  1. Delineating anomalous layers in soil profiles using seismic surface wave methods

    … carbonate-cemented layer, a high velocity layer (HVL), are commonly encountered in Las Vegas, Nevada and other arid settings. Knowledge of the presence, geometry and hardness of the carbonate-cemented inclusions is important for civil engineering site investigation. Active-source seismic surface …

    unlv Repository record for Delineating anomalous layers in soil profiles using seismic surface wave methods (opens in a new tab) Download PDF for Delineating anomalous layers in soil profiles using seismic surface wave methods (opens in a new tab)

  2. Effect of PRRSV2 on tight junctions in the porcine maternal-fetal interface

    … and CTRL/PRRSV2-infected high viral load (HVL) groups using a 2 x 2 factorial approach, and secondly across disease progression groups by comparing CTRL, UNIF, HVL-VIA fetuses, and HVL MEC in the body (HVL-MEC-B) fetuses. In non-infected CTRL, immunostaining for TJP1 was consistent and …

    sask Repository record for Effect of PRRSV2 on tight junctions in the porcine maternal-fetal interface (opens in a new tab)

  3. PORCINE REPRODUCTIVE AND RESPIRATORY SYNDROME VIRUS: PATHOLOGICAL EFFECTS ON THE PLACENTA AND TRANSPLACENTAL TRANSMISSION

    … only infected (PLCO), high viral load viable (HVL-VIA), and HVL-meconium stained (MEC) from PRRSV-infected gilts, as well from sham-inoculated (CON) gilts. Finally, potential factors related to PRRSV2 localization, including the severity of inflammation in endometrium and placenta, and …

    sask Repository record for PORCINE REPRODUCTIVE AND RESPIRATORY SYNDROME VIRUS: PATHOLOGICAL EFFECTS ON THE PLACENTA AND TRANSPLACENTAL TRANSMISSION (opens in a new tab)

  4. Μελέτη υποπληθυσμών Τ-λεμφοκυττάρων σε πλακουντιακό ιστό γυναικών με χρόνια Ηπατίτιδα Β. Συσχέτιση με τα επίπεδα ιαιμίας της μητέρας κατά την περιγεννητική περίοδο

    … και της ομάδας των εγκύων με υψηλό ιικό φορτίο (HVL, High Viral Load). Υλικά και Μέθοδοι: Για την υλοποίηση της μελέτης χρησιμοποιήθηκαν 53 δείγματα πλακουντιακού ιστού και εφαρμόστηκαν τρεις μέθοδοι για την ανάλυσή τους: ιστοχημική χρώση Αιματοξυλίνης-Ηωσίνης, ανοσοϊστοχημεία (HBsAg HBcAg, …

    athens Repository record for Μελέτη υποπληθυσμών Τ-λεμφοκυττάρων σε πλακουντιακό ιστό γυναικών με χρόνια Ηπατίτιδα Β. Συσχέτιση με τα επίπεδα ιαιμίας της μητέρας κατά την περιγεννητική περίοδο (opens in a new tab)

  5. Development and Validation of Precision in Small Animal Radiotherapy Dose Monitoring

    … Many comparison studies use half value layer (HVL) measurements to match TLD calibration curves to dose measurements. The dissertation will determine the appropriateness of the use of HVL as a normalizing factor for polychromatic x-ray beams.</p><p>In addition to current dosimeter technology, …

    duke Repository record for Development and Validation of Precision in Small Animal Radiotherapy Dose Monitoring (opens in a new tab)

  6. Population genetic study for evaluating the differentiation and gene flow among Eastern Mediterranean strains of the Leishmania donovani complex

    … MON-1 is the main causative agent of human (HVL) and canine visceral leishmaniasis (CanL), and occasionally of human cutaneous leishmaniasis (HCL) in this area. The evident re-emergence of cases in classical endemic foci and reports of imported or autochthonous cases in formerly non-endemic …

    fu-berlin Repository record for Population genetic study for evaluating the differentiation and gene flow among Eastern Mediterranean strains of the Leishmania donovani complex (opens in a new tab)

  7. Photoactive Nanofibers Embedded with Lanthanide Nanoparticles for Wound Dressing

    … light. The photolabile conjugated drug (hvL-PEG) and UCNPs were embedded in electrospun and crosslinked PVA fibers as a model system for a wound healing dressing. The UCNP/hvL-PEG electrospun fibers show high antibacterial activity against the Gram-positive bacteria Staphylococcus aureus …

    concordia Download PDF for Photoactive Nanofibers Embedded with Lanthanide Nanoparticles for Wound Dressing (opens in a new tab)

  8. Spectra of scattered radiation at points off the beam axis

    … for two qualities of X-rays, 280 KVP, HVL of 2.5 mm Cu and 140 KVP, HVL of 1.45 mm Al. A circular beam of 100 cm2 at FSD of 60 cm was used. Measurements were carried out at 5 cm depth for 280 KVP and 2 cm depth for 140 KVP. It was found that for 280 KVP radiation, the shapes of the …

    sask Repository record for Spectra of scattered radiation at points off the beam axis (opens in a new tab)

  9. X-Ray Beam Characteristics And Radiation Dose Deposition To Soft Tissue From Fluoroscopic X-Ray Beams Incorporating Copper Filtration

    … beam characteristics of first half-value layer (HVL), second HVL, homogeneity coefficients (HCs), and backscatter factors (BSFs) across the full range of available beam qualities; and third, it investigated the energy dependence of kerma-area-product (KAP)-meters measuring the radiation output of …

    wayne-thes Repository record for X-Ray Beam Characteristics And Radiation Dose Deposition To Soft Tissue From Fluoroscopic X-Ray Beams Incorporating Copper Filtration (opens in a new tab)

