Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Harmonic Filters"”.

  1. Rf Low Pass Filter Design And Fabrication Using Integrated Passive Device Technology

    … optimization of both the inductors and IPD harmonic filters. The effective use of EM simulation enables us to realize the successful development of high performance harmonic filters. To make the optimization be more flexible and also for a deeper understanding of the optimization theory, …

    ucf Repository record for Rf Low Pass Filter Design And Fabrication Using Integrated Passive Device Technology (opens in a new tab)

  2. Evaluations of energy efficiency improvement

    … thesis evaluations of energy efficiency based on harmonic impacts and improvement methods in order to obtain better harmonic performance have been investigated. Here, the impact of harmonics at the PCCs according to IEEE is studied. This work is based on the simulations of industrial furnaces by …

    chalmers Repository record for Evaluations of energy efficiency improvement (opens in a new tab)

  3. Controlling harmonic distortion in power electronics using active power filters

    … power conversion and control, but can generate harmonic distortion in the current that is being drawn. Harmonic distortion can have deleterious effects on the power system, degrading power quality, system performance, and efficiency. Active harmonic filters have gained attention due to the …

    umn Repository record for Controlling harmonic distortion in power electronics using active power filters (opens in a new tab)

  4. Instantaneous Power Theory for Active Filtering of High Displacement Power Factor Non-linear Loads

    … this technology is that drives are a source of harmonic currents. This work designs and models in PSCAD, an electrical system typically encountered in modern industrial operations, where the load is composed of a large percentage of voltage-source converter drives. Attempts are made to provide …

    manitoba Repository record for Instantaneous Power Theory for Active Filtering of High Displacement Power Factor Non-linear Loads (opens in a new tab)

  5. Effects of transmission line compensation and power factor correction on harmonic propagation

    … different levels, transmission and utilization. Harmonics injected at these levels can severely degrade the performance and long term reliability of the power system; At the utilization level, a typical industrial power system configuration that requires power factor capacitors and tuned harmonic …

    unlv Repository record for Effects of transmission line compensation and power factor correction on harmonic propagation (opens in a new tab) Download PDF for Effects of transmission line compensation and power factor correction on harmonic propagation (opens in a new tab)

  6. Solar activity detection and prediction using image processing and machine learning techniques

    … is developed by using multi-scale circular harmonic filters, Kalman filter and SVM. The method takes a sequence of consecutive Michelson Doppler Imager (MDI) magnetograms as the input. The multi-scale circular harmonic filters are applied to detect bipolar regions from the solar disk surface …

    njit Repository record for Solar activity detection and prediction using image processing and machine learning techniques (opens in a new tab)

  7. Strategic Harmonic Filter Placement In Electric Ship and Utility Power Systems

    … distortion in a power system because of the harmonic characteristics of the current they draw. Thus, the management of power quality is becoming increasingly vital to safe and efficient power system operation. To properly assess the flow of harmonic current in a power system, this …

    south-carolina Repository record for Strategic Harmonic Filter Placement In Electric Ship and Utility Power Systems (opens in a new tab)

  8. Projeto de filtros passivos para a redução de correntes harmônicas na subestação de 2x300 kVA da estação elevatória de água do Jiqui

    … do Rio Grande do Norte (CAERN). Divergent harmonic currents were observed against the standard recommendations, caused by the use of inverters for driving the motors. To solve this case, this final work presents passive harmonic filters single tuned to be instaled in parallel with the low …

    brazil-ufrn Repository record for Projeto de filtros passivos para a redução de correntes harmônicas na subestação de 2x300 kVA da estação elevatória de água do Jiqui (opens in a new tab)

  9. Peak Load Shaving and Power Quality Improvement for the Louis-Hippolyte-La Fontaine Tunnel in Montréal

    … finally, to implement the capabilities of active harmonic filters and harmonic mitigation techniques to suppress the harmonic content in the line current.

    concordia Download PDF for Peak Load Shaving and Power Quality Improvement for the Louis-Hippolyte-La Fontaine Tunnel in Montréal (opens in a new tab)

  10. Smart electronic loads for harmonic compensation in future electrical distribution systems

    Common solutions to mitigating harmonics and improving power quality of power systems would include installing dedicated passive or active harmonic filters at the point of common coupling (PCC). However, as the complexity of energy systems increases with integration of renewables and storage …

    ubc Repository record for Smart electronic loads for harmonic compensation in future electrical distribution systems (opens in a new tab) Download PDF for Smart electronic loads for harmonic compensation in future electrical distribution systems (opens in a new tab)

  11. Switching frequency reduction in pulse-width modulated multilever converters and systems

    … Systems (FACTS) controllers and active harmonic filters. They can reach high voltages with low harmonics without the use of transformers or series-connected synchronised switching devices by their unique structures. Along with proper Pulse-Width Modulation (PWM) control scheme, they can …

    glasgow Download PDF for Switching frequency reduction in pulse-width modulated multilever converters and systems (opens in a new tab)

