Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Head Biomechanics"”

  1. The Development and Application of a Forearm Simulator to Investigate Radial Head Biomechanics

    … a complex articular unit, with poorly understood biomechanics. A novel forearm simulator to facilitate physiologic testing of cadavers for multiple clinical scenarios was designed, manufactured and validated. A number of outcome measurements were potentiated including the forearm’s resistance to …

    uwo Repository record for The Development and Application of a Forearm Simulator to Investigate Radial Head Biomechanics (opens in a new tab)

  2. HUMAN OPTIC NERVE HEAD BIOMECHANICS : FINITE ELEMENT SIMULATIONS AND IN VIVO TISSUE STIFFNESS MEASUREMENTS

    … by the axon damage at the optic nerve head (ONH) and is associated with elevated intraocular pressure (IOP). However, patients show different sensitivity to changes in IOP, which implies the potential role of the biomechanical properties of ONH tissues in the progression of glaucoma. …

    nus Repository record for HUMAN OPTIC NERVE HEAD BIOMECHANICS : FINITE ELEMENT SIMULATIONS AND IN VIVO TISSUE STIFFNESS MEASUREMENTS (opens in a new tab)

  3. Finite element modeling of optic nerve head biomechanics in a rat model of glaucoma

    … biomechanical insult to the optic nerve head (ONH), the region in the posterior eye where RGC axons exit, is key to glaucoma pathophysiology, the mechanisms by which biomechanical insult leads to RGC death are unknown. Rat glaucoma models present an opportunity for understanding glaucoma …

    gatech Repository record for Finite element modeling of optic nerve head biomechanics in a rat model of glaucoma (opens in a new tab)

  4. Applications of ex vivo and in vivo ultrasound imaging techniques for the characterization of cornea, retina, sclera, and optic nerve head biomechanics

    … and the eventual loss of vision. Altered biomechanics in the corneal stroma at the front of the eye are implicated in the progression of corneal ectasia. Mechanical and downstream biochemical factors in the sclera and optic nerve head are suspected to cause optic neuropathy. To maintain …

    ohiolink Repository record for Applications of ex vivo and in vivo ultrasound imaging techniques for the characterization of cornea, retina, sclera, and optic nerve head biomechanics (opens in a new tab)

  5. Magnetic Resonance Elastography of the Brain: from Phantom to Mouse to Man

    … provide parameters for numerical models of human head biomechanics, as well as data for validation of these models. Numerical simulations offer enormous potential to the study of traumatic brain injury: TBI) and may also contribute to the development of prophylactic devices for high-risk subjects: …

    wustl Repository record for Magnetic Resonance Elastography of the Brain: from Phantom to Mouse to Man (opens in a new tab)

  6. Biomechanical characterization of video-recorded short-distance falls involving children equipped with a biometric device: a pilot study.

    … with a biometric measuring device that collected head accelerations and velocities during falls. Additionally, Head Injury Criteria (HIC) values and impact durations were determined. Video surveillance was used to capture fall dynamics and to provide reliable witnessed falls. For each fall event, …

    louisville Repository record for Biomechanical characterization of video-recorded short-distance falls involving children equipped with a biometric device: a pilot study. (opens in a new tab)

  7. Biomechanical Characterization of Video-Recorded Short-Distance Falls Involving Children Equipped with a Biometric Device in a Childcare Setting: A Pilot Study.

    … these short distance falls, to characterize the head biomechanics of these falls, and describe fall characteristics. Additionally, physics-based models were used to predict fall biomechanics in a subset of these falls. Methods: This study included children aged 12-25 months. Two childcare …

    louisville Repository record for Biomechanical Characterization of Video-Recorded Short-Distance Falls Involving Children Equipped with a Biometric Device in a Childcare Setting: A Pilot Study. (opens in a new tab)

  8. Assessment of head injury risk caused by impact using finite element models

    [ES] Las cargas de impacto son la fuente primaria de lesiones en la cabeza y pueden resultar en un rango de traumatismo desde leve hasta severo. Debido a la existencia de múltiples entornos en los que se pueden desencadenar lesiones por impacto (accidentes automovilísticos, deportes, caídas …

    upv Repository record for Assessment of head injury risk caused by impact using finite element models (opens in a new tab)

  9. CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF OPTIC NERVE HEAD IN RESPONSE TO INTRAOCULAR PRESSURE

    Optic nerve head tissue biomechanics may play a part in the development of glaucoma. This project aims to demonstrate the feasibility of estimating the ONH tissue stiffness in human eyes based on the ocular pulse-induced full-field deformations. This project can be divided into two parts: (1) the …

    nus Repository record for CHARACTERIZATION OF THE BIOMECHANICAL PROPERTIES OF OPTIC NERVE HEAD IN RESPONSE TO INTRAOCULAR PRESSURE (opens in a new tab)

  10. Block-Based Finite Element Head Modelling for High-Fidelity Strain Prediction and Multi-Resolution Traumatic Brain Injury Analysis

    Finite element (FE) head models enable estimation of full-field brain deformation. The predictive performance of these models is governed by interdependent factors such as mesh topology, element formulation, material constitutive law, and strain output interpretation. This thesis systematically …

    uwo Repository record for Block-Based Finite Element Head Modelling for High-Fidelity Strain Prediction and Multi-Resolution Traumatic Brain Injury Analysis (opens in a new tab)

  11. Biomechanical Investigation of Head Kinematics and Skull Stiffness

    This thesis presents two studies related to head injury. The study presented in Chapter 1 reviewed findings of cranial movement in animal and human specimens and evaluate the validity of cranial movement due to manual manipulation in humans through engineering analysis. The study had two parts. In …

    vt Repository record for Biomechanical Investigation of Head Kinematics and Skull Stiffness (opens in a new tab)

  12. Effects of Scleral Stiffness on Biomechanics of the Optic Nerve Head in Glaucoma

    … within the tissues of the optic nerve head (ONH), and that the altered biomechanical environment contributes to optic nerve damage and consequent loss of vision. The biomechanical environment of the ONH is strongly dependent on the biomechanical properties of sclera, particularly …

    toronto-retro Repository record for Effects of Scleral Stiffness on Biomechanics of the Optic Nerve Head in Glaucoma (opens in a new tab)