  10. An X-ray Source Model and Characterization Method for Computing kV Radiation Dose

    … potential (kVp) and half-value layer (HVL). These are matched to spectra generated by third-party freeware. The fluence is then isolated from measured in-air kerma. We assume that the fluence is a function of three separate independent variables: the transverse-axis spectra; and the …

    calgary Repository record for An X-ray Source Model and Characterization Method for Computing kV Radiation Dose (opens in a new tab)

  11. Monte Carlo Analysis and Physics Characterization of a Novel Nanoparticle Detector for Medical and Micro-dosimetry Applications

    … that soft x-ray beams (160 kV at 0.62 mm Cu HVL and 320 kV at 1 mm Cu HVL) lead to substantially higher dose to BM within close proximity to mineral bone (within about 60 µm) as compared to hard x-ray beams (320 kV at 4 mm Cu HVL) and isotope based gamma irradiators (137Cs). The average dose …

    duke Repository record for Monte Carlo Analysis and Physics Characterization of a Novel Nanoparticle Detector for Medical and Micro-dosimetry Applications (opens in a new tab)

  12. The special distribution of X-rays scattered within a water phantom

    … rays in bone and soft tissue for 400 KVP X-rays, HVL 3.8 mm of Cu.

    sask Repository record for The special distribution of X-rays scattered within a water phantom (opens in a new tab)

  13. Evaluation of absorbed dose and image quality in mammography

    … for characterisation of the X-ray beam (HVL=half value layer) specified in the European protocol. In an experimental setup, it was shown that non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated semiconductor detector with simultaneous …

    lund Repository record for Evaluation of absorbed dose and image quality in mammography (opens in a new tab) Download PDF for Evaluation of absorbed dose and image quality in mammography (opens in a new tab)

  14. Subjective Evaluation of the In-Line Phase-Sensitive Imaging Systems in Breast Cancer Screening and Diagnosis

    … approach for estimating the half-value-layer (HVL) from measured or simulated x-ray spectra. The HVL measurement is expected to be less accurate or experimentally challenging in some clinical equipment or when a quick beam quality evaluation is needed. Additionally, the impact of varying …

    oklahoma-thes Repository record for Subjective Evaluation of the In-Line Phase-Sensitive Imaging Systems in Breast Cancer Screening and Diagnosis (opens in a new tab)

  15. Using Deep Learning and Macroscopic Imaging to Predict the Uniaxial Stress-Strain Response of Glutaraldehyde-Fixed Porcine Aortic Heart Valve Leaflets

    … mechanical testing of heart valve leaflets (HVLs) is the standard for evaluating mechanical behavior, it is time-intensive, tedious, technical, and requires specialized and expensive equipment. On the other hand, computational resources and imaging are readily available and more …

    rice Repository record for Using Deep Learning and Macroscopic Imaging to Predict the Uniaxial Stress-Strain Response of Glutaraldehyde-Fixed Porcine Aortic Heart Valve Leaflets (opens in a new tab)

  16. Untersuchung von Adenohypophysentumoren auf ihre quantitative und qualitative IL-6 Sekretion sowie dessen Einfluß auf die Wachstumshormonausschüttung

    Aus 42 eingeschickten HVL-Adenomen wurden nach standardisiertem Schema Zellkulturen angelegt und diese Kulturen auf ihre IL-6 Basalsekretion (40) sowie 33 Kulturen auf ihr Ansprechen auf verschiedene Faktoren in ihrer Cytokinsekretion hin untersucht. 9 somatotrope Zellkulturen wurden auf ihre …

    lmu-germany Repository record for Untersuchung von Adenohypophysentumoren auf ihre quantitative und qualitative IL-6 Sekretion sowie dessen Einfluß auf die Wachstumshormonausschüttung (opens in a new tab)

  17. Measurements of cell survival at low doses of radiation

    … at lower doses. A Picker X-ray source (280 kVp, HVL 1.7 mm Cu) was used for these experiments. The choice of a survival model has important implications in the low dose region. The predictions of three different survival models regarding the effect of oxygen at low doses are discussed. This …

    ubc Repository record for Measurements of cell survival at low doses of radiation (opens in a new tab) Download PDF for Measurements of cell survival at low doses of radiation (opens in a new tab)

  18. OPTIMIZATION OF DEDICATED BREAST COMPUTED TOMOGRAPHY: BOWTIE FILTER DESIGN AND OPTIMAL SPECTRUM ANALYSIS

    … designs was done by calculating/measuring the HVL, intensity, and µeff behind the phantom as a function of fan-angle. The performance of the designs depended only weakly on incident spectrum and tissue composition. With various breast diameters, the calculated parameters varied the most, but …

    maryland Repository record for OPTIMIZATION OF DEDICATED BREAST COMPUTED TOMOGRAPHY: BOWTIE FILTER DESIGN AND OPTIMAL SPECTRUM ANALYSIS (opens in a new tab)

  19. Determination of the bremsstrahlung spectra of a clinical linear accelerator using a Simpson iteration technique

    … as opposed to the interpolated 18 MV model. The HVL data also suggests that the modal energy of the beam is substantially larger than 1 MeV. The disagreement of all the above models leads the author to conclude that further work and unification of methodology is needed to verify true photon …

    ut-knoxville Repository record for Determination of the bremsstrahlung spectra of a clinical linear accelerator using a Simpson iteration technique (opens in a new tab)