Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 160 for “"HPGe"”.

  1. Βαθμονόμηση φορητού ανιχνευτή HPGe για in situ μετρήσεις

    … πραγματοποιήθηκε η βαθμονόμηση ενός ανιχνευτή HPGe ο οποίος ανήκει στην Ελληνική Επιτροπή Ατομικής Ενέργειας ( ΕΕΑΕ ), ώστε να γίνει δυνατή η χρήση του σε in situ μέτρηση στο πεδίο. Στο δεύτερο κεφάλαιο της ΔΕ, αναπτύσσεται θεωρητικά η έννοια της in situ φασματοσκοπίας, του τρόπου εφαρμογής της …

    athens Repository record for Βαθμονόμηση φορητού ανιχνευτή HPGe για in situ μετρήσεις (opens in a new tab)

  2. Spatially-resolved HPGe Gamma-ray Spectroscopy for Nuclear Forensics

    … Imager (GeGI) is a planar high purity germanium (HPGe) imaging detector developed by PHDS Co for far-field imaging. This research investigates the GeGI’s ability to measure heterogeneous sources in the near field, placed directly on the detector’s faceplate, to perform isotopic mapping useful to …

    tamu Repository record for Spatially-resolved HPGe Gamma-ray Spectroscopy for Nuclear Forensics (opens in a new tab)

  3. Characterization of Mechanically Cooled High Purity Germanium (HPGe) Detectors at Elevated Temperatures

    … the use of hand-held high purity germanium (HPGe) in homeland security applications have centered on weight, geometry, and cool-down time. Typical liquid nitrogen cooled detectors ranging in size from 10% to 150% detectors will cool down sufficiently within 2-6 hours of filling. The cool-down …

    utk-theses Repository record for Characterization of Mechanically Cooled High Purity Germanium (HPGe) Detectors at Elevated Temperatures (opens in a new tab)

  4. Efficiency optimization of a HPGe clover array for implantation decay experiments at FRIB

    … gamma ray detector array with a small, planar HPGe detector to study some of the most exotic nuclei. This project focused on ensuring that this combination would maintain or improve the photon efficiency of a clover style array on its own, as well as optimizing the size of the planar HPGe …

    colo-mines Repository record for Efficiency optimization of a HPGe clover array for implantation decay experiments at FRIB (opens in a new tab)

  5. Caracterización computacional de detextores de Germanio Hiperpuro (HPGe) empleando simulación Montecarlo y optimización mediante algoritmos evolutivos

    … de detectores de Germanio Hiperpuro (HPGe), reproducible en un laboratorio de investigación estándar. Dicha metodología consiste en optimizar modelos computacionales de dicho tipo de detectores, implementados en un código de simulación Montecarlo llamado PENELOPE, empleando para la …

    ulpgc Repository record for Caracterización computacional de detextores de Germanio Hiperpuro (HPGe) empleando simulación Montecarlo y optimización mediante algoritmos evolutivos (opens in a new tab)

  6. Search for 2nbb Excited State Transitions and HPGe Characterization for Surface Events in GERDA Phase II

    The search for the neutrinoless double beta (0nbb) decay is one of the most active fields in modern particle physics. This process is not allowed within the Standard Model and its observation would imply lepton number violation and would lead to the Majorana nature of neutrinos. The experimentally …

    qucosa-diss

  7. Process optimization and purity enhancement of germanium to grow HPGe single crystals towards high-sensitive radiation detectors

    High-purity germanium (HPGe) is one of the most efficient materials for radiation detectors used in rare-event physics experiments such as LEGEND, where high-quality single crystals with ultra-high purity (13N) and excellent charge transport properties are essential. This thesis investigates and …

    lmu-germany Repository record for Process optimization and purity enhancement of germanium to grow HPGe single crystals towards high-sensitive radiation detectors (opens in a new tab)

  8. Surface Alpha Interactions in P-Type Point-Contact HPGe Detectors: Maximizing Sensitivity of 76Ge Neutrinoless Double-Beta Decay Searches

    … point-contact (P-PC) high-purity Germanium (HPGe) detectors enriched in 76Ge, operated in large low-background arrays. This approach is used, with some key differences, by the MAJORANA and GERDA Collaborations. A problematic background in such large granular detector arrays is posed by alpha …

    washington Repository record for Surface Alpha Interactions in P-Type Point-Contact HPGe Detectors: Maximizing Sensitivity of 76Ge Neutrinoless Double-Beta Decay Searches (opens in a new tab)

  9. The prediction equations of the male and female chest wall thickness for measuring actinides within the lungs using HPGe detectors

    … three- or six-detector hyperpure germanium (HPGe) array, for measuring actinides within the lungs. Presently, there is not a gender-specific CWT prediction equation derived for HPGe detection systems. The majority of the U.S. Department of Energy lung counting facilities are using HPGe …

    ut-knoxville Repository record for The prediction equations of the male and female chest wall thickness for measuring actinides within the lungs using HPGe detectors (opens in a new tab)

  10. Gryno germanio gama detektoriaus efektyvumo kalibravimas taškinio ir tūrinio šaltinio atvejais naudojantis GEANT4 programa /

