Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"HEPA filter"”.

  1. Investigate Woodsmoke and Interventions in an Exposure Chamber: A Tent Project

    … smoke PM intervention strategies, especially HEPA (high-efficiency particulate air)-filter portable air cleaners (PACs) and HEPA-installed powered air-purifying respirators (PAPRs), for their particle removal efficiency and effectiveness in a laboratory setting. Objectives: This research was …

    washington Repository record for Investigate Woodsmoke and Interventions in an Exposure Chamber: A Tent Project (opens in a new tab)

  2. Infiltration of forest fire and residential wood smoke : an intervention study to asssess [sic] air cleaner effectiveness

    … of High Efficiency Particulate Air (HEPA) filter air cleaners in reducing indoor PM2.5 and to investigate determinants of infiltration and air cleaner effectiveness in homes. Winter sampling at 21 homes was conducted in 2004 in a northern Canadian community affected by residential …

    ubc Repository record for Infiltration of forest fire and residential wood smoke : an intervention study to asssess [sic] air cleaner effectiveness (opens in a new tab) Download PDF for Infiltration of forest fire and residential wood smoke : an intervention study to asssess [sic] air cleaner effectiveness (opens in a new tab)

  3. A Microbiological Evaluation of a Laminar Down-Flow Hood

    … DF-400 laminar down flow hood with an exhaust HEPA filter adaptation was tested for its efficiency by using Bacillus subtilis var. niger as an indicator organism. The experimental emphasis was on the bacterial spore penetration of the frontal barrier and of the exhaust system. Interior and …

    unm Repository record for A Microbiological Evaluation of a Laminar Down-Flow Hood (opens in a new tab)

  4. Humidity effects on hygroscopic particles deposited on HEPA filters and silicon wafer surfaces

    … fab air is cleaned bypassing it through either HEPA or ULPA filters. A number of airborne fab contaminants may be hygroscopic causing them to exist as a solid or a liquid when in equilibrium with their environment's relative humidity. The effect of relative humidity on such contaminants is …

    texas Repository record for Humidity effects on hygroscopic particles deposited on HEPA filters and silicon wafer surfaces (opens in a new tab)

  5. Allergen-Rückhaltevermögen von Luftfiltergeräten mit HEPA-Filtern und Tierallergenexposition im Verlauf in Haushalten tierallergischer Kinder und Jugendlicher mit Asthma bronchiale

    … im Kindesalter. Über die Rolle von Luftfiltergeräten, die durch Reduktion von Tierallergenen zur Prävention und Therapie von tierallergischem Asthma bronchiale beitragen sollen, gibt es bisher unterschiedliche Daten. In dieser Studie wurden daher 33 asthmakranke Kinder (Alter 6-17Jahre) …

    fu-berlin Repository record for Allergen-Rückhaltevermögen von Luftfiltergeräten mit HEPA-Filtern und Tierallergenexposition im Verlauf in Haushalten tierallergischer Kinder und Jugendlicher mit Asthma bronchiale (opens in a new tab)

  6. Uppbyggnad av luftbehandlingssystem för operationsrum. Dokumentation och mätningar

    … värmeväxlaren eftersom all luft filtreras genom HEPA-filter innan den tillförs operationssalarna. Blandningsförhållandet mellan recirkulationsluft och luft från det allmänna systemet anpassas efter inblåsningstemperaturen och internlasterna i operationsrummet. När blandningsförhållandet är …

    chalmers Repository record for Uppbyggnad av luftbehandlingssystem för operationsrum. Dokumentation och mätningar (opens in a new tab)

  7. Modeling contaminant spread and mitigation in the indoor environment

    … device is investigated together with other filters. The protection factor (PF, a ratio of concentration integrated over time in the ambient to that indoors) is chosen as a performance metric. A PF-oriented evaluation framework has been established such that ventilation system/strategy (or …

    uiuc Repository record for Modeling contaminant spread and mitigation in the indoor environment (opens in a new tab)

  8. Using Sensors to Investigate the Effectiveness of Portable Air Filtration for Reducing Particle Exposures: Implications for Community Congregate Settings

    … the real-world effectiveness of portable HEPA air cleaners (HEPA PACs) in reducing indoor particle levels in community congregate settings, while assessing usage patterns and factors influencing their efficacy, and 3) Understand the impact of filter dust loading on HEPA PAC’s long-term …

    washington Repository record for Using Sensors to Investigate the Effectiveness of Portable Air Filtration for Reducing Particle Exposures: Implications for Community Congregate Settings (opens in a new tab)

  9. Fission product transport during pipebreaks in a PBMR confinement

    … vented through high efficiency particulate air (HEPA) filters into the environment. In support of the design and safety analysis of the plant, pipe break scenarios are analysed to provide insight on the expected consequences of such an event. This study focused on quantifying the retention …

    nwu-za Repository record for Fission product transport during pipebreaks in a PBMR confinement (opens in a new tab)

