Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 133 for “"HVDC systems"”

  1. Fault Detection and Restoration for Hybrid HVDC Systems

    … existing AC grids, high voltage direct current (HVDC) systems are being built in many countries around the world. HVDC lines are used for bulk power transmission over long distances with low power losses and high security, reliability, and system stability. With the development of various HVDC …

    waterloo Repository record for Fault Detection and Restoration for Hybrid HVDC Systems (opens in a new tab)

  2. DC fault detection and clearance in VSC-HVDC systems

    … (VSC) has paved way for the emergence of VSC-HVDC transmission systems opening up the possibility to build multi-terminal DC (MTDC) grid in future. Before we reach that mark, there are a lot of open points to be answered. One of the critical topics for such DC grid is the protection. DC fault …

    nanyang Repository record for DC fault detection and clearance in VSC-HVDC systems (opens in a new tab)

  3. Modular Multilevel Converters in Hybrid Multi-Terminal HVDC Systems

    High-voltage direct current (HVDC) systems are becoming commonplace in modern power systems. Line commutated converters (LCCs) are suitable for bulk power and ultra-HVDC (UHVDC) transmission, while with inflexible power reversal capability and possible commutation failures. However, voltage source …

    unsw Repository record for Modular Multilevel Converters in Hybrid Multi-Terminal HVDC Systems (opens in a new tab)

  4. Insulation Resistance Monitoring for HVDC systems in automotive applications

    ABSTRACT As electric vehicle and renewable-energy systems push toward ever-higher voltages, reliable insulation resistance monitoring (IRM) becomes critical to ensure safety, prevent insulation degradation, and maintain system availability. Key IRM performance parameters include common-mode and …

    chalmers Repository record for Insulation Resistance Monitoring for HVDC systems in automotive applications (opens in a new tab)

  5. Control and application of VSC-HVDC systems for grid connection

    … from power generation centers to different AC systems or between AC systems. From the technical and economical viewpoint, VSC-HVDC transmission has a number of potential advantages and applications. For example, VSCHVDC can control the active and reactive power independently and the power flow …

    ets-quebec

  6. Parallel Tapping LCC-HVDC Systems with Multiple Modular Multilevel Converters

    … power from existing high voltage direct current (HVDC) transmission lines to minimize the infrastructure cost in electrifying rural communities. The vast majority of the previous research has focused on tapping schemes utilizing line commutated converter (LCC) based technologies that have …

    alberta Repository record for Parallel Tapping LCC-HVDC Systems with Multiple Modular Multilevel Converters (opens in a new tab)

  7. Small signal impedance modelling and stability assessment of HVDC systems

    … and distributed generation, and increased use of HVDC interconnections, the characteristics of power systems is undergoing significantly changes. Interaction between grid-connected converters and networks is likely to increase, which may lead to stability and resonance problems, and in particular, …

    strathclyde Repository record for Small signal impedance modelling and stability assessment of HVDC systems (opens in a new tab)

  8. Investigation of Reactive Power Control and Compensation for HVDC systems

    … the mechanism of reactive power compensation for HVDC systems, and develop guidelines for the design of reactive power compensation schemes for HVDC systems. The capabilities of various reactive power compensators to enhance power system stability are compared in both steady and transient states. …

    manitoba Repository record for Investigation of Reactive Power Control and Compensation for HVDC systems (opens in a new tab)

  9. Reliability assessment of HVdc systems using Monte Carlo simulation technique

    With the proliferation of HVdc systems around the world, the reliability performance of HVdc system and the impact of HVdc systems on the reliability performance of overall power systems is becoming an important issue. In the past, predominantly analytical techniques were used to assess the …

    manitoba Repository record for Reliability assessment of HVdc systems using Monte Carlo simulation technique (opens in a new tab)

  10. Artificial neural network and fuzzy logic control for HVDC systems

    … the control of the high voltage direct current (HVdc) systems. The studies considered their implementation in both low and high level control systems in HVdc systems. The study is verified using the electromagnetic transients simulation software. The results demonstrated successful performance …

    manitoba Repository record for Artificial neural network and fuzzy logic control for HVDC systems (opens in a new tab)

  11. An integrated simulation and control implementation environment for HVDC systems

    A control system for the control of HVDC, SVC and other FACTS devices can be developed, tested and debugged using an electromagnetic transients simulation program. The thesis presents a procedure for the direct conversion of this developed emtp-type model into the control language for a real world …

    manitoba Repository record for An integrated simulation and control implementation environment for HVDC systems (opens in a new tab)

  12. Reliability of Power Electronic Systems in HEV and HVDC Systems

    With wide-spread application of power electronic systems across many different industries, their reliability is being studied extensively. In the dissertation, a mission profile based reliability analysis framework is proposed to quantitatively predict the reliability of power electronic systems. …

    msu

  13. FACTS and HVDC systems for enhancing tie-line power transfer capability

    … investigates the use of flexible AC transmission systems (FACTS) and voltage source converter (VSC) high-voltage direct current (HVDC) transmission systems for improving the power transfer capability of the Libyan internal tie-line between east and west, for a secure, reliable and efficient …

    strathclyde Repository record for FACTS and HVDC systems for enhancing tie-line power transfer capability (opens in a new tab)

  14. Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems

    … (RESs) are being integrated into the power systems. The transfer of renewable power generated by the RESs such as offshore wind farms to remote load centers may require the use of direct current (DC) lines, which are connected to the alternating current (AC) grid via AC-DC converters. In …

    waterloo Repository record for Control Loop Interactions and Their Mitigation Schemes in VSC-HVDC Systems (opens in a new tab)

  15. Travelling Wave Based DC Line Fault Location in VSC HVDC Systems

    … (LCC) based high voltage direct current (HVDC) transmission lines, but the large capacitors at the DC line terminals makes application of the same techniques for voltage source converter (VSC) based HVDC schemes challenging. A range of possible signals for detecting the fault generated …

    manitoba Repository record for Travelling Wave Based DC Line Fault Location in VSC HVDC Systems (opens in a new tab)

  16. Operating limits and dynamic average-value modelling of VSC-HVDC systems

    … operating limits of high-voltage direct-current (HVDC) transmission systems that employ voltage-source converters (VSCs) as their building blocks. This scheme is commonly known as the VSC-HVDC transmission. A simulation-based study is undertaken in which detailed electromagnetic transient (EMT) …

    manitoba Repository record for Operating limits and dynamic average-value modelling of VSC-HVDC systems (opens in a new tab)

  17. Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems

    … to quantify the complex interactions between HVDC transmission schemes in a multi-infeed configuration, particularly with regard to the voltage interactions and the commutation failure phenomena. The in-depth analysis of multi-infeed HVDC systems discussed in this research shows the …

    manitoba Repository record for Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems (opens in a new tab)

Page 1 of 7