  1. System Identification and Calibration Techniques for Force Measurement in Active Magnetic Bearings

    … of magnetic flux density as provided by a Hall probe inserted in the magnetic field. In this work, a system identification approach to force measurement is proposed; the proposed approach is applicable to all active magnetic bearings and does not require Hall probes. Recent developments in …

    vt Repository record for System Identification and Calibration Techniques for Force Measurement in Active Magnetic Bearings (opens in a new tab)

  2. Development of graphene-based sensors for scanning Hall microscopy and imaging of vortex matter in unconventional superconductors

    … graphene could become incorporated into is the Hall-effect magnetic field sensor. Within this project CVD graphene Hall probes with wire widths from 1.5mu m down to 50nm have been fabricated and characterised to explore the possibility of replacing III-V semiconductor-based 2D electron gas Hall …

    bath Repository record for Development of graphene-based sensors for scanning Hall microscopy and imaging of vortex matter in unconventional superconductors (opens in a new tab)

  3. Study of a ferromagnetic semiconductor by the scanning Hall probe microscope

    … goal of my dissertation was to build a Scanning Hall Probe Microscope (SHPM) for studying the domain structure of a ferromagnetic semiconductor (Ga[subscript 0.94]Mn[subscript 0.06]). This new semiconductor may be used in the emerging field of spintronics, where both the charge and spin of an …

    texas Repository record for Study of a ferromagnetic semiconductor by the scanning Hall probe microscope (opens in a new tab)

  4. A Study of Stray Load Losses in Core Clamp Plates of Salient Pole Synchronous Machines

    … plate surfaces pre extensively examined using Hall probes. Hell probe: instrumentation end date handling by computer, is presented, the clamp plate surface flux densities ere obtained with both a.c. and d.c. excitation. The waveforms of the surface flux densities are presented in detail, end …

    aston Repository record for A Study of Stray Load Losses in Core Clamp Plates of Salient Pole Synchronous Machines (opens in a new tab)

  5. The Contemporary Novel and the Brain

    … how the embodied mind and embrained body challenge traditional understandings of human knowledge, identity, and agency. Chapter 1 explores the influence of neo-Darwinian ideas about the brain on A. S. Byatt’s representations of language and memory. Chapter 2 follows by examining genetic …

    durham Repository record for The Contemporary Novel and the Brain (opens in a new tab)

  6. Electromagnetic measurements of steel phase transformations

    … was based on a dc electromagnetic E-core, with Hall probes in each of the three poles. 'Cold' calibration tests were used to decouple the steel and the lift-off. The results indicated that there was an error of 3-4% ferrite/mm at high ferrite fractions. At lower fractions the error was higher …

    durham Repository record for Electromagnetic measurements of steel phase transformations (opens in a new tab)

  7. An investigation of the magnetic field of full flux penetration of superconducting materials for radio-frequency cavities

    … dipole magnet, similar to that of an RF cavity. Hall probes measure both the applied and the penetrated field. The system underwent a rigorous commissioning process which indicated the system has a random error of 0.9 %. The facility has then been used to investigate new materials for SRF …

    lancaster Repository record for An investigation of the magnetic field of full flux penetration of superconducting materials for radio-frequency cavities (opens in a new tab)

  8. Measurements of Magnetic Field Penetration of Materials for Superconducting Radiofrequency Cavities

    … up to 500 mT at the sample surface and three Hall probes to detect the full flux penetration through the planner superconductor with 2 inch diameter. This setup was used to study alternative materials which could potentially outperform niobium, as well as SIS multilayer coatings on niobium.

    odu Repository record for Measurements of Magnetic Field Penetration of Materials for Superconducting Radiofrequency Cavities (opens in a new tab)

  9. Predicting the magnetic field of the three-meter spherical Couette experiment

    … flows of Earth. The experiment has 31 surface Hall probes measuring sparsely the external magnetic field. The numerical model, XSHELLS, solves the coupled Navier-Stokes and induction equations numerically to give a full picture of the internal velocity and magnetic field, however, it cannot …

    maryland Repository record for Predicting the magnetic field of the three-meter spherical Couette experiment (opens in a new tab)

  10. Rotating, hydromagnetic laboratory experiment modelling planetary cores

    … axial, DC magnetic field, we use a collection of Hall probes to measure the magnetic induction that results from interactions between the applied field and the flowing, conductive fluid. We have observed and identified inertial modes, which are bulk oscillations of the fluid restored by the …

    maryland Repository record for Rotating, hydromagnetic laboratory experiment modelling planetary cores (opens in a new tab)

  11. Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

    … scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, …

    odu Repository record for Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping (opens in a new tab)

  12. Austenite-Martensite phase transformation and magneto-mechanical studies on nickel manganese gallium single crystal alloy.

    … average magnetization where also made using Hall probes to measure the stray ¯eld produced by the specimen during these experiments. These results have some portions of the strain-magnetization curves that are linear, which is what is pre- dicted by models that have both of these quantities …

    umn Repository record for Austenite-Martensite phase transformation and magneto-mechanical studies on nickel manganese gallium single crystal alloy. (opens in a new tab)

  13. Development of nanoscale sensors for scanning Hall probe microscopy and investigations of novel vortex phases in highly anisotropic superconductors

    Bismuth Hall effect sensors with active sizes in the range 0.1µm - 2µm have been fabricated by electron beam lithography and lift-off techniques for applications in scanning Hall probe microscopy (SHPM). The key figures of merit of the sensors have been systematically characterised as a function of …

    bath Repository record for Development of nanoscale sensors for scanning Hall probe microscopy and investigations of novel vortex phases in highly anisotropic superconductors (opens in a new tab)

  14. Etudes magnétiques locales des supraconducteurs exotiques

    … été étudiés par magnétométrie locale à sonde de Hall. Nous avons tout d'abord construit les profils de champ magnétique dans les échantillons pour déterminer quand les premiers vortex pénètrent dans l'échantillon. La forme en dôme des profils a indiqué que le piègeage est très faible et que la …

    star-france Repository record for Etudes magnétiques locales des supraconducteurs exotiques (opens in a new tab)