  10. Numerical modelling of aerosol and CO2 transport for indoor air quality and infection risk assessment

    … of exhaled CO2 and aerosols under stale air, HEPA-filtered, and mechanically ventilated conditions. It also introduces a novel infection risk model that utilises aerosol measurements for real-time risk estimation and generates spatiotemporal maps of infection risk and safe occupancy time based …

    unsw Repository record for Numerical modelling of aerosol and CO2 transport for indoor air quality and infection risk assessment (opens in a new tab)

  11. Laboratory and Real-World Measurement of Diesel Particulate Matter

    … the tunnel flow and wall temperature, the PM filter face temperature, and the system's estimated theoretical PM diffusion losses. A computational fluid dynamic (CFD) model was also set up to help the selection of the location and sizes of the mixing orifice plates, as well as the …

    wvu Repository record for Laboratory and Real-World Measurement of Diesel Particulate Matter (opens in a new tab)

  12. Návrh větrání laboratoře pro přípravu cytostatik

    Cílem této diplomové práce je seznámit a provést čitatele všemi důležitými aspekty návrhu vzduchotechnického systému pro cytostatickou laboratoř, počínaje teoritickými poznatky o dané problematice, přes obeznámení s příslušnými legislativními předpisy, ukázku relevantních výpočtů potřebných pro …

    brno-tech Repository record for Návrh větrání laboratoře pro přípravu cytostatik (opens in a new tab)

  13. The Effects of Ozone Exposure on Cardiovascular Pathophysiology

    … of a high efficiency particulate air (HEPA) filter and a particle-removing and O3-producing electrostatic precipitator (ESP). Eighty-nine healthy participants living on a work campus in Changsha City, China were recruited for this study conducted from December 1st, 2014 - January 31st, …

    duke Repository record for The Effects of Ozone Exposure on Cardiovascular Pathophysiology (opens in a new tab)

  14. Vzduchotechnika hokejové haly

    Bakalářská práce se zabývá návrhem vzduchotechnického systému pro hokejovou halu. V objektu, který je rozdělen na tři části se řeší hokejová hala „A“, hokejová hala „B“ a zázemí haly. Vzduchotechnika zajišťuje nucené větrání a upravuje vzduch, který je přiváděn. Zařízení jsou navržena, aby …

    brno-tech Repository record for Vzduchotechnika hokejové haly (opens in a new tab)

  15. Vzduchotechnika operačních sálů

    Cílem této bakalářské práce je návrh vzduchotechnických systémů na operačních sálech a prostorách, které jsou nezbytně nutné k zajištění provozu těchto sálů. Navržené zařízení splňuje příslušné normy a hy-gienické, provozní požadavky. Výpočtová část je zpracovaná na úrovni prováděcího projektu. …

    brno-tech Repository record for Vzduchotechnika operačních sálů (opens in a new tab)

  16. Vzduchotechnika dvojice operačních sálů a jejich zázemí

    Tématem této bakalářské práce je návrh vzduchotechnického systému zajišťujícího výměnu a úpravu vzduchu dvojice operačních sálů a jejich zázemí. Zařízení splňují hygienické, provozní a funkční požadavky na vnitřní mikroklima. Výpočtová část je zpracována na úrovni prováděcího projektu. Teoretická …

    brno-tech Repository record for Vzduchotechnika dvojice operačních sálů a jejich zázemí (opens in a new tab)

  17. Vzduchotechnika jednotky intenzivní péče

    Cílem této bakalářské práce je návrh vzduchotechnických a klimatizačních systémů v prostorách JIP infekčního oddělení a zázemí zaměstnanců nemocnice. Návrh zařízení splňuje příslušné normy, hygienické a provozní požadavky. Výpočtová část se zabývá celkovou analýzou objektu, tepelnými bilancemi, …

    brno-tech Repository record for Vzduchotechnika jednotky intenzivní péče (opens in a new tab)

  18. Aerosolové a mikrobiální mikroklima čistých prostorů

    Diplomová práce se zabývá problematikou vnitřního mikroklima čistých prostorů. Experimentální část se zaměřuje na aerosolové a mikrobiální mikroklima. Na různých operačních a zákrokových sálech byla provedena měření a z nich pak bylo vyhodnoceno, zda by daný čistý prostor vyhověl normové třídě …

    brno-tech Repository record for Aerosolové a mikrobiální mikroklima čistých prostorů (opens in a new tab)

  19. Návrh větrání čistého pracoviště pro elektrotechnický průmysl

    Diplomová práce zpracovává návrh klimatizace čistého pracoviště pro výrobu polovodičových součástek v elektrotechnickém průmyslu. Pro toto pracoviště jsou zadáním specifikovány vysoké nároky na čistotu vzduchu, toleranci pracovní teploty a relativní vlhkost. Diplomová práce v první části shrnuje …

    brno-tech Repository record for Návrh větrání čistého pracoviště pro elektrotechnický průmysl (opens in a new tab)