Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 50 for “"HPGe detectors"”
-
Characterization of Mechanically Cooled High Purity Germanium (HPGe) Detectors at Elevated Temperatures
… the use of hand-held high purity germanium (HPGe) in homeland security applications have centered on weight, geometry, and cool-down time. Typical liquid nitrogen cooled detectors ranging in size from 10% to 150% detectors will cool down sufficiently within 2-6 hours of filling. The cool-down …
-
Digital Signal Processing for segmented HPGe Detectors, Preprocessing Algorithms and Pulse Shape Analysis
… of 24 longitudinally six-fold segmented HPGe detectors, build for the efficient detection of rare decays in nuclear reactions of radioactive ion beams. MINIBALL was the first spectrometer equipped with digital electronics. Pulse shape analysis algorithms to determine the interaction …
-
Search for double beta decay with HPGe detectors at the Gran Sasso underground laboratory
… experiment collected data with enriched 76Ge detectors from 1990 to 2003. An improved analysis of Heidelberg-Moscow data is presented, exploiting new calibration and spectral shape measurements with the HdM detectors. Genius-Test-Facility was a test-facility that verified the feasibility of …
-
Surface Alpha Interactions in P-Type Point-Contact HPGe Detectors: Maximizing Sensitivity of 76Ge Neutrinoless Double-Beta Decay Searches
… point-contact (P-PC) high-purity Germanium (HPGe) detectors enriched in 76Ge, operated in large low-background arrays. This approach is used, with some key differences, by the MAJORANA and GERDA Collaborations. A problematic background in such large granular detector arrays is posed by alpha …
-
The prediction equations of the male and female chest wall thickness for measuring actinides within the lungs using HPGe detectors
… three- or six-detector hyperpure germanium (HPGe) array, for measuring actinides within the lungs. Presently, there is not a gender-specific CWT prediction equation derived for HPGe detection systems. The majority of the U.S. Department of Energy lung counting facilities are using HPGe …
-
3D characterization of multi-segmented HPGe detectors : simulation and validation of the PSCS technique and its application for different energies with a 152 Eu source
Les ensembles de détecteurs de rayon gamma de nouvelle génération, tel AGATA, utilisent des détecteurs multi-segmentés de germanium hyper-pur dans les expériences de physique nucléaire pour lesquelles une grande résolution et efficacité sont demandées. Ces caractéristiques sont obtenues par …
-
Efficiency optimization of a HPGe clover array for implantation decay experiments at FRIB
… gamma ray detector array with a small, planar HPGe detector to study some of the most exotic nuclei. This project focused on ensuring that this combination would maintain or improve the photon efficiency of a clover style array on its own, as well as optimizing the size of the planar HPGe …
-
Characterisation and Modelling of High Purity Germanium Detectors for the LEGEND Experiment and Beyond
… with ∼200 kg of High Purity Germanium (HPGe) detectors enriched in ⁷⁶Ge. An accurate understanding of these HPGe detectors is paramount to LEGEND’s success and achieved through dedicated characterisation measurements. This thesis is composed of three distinct research projects, the first …
-
Characterization of LaBr₃:Ce detectors in a gamma-gamma coincidence configuration
… doped lanthanum bromide (LaBr₃:Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr₃:Ce detectors provide relative to high-purity germanium …
-
Study of neutron induced reactions in rare earth isotopes
… measured through gamma-ray spectroscopy using HPGe detectors. For the accurate physics interpretation of the experimental data the GEANT4 toolkit was extensively used for the simulation of the HPGe detectors. The developed codes were utilized in the data analysis for the determination of the …
-
Study of the 20Ne(p,g)21Na reaction rate using the DRAGON recoil spectrometer coupled with GRIFFIN gamma-ray detectors at TRIUMF
… and 6 GRIFFIN high purity germanium (HPGe) detectors. The HPGe detectors provide superior energy resolution in the gamma-ray spectra compared to the typical bismuth germanate (BGO) detectors used at DRAGON and enable the clear separation of gamma-ray transitions of close energies. Two …
-
Design and Setup of a New HPGe Detector Based Body Counter Capable of Detecting Also Low Energy Photon Emitters
… of a new body-counter system based on HPGe detectors and installed at IVM of KIT. The goal, achieved, was the improvement of the ability to detect internal contaminations in the human body, especially the ones concerning low-energy emitters and multiple nuclides. The development of the …
-
Pulse Shape Analysis for the GERDA Experiment to Set a New Limit on the Half-life of Neutrinoless Double Beta Decay of Ge-76
… decay of Ge-76 using high purity germanium (HPGe) detectors operated in liquid argon (LAr). The aim is to explore half-lives of the order of 10^26 yr. Therefore, GERDA relies on improved active background reduction techniques such as pulse shape discrimination (PSD) in which the time …
-
A new method for the determination of the entry position of y-rays [gamma rays] in high purity germanium detectors by current pulse analysis
… the entry point of gamma-rays in closed ended HPGe detectors has been developed. Exploiting the position dependence shown by the current pulses generated when a gamma-ray interacts with the detector, it is possible to electronically divide the crystal in the radial coordinate and thus increase …
-
Fission product yield measurements using a fission-spectrum neutron beam at a research reactor
… was performed using two high purity germanium (HPGe) detectors. The project aims to develop these techniques to reduce the uncertainty of fission yields for short-lived fission products of interest for post-detonation nuclear forensics.
-
Thermal neutron analysis for improvised explosive device detection
… IEDs within between 15.6 and 3800 seconds for HPGe detectors, and within 277 seconds for the best case scenario with NaI while more deeply buried explosives are shown to be undetectable by NaI.
-
Decay spectroscopy of 178Au
… investigated through decay spectroscopy. Si and HPGe detectors were utilised to analyse the decay radiation of 178 Au and its daughter nuclei. Previous studies have been unable to distinguish decay radiation from different isomeric states of this nucleus. This thesis represents the first time …
-
The 14N(p,γ)15O reaction studied at low and high beam energy
… the prompt photons were collected by a composite HPGe detector (at LUNA) or by up to four HPGe detectors (Dresden). The obtained results improve the fit of the excitation function in the R-matrix framework, that is used to extrapolate the S-factor at the very low astrophysical energies. In …
-
Laser Spectroscopy Of Neutron-Deficient Bismuth Isotopes
… implanted into carbon foils with silicon (Si) detectors used to measure alpha decays and high purity germanium (HPGe) detectors used to measure gamma decays. The alpha decay schemes of the ground state and the isomeric state of Bi were derived from the Si energy spectra. By doing this, the …
Page 1 of 3