Showing 1 to 20 of 69 for “"HR-pQCT"”.
-
Investigating Bone Remodelling in Knee Osteoarthritis using HR-pQCT Imaging
Osteoarthritis (OA) is the most common type of arthritis and a significant cause of disability worldwide. With an aging population in Canada, the prevalence and burden of OA is expected to increase. Knee OA is the most common form of OA, comprising upwards of 30% of cases. Early-stage OA can be …
-
Quantitative analysis of bone microarchitecture in HR-pQCT images for fracture discrimination
… fracture risk assessment is carried out through dual-energy X-ray absorptiometry (DXA) imaging, high-resolution peripheral quantitative computed tomography (HRpQCT) is becoming increasingly available, providing more detailed analysis of bone microarchitecture at the peripheral skeleton. …
-
Concurrent Assessment of Knee Cartilage Morphology and Bone Microarchitecture using Contrast-Enhanced HR-pQCT Imaging
Osteoarthritis (OA) is a prevalent articular disease characterized by degradation of articular cartilage and bone. Presently, no single imaging modality concurrently captures these changes. This study sought to develop and validate a novel joint imaging technique, contrast enhanced high resolution …
-
Using HR-pQCT and finite element analysis to inform clinical assessment of distal radius fractures
… peripheral quantitative computed tomography (HR-pQCT) allows for non-invasive in vivo assessment of bone density and stiffness throughout the fracture healing process, which may inform fracture healing progression and cast removal. Many fracture assessment instruments have been developed for …
-
The assessment of fragility fracture risk using HR-pQCT as a novel tool for diagnosis of osteoporosis
… peripheral quantitative computed tomography (HR-pQCT) is a medical imaging modality capable of characterizing three-dimensional bone microarchitecture at peripheral skeletal sites, and has demonstrated that bone microarchitecture can improve prediction of fracture risk. However, to date the …
-
Effect of Vitamin D and Whole Body Vibration on High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) Parameters of the Distal Tibia
… bone density of the distal tibia as measured by HRpQCT. The study consisted of four parallel groups of equal numbers (40 in total); WBV and placebo group, placebo group, vitamin D group and vitamin D+ WBV group. Measurements (HR-pQCT, serum 25 (OH)D, PTH, bone profile) were collected at baseline …
-
Novel prediction tools for bone health assessment in adults
… peripheral quantitative computed tomography (HR-pQCT) has shown promise in improving fracture stratification through detailed measures of bone microarchitecture. Nonetheless, improvements to date have been modest. The aim of this dissertation was to develop and evaluate new methodologies for …
-
A TRI-MODALITY COMPARISON OF VOLUMETRIC BONE MEASURE QUANTIFICATION USING 1.0 TESLA PERIPHERAL MAGNETIC RESONANCE IMAGING, PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND HIGH-RESOLUTION-PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY IMAGES
… study of peripheral (p) QCT, high-resolution pQCT (hr-pQCT) and 1.0 Tesla pMRI technologies quantified short-term test-retest reproducibility, validity, one-year detection limit and clinical sensitivity of each modality’s derived bone measures. Select bone outcomes were evaluated from scans …
-
Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis
Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but …
-
Using Advanced Medical Imaging to Study Bone and Joint Changes in Rheumatoid Arthritis
Inflammatory processes in rheumatoid arthritis (RA) lead to the damage of joints which results in functional decline. Medical imaging plays an important role in evaluating the onset and progression of RA. High resolution peripheral quantitative computed tomography (HR-pQCT) permits 3-dimensional …
-
Monitoring Bone Micro-architecture with a Special Focus on Bone Strength
Introduction. Osteoporosis is a chronic disease characterized by the loss of bone mass and the deterioration of bone micro-architecture leading to a subsequent increase in fracture risk. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides non-invasive measures of bone …
-
Development of Novel Automated Methods for Quantitative Analysis of Bone with High-Resolution Peripheral Computed Tomography and Application to Investigate Bone Changes Following ACL Injury
Knee osteoarthritis (OA) is a prolific and devastating disease. The processes leading to the development of OA are poorly understood, but periarticular bone adaptations are theorized to play an important role. High-resolution peripheral quantitative computed tomography (HR-pQCT) can resolve human …
-
Using High Resolution Peripheral Quantitative Computed Tomography to Evaluate Bone Health and Relative Energy Deficiency in Sport Risk in Elite Winter Sport Athletes
… peripheral quantitative computed tomography (HR-pQCT) measures volumetric BMD (vBMD), microarchitecture, geometry, and estimated strength reported as failure load. The objective of this study was to assess the differences in bone parameters using HR-pQCT in elite winter sport athletes …
-
Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling
… peripheral quantitative computed tomography (HR-pQCT) images; however, these models are limited because they determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an outstretched hand. The objective of this research was to …