    … the GEANT4 program in order to create virtual HPGe detector and compare measured detector efficiency with standard detector efficiency. This paper discusses semiconductor detectors and their working principles. It also discusses gamma radiation interaction with matter. Furthermore, there is …

    vilnius Repository record for Gryno germanio gama detektoriaus efektyvumo kalibravimas taškinio ir tūrinio šaltinio atvejais naudojantis GEANT4 programa / (opens in a new tab)

  11. MODELING AND VALIDATION OF NEUTRON ACTIVATION AND GAMMA-RAY SPECTROSCOPY MEASUREMENTS AS AN EXPLORATORY TOOL FOR NUCLEAR FORENSIC ANALYSIS

    … spectroscopy with high-purity germanium (HPGe) detectors is the leading passive assay technique for radioactive samples, providing detailed qualitative and quantitative information while preserving sample integrity. A simple HPGe detector is modeled using MCNP to assess the measurability …

    maryland Repository record for MODELING AND VALIDATION OF NEUTRON ACTIVATION AND GAMMA-RAY SPECTROSCOPY MEASUREMENTS AS AN EXPLORATORY TOOL FOR NUCLEAR FORENSIC ANALYSIS (opens in a new tab)

  12. CHARACTERIZATION OF PARTIAL CHARGE COLLECTION INDUCED BY NEUTRON DAMAGE IN HIGH-PURITY GERMANIUM DETECTORS

    … interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the …

    unm Repository record for CHARACTERIZATION OF PARTIAL CHARGE COLLECTION INDUCED BY NEUTRON DAMAGE IN HIGH-PURITY GERMANIUM DETECTORS (opens in a new tab)

  13. Characterization of wound monitoring systems used to quantify and locate plutonium contamination

    … iodide (NaI(Tl)) and high purity germanium (HPGe) detection systems. The NaI(Tl) system is used to quantify the amount of contamination, while HPGe is used to gauge the depth of contamination in the wound. Assessment of plutonium contaminated wounds is difficult due to the lowenergy and yield …

    tamu Repository record for Characterization of wound monitoring systems used to quantify and locate plutonium contamination (opens in a new tab)

  14. Resolution enhancement of coaxial, high-purity, Ge gamma-ray detectors

    … of the energy resolution of high-purity, Ge (HPGe), gamma-ray detectors was studied. In particular, circuits which correct for ballistic deficit and charge trapping were analyzed. Also, an equation from which energy line shapes can be calculated for arbitrary charge trap distributions and …

    utk-theses Repository record for Resolution enhancement of coaxial, high-purity, Ge gamma-ray detectors (opens in a new tab)

  15. DESIGN, DEVELOPMENT AND VALIDATION OF NOVEL ELECTRICAL CONTACTING SYSTEMS, MECHANICAL ENCAPSULATION SOLUTIONS AND HIGH-RESOLUTION INTEGRATED CHARGE-SENSITIVE PREAMPLIFIERS FOR ADVANCED HIGH-PURITY GERMANIUM DETECTORS

    … aimed at designing a new generation of segmented HPGe detectors while simultaneously building the in-house expertise required to develop, operate and maintain them independently. Within this framework, this PhD research provides several original contributions. First, an innovative and flexible …

    milano Repository record for DESIGN, DEVELOPMENT AND VALIDATION OF NOVEL ELECTRICAL CONTACTING SYSTEMS, MECHANICAL ENCAPSULATION SOLUTIONS AND HIGH-RESOLUTION INTEGRATED CHARGE-SENSITIVE PREAMPLIFIERS FOR ADVANCED HIGH-PURITY GERMANIUM DETECTORS (opens in a new tab)

  16. Characterization of LaBr₃:Ce detectors in a gamma-gamma coincidence configuration

    … provide relative to high-purity germanium (HPGe) detectors. Measurements have been made in both single and coincident detector configurations with both detector technologies to quantify the performance of each detector configuration permutation. Timing performance and optimization of single …

    texas Repository record for Characterization of LaBr₃:Ce detectors in a gamma-gamma coincidence configuration (opens in a new tab)

  17. Improvement of a detection system for in-vivo Al measurements, and in-vivo Al measurements of a population of miners.

    … a semi-conductor, a single closed-end coaxial HPGe. MDLs for these detectors were found to be 15.85 μgAl/gCa (236.17 μgAl) for the 4π NaI(Tl) system, 56.51 μgAl/gCa (842.0 ugAl) for the HPGe and 98.67 μgAl/gCa (1470.20 μgAl) for the LaBr3(Ce). The next part of the thesis involved in-vivo …

    mcmaster Repository record for Improvement of a detection system for in-vivo Al measurements, and in-vivo Al measurements of a population of miners. (opens in a new tab)

  18. Characterization of ²³⁹Pu with coincidence and anticoincidence methods

    … was comprised of two electrically cooled Ortec HPGe detectors, making the system highly transportable. With this detection method, ²³⁹Pu can be identified in environments with high background. Gamma-gamma coincidence provides data on whether ²³⁹Pu exists in a sample. Compton suppression, …

    texas Repository record for Characterization of ²³⁹Pu with coincidence and anticoincidence methods (opens in a new tab)

  19. The 14N(p,γ)15O reaction studied at low and high beam energy

    … the prompt photons were collected by a composite HPGe detector (at LUNA) or by up to four HPGe detectors (Dresden). The obtained results improve the fit of the excitation function in the R-matrix framework, that is used to extrapolate the S-factor at the very low astrophysical energies. In …

    qucosa-diss

Page 1 of 8