  12. The investigation of correlator systems utilizing object and frequency space filters

    … invariant pattern recognition.<br/><br/>Circular harmonic matched filters and phase-only filters with different expansion orders are involved in the photorefractive JTC for real-time rotationally invariant pattern recognition. These filters can also be used to track an object with different …

    abertay Repository record for The investigation of correlator systems utilizing object and frequency space filters (opens in a new tab) Download PDF for The investigation of correlator systems utilizing object and frequency space filters (opens in a new tab)

  13. Improvement of resonant harmonic filter effectiveness in the presence of distribution voltage distortion

    Resonant harmonic filters (RHFs), are the most common devices installed in distribution systems for reducing distortion caused by harmonic generating loads. When such filters are applied in systems with a distorted distribution voltage their effectiveness may decline drastically. This dissertation …

    lsu-thes Repository record for Improvement of resonant harmonic filter effectiveness in the presence of distribution voltage distortion (opens in a new tab)

  14. Harmonic distortion analysis involving submarine cables for offshore wind power plants

    … OWPPs often use converters that produce harmonics, and reactive components such as long high voltage AC (HVAC) submarine export cables further influence the harmonic content seen at the PCC. This thesis looks at voltage harmonics up to the 63rd order at the PCC between an OWPP and the …

    chalmers Repository record for Harmonic distortion analysis involving submarine cables for offshore wind power plants (opens in a new tab)

  15. Numerically efficient models of modular multilevel converters for high voltage direct current transmission system and AC-DC super grid

    … enhancement in weak AC grids. Additionally, harmonic filters are unnecessary in the implementation of MMC as it provides nearly perfect sinusoidal shape waveforms with a sufficient number of levels and switches. In recent years, various projects are developed based on the MMC-HVDC, and it …

    ubc Repository record for Numerically efficient models of modular multilevel converters for high voltage direct current transmission system and AC-DC super grid (opens in a new tab) Download PDF for Numerically efficient models of modular multilevel converters for high voltage direct current transmission system and AC-DC super grid (opens in a new tab)

  16. Optimal Harmonic Filter Topology Applied in HV and EHV Networks Using Particle Swarm Optimization

    Passive shunt harmonic filter banks have proven to be an effective method for reducing harmonic distortion in high-voltage and extra high-voltage networks, while providing the necessary volt-ampere-reactive power support and voltage support. Previous work in this area has provided information …

    uab Repository record for Optimal Harmonic Filter Topology Applied in HV and EHV Networks Using Particle Swarm Optimization (opens in a new tab)

  17. Modelling and analysis of electric arc loads using harmonic domain techniques

    … non-linear behaviour with the capacity to export harmonic distortion and flicker into the power system. Electric arc furnace installations, in particular, are well-known to be sources of dynamic disturbances affecting neighbouring loads. Arc discharge lamps, on aggregate, may exhibit the same …

    glasgow Download PDF for Modelling and analysis of electric arc loads using harmonic domain techniques (opens in a new tab)

  18. Mitigation of harmonic and inter-harmonic effects in nonlinear power converters

    Harmonic distortions are inevitably caused by a rectifier and an inverter due to their inherent nonlinearities. An AC-DC-AC converter, configured by the series connection of a rectifier, DC link, and an inverter, induces harmonic distortions at both AC sides and at the DC link. These harmonics can …

    texas Repository record for Mitigation of harmonic and inter-harmonic effects in nonlinear power converters (opens in a new tab)

  19. Ανάπτυξη τοπολογίας προσαρμοστικού ελέγχου διεργασιών πλοίων με ρυθμιστές στροφών για εξοικονόμηση ισχύος και καυσίμου γεννητριών

    … methodology is proposed to dimension appropriate harmonic filters, considering the source short circuit capacity and the existing vessel’s power system harmonics. The proposed system is retrofitted in a typical tanker vessel and the obtained experimental results are compared to previous operating …

    greece Repository record for Ανάπτυξη τοπολογίας προσαρμοστικού ελέγχου διεργασιών πλοίων με ρυθμιστές στροφών για εξοικονόμηση ισχύος και καυσίμου γεννητριών (opens in a new tab)

  20. Design of High-Density Filter Building Blocks for SiC-based Three-Phase Power Converters

    … components such as DC-link capacitors and line harmonic filters. Unfortunately, with faster switching speeds and high slew rates, the common-mode (CM) and differential-mode (DM) conducted emissions interference (EMI) noise is worsened. The effects are manifested at the utility interface with …

    vt Repository record for Design of High-Density Filter Building Blocks for SiC-based Three-Phase Power Converters (opens in a new tab)

Page 1 of 2