Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"HFE-7000"”.
-
A multi-functional electrolyte for lithium-ion batteries
… positive electrode of the cell. The inert fluid HFE-7000 is investigated as the volatile co-solvent in the MFE (1 M LiTFSI in 1:1 HFE-7000/ethyl methyl carbonate by volume) for the proposed TMS. In the first phase of the study, the baseline electrochemical performance of the MFE is determined by …
-
Development of nano composite coatings for enhanced performance in non-conventional lubricants under sliding contact.
… various operating conditions. Hydrofluoroethers (HFEs) are within the family of newly developed environmentally friendly refrigerants with a wide range of application areas. HFE-7000 is a replacement solution for the existing harmful refrigerants and thermo-fluids having a broad range of …
-
Experimental investigation and mathematical modelling of dynamic equilibrium of novel thermo-fluids for renewable technology applications
… and tested experimentally. In the experiments, HFE 7000 refrigerant that has zero ozone depletion potential (ODP) and low global warming potential (GWP) was employed. The performance of the system was evaluated in terms of energy and exergy analyses. In the 2nd stage, the flat plate collector …
-
Experimental Observation and Measurements of Pool Boiling Heat Transfer using PIV, Shadowgraphy, RICM Techniques
… data on a pool boiling experiments using HFE-7000. Particle Image Velocimetry (PIV) was used to measure the time resolved whole field liquid velocity. Bubble dynamic parameters such as nucleation site density, bubble departure diameter, contact angles and frequency were obtained in …
-
Experimental testing of convective spray cooling with the aid of an electrical field using the Coulomb force
… testing using working fluids, FC-72 and HFE-7000, was conducted. Electrodes were designed to inductively charge spray droplets (Law, 1978). Research was performed by studying the thermophysics for different spray flow rates ranging from 6 to 10 GPH with a stepwise applied heat load …
-
Investigation of Immersion Cooled ARM-Based Computer Clusters for Low-Cost, High-Performance Computing
… mode utilized two types of dielectric liquids, HFE-7000 and HFE-7100. Experiments involved running benchmarking tests Sysbench high performance linpack (HPL), and the combination of both in order to quantify the key parameters of device junction temperature, frequency, execution time, computing …
-
Effects of the electric Kelvin force on spray cooling performance
… code CFD ACE+ and the use of a different fluid, HFE-7000, showed a cooling effect of the heated surface as well as an increase of approximately 5% in the convection heat transfer coefficient.
-
STABLE ENERGY-EFFICIENT MACRO-SCALE PARTIAL FLOW-BOILING OPERATIONS USING MICROSTRUCTURED SURFACES AND ULTRASONICS
… micro-bubbles during flow-boiling of 3M Novec HFE 7000 is enabled by the use of inexpensive layers of woven copper mesh to form a microstructured boiling surface/region. These microstructured boiling regions are subjected to nano/micro-scale amplitude ultrasonic (~1 - 6 MHz) and sonic (< 2 kHz, …