods (opens in a new tab)

  9. The importance of immobilization and localization of gynecological applicators in high dose rate brachytherapy treatments

    Intracavitary high dose rate (HDR) brachytherapy is a form of radiation therapy generally in which a post-surgical tissue margin is treated. The dose gradient of HDR brachytherapy is very steep, and thus small displacements of the applicator, even as small as 1 mm, could potentially cause …

    fau Repository record for The importance of immobilization and localization of gynecological applicators in high dose rate brachytherapy treatments (opens in a new tab)

  10. 2D brachytherapy planning versus 3D brachytherapy planning for patients with cervical cancer

    … Aims The purpose of this study is to compare 2D HDR Brachytherapy planning and 3D HDR Brachytherapy planning in terms of dose distribution in order to accurately determine bladder and rectal doses. Further research questions were explored to determine whether relationships existed between …

    dut Repository record for 2D brachytherapy planning versus 3D brachytherapy planning for patients with cervical cancer (opens in a new tab)

  11. Ανάπτυξη αλγορίθμων και μεθόδων ποιοτικού ελέγχου για το δοσιμετρικό σχεδιασμό εφαρμογών βραχυθεραπείας

    … Systems (TPSs) for 192Ir High-Dose-Rate (HDR) brachytherapy. The complexity of these algorithms, however, introduces new quality assurance (QA) standards augmentιng current societal recommendations, while an effort is needed towards evaluating the clinical impact of the improved dosimetric …

    greece Repository record for Ανάπτυξη αλγορίθμων και μεθόδων ποιοτικού ελέγχου για το δοσιμετρικό σχεδιασμό εφαρμογών βραχυθεραπείας (opens in a new tab)

  12. Production and evaluation of novel brachytherapy sources

    … 169Yb and 153Gd are attractive candidates as brachytherapy radiation sources. The first aim of this work was to evaluate the potential of these novel sources, in terms of radiobiological advantages, for applications in high dose rate (HDR) brachytherapy. The radiation quality of these …

    mcgill Repository record for Production and evaluation of novel brachytherapy sources (opens in a new tab)

  13. Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout

    … specific quality assurance. High dose rate (HDR) brachytherapy treatments have become more complex, but patient specific QA has not been adopted. One reason for this is the lack of inexpensive, simple to use, accurate, and complete dosimeters for brachytherapy. Radiochromic gel dosimeters …

    queens Repository record for Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout (opens in a new tab)

  14. Dosimetric comparison of inverse planning by simulated annealing (IPSA) and dosepoints optimized treatment plans in high dose rate (HDR) brachytherapy of skin lesions using Freiburg flap applicator

    … plans has been performed for High Dose Rate (HDR) brachytherapy of skin lesions using Freiburg Flap applicator in order to find out whether or not IPSA offers better clinical dosimetric outcomes for lesions categorized into four different curvatures. Without compromising target coverage, IPSA …

    fau Repository record for Dosimetric comparison of inverse planning by simulated annealing (IPSA) and dosepoints optimized treatment plans in high dose rate (HDR) brachytherapy of skin lesions using Freiburg flap applicator (opens in a new tab)

  15. Determinación de la distribución de dosis en tratamientos de cáncer de mama con fuentes de 192 Ir HDR

    La Braquiterapia de alta tasa de dosis HDR es una moderna técnica de tratamiento que ha venido teniendo un rápido crecimiento en su uso clínico, reemplazando a la braquiterapia de baja tasa de dosis LDR. La braquiterapia HDR se caracteriza por utilizar fuentes radiactivas con tasas de dosis mayores …

    un-colombia Repository record for Determinación de la distribución de dosis en tratamientos de cáncer de mama con fuentes de 192 Ir HDR (opens in a new tab)

  16. Brachytherapy dosimetry with fricke-gelatin and MRI

    … absorbed dose distributions from high dose rate (HDR) brachytherapy treatments. The high activity of the HDR brachytherapy source is suitable for the prompt delivery of the high doses required to give changes in the Fricke-gelatin Nuclear Magnetic Resonance (NMR) characteristics which are readily …

    mcgill Repository record for Brachytherapy dosimetry with fricke-gelatin and MRI (opens in a new tab)

  17. Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry

    … phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm3 prototype with two slots capable of holding nanoDot Al2O3:C OSL dosimeters (Landauer, Glenwood, IL) was designed and built. The …

    uthsc Repository record for Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry (opens in a new tab)

  18. New Optimization Technique for Radiation Therapy Planning

    … to Gamma Knife radiosurgery and High-Dose Rate Brachytherapy (HDR) for prostate cancer. Mathematically, Gamma Knife radiosurgery is a ball-packing process whose goal is to 'pack' some spherical high dose volumes into a tumor volume, while brachytherapy is to find the trajectories of some …

    unm Repository record for New Optimization Technique for Radiation Therapy Planning (opens in a new tab)

  19. The introduction of brachytherapy to the country of Botswana

    … external beam radiation therapy and brachytherapy. The goal of this present study is to describe the challenges and implementation of brachytherapy in the country of Botswana in 2012 and to report its uses within the cervical cancer population between 2012 and 2014. The government of …

    bu Repository record for The introduction of brachytherapy to the country of Botswana (opens in a new tab)

  20. Prostate high dose-rate brachytherapy in men with bilateral hip prostheses.

    … useful treatment planning images for prostate HDR brachytherapy. Prostheses can introduce severe artifact into the principal modalities used for HDR prostate brachytherapy imaging – ultrasound, magnetic resonance imaging (MR) and computed tomography (CT). This study aimed to develop a protocol …

    adelaide Repository record for Prostate high dose-rate brachytherapy in men with bilateral hip prostheses. (opens in a new tab)

Page 1 of 3