Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Head Discharge"”.

  1. Piano Key Weir Head Discharge Relationships

    … and a limited understanding of their effects on discharge efficiency (discharge efficiency is quantified by the discharge coefficient of the standard weir equation). However, Hydrocoop, a non-profit French dam spillways association, has recommended a PK weir design and a head-discharge …

    utahstate Repository record for Piano Key Weir Head Discharge Relationships (opens in a new tab)

  2. Calibration and uncertainty of a head-discharge relationship for overshot gates under field conditions

    … gates (pivot weirs) are commonly used to control discharge and water levels in irrigation water delivery networks. The degree to which this control can be achieved depends upon reliable relationships between flow rate and the hydraulic head upstream and downstream of the gate. Moreover, such …

    colostate Repository record for Calibration and uncertainty of a head-discharge relationship for overshot gates under field conditions (opens in a new tab)

  3. Size Scale Effects on Linear Weir Hydraulics

    … of weirs that is particularly useful is the head-discharge relationship where the discharge over the weir is directly related to the upstream water depth above the crest. In general, the head-discharge relationship for a weir is determined experimentally using geometrically similar models. …

    utahstate Repository record for Size Scale Effects on Linear Weir Hydraulics (opens in a new tab)

  4. Nonlinear Weir Hydraulics

    … the weir crest elevation, and can influence the head-discharge relationship of the structure. The effects of tailwater submergence on laboratory-scale piano key weir head-discharge relationships were evaluated experimentally and compared to previously published data on linear and labyrinth weir …

    utahstate Repository record for Nonlinear Weir Hydraulics (opens in a new tab)

  5. Hydraulic Performance of Porous Sediment Control Structures

    … efficiency are studied in this research. The head-discharge relationship for filter fabric has been developed by first applying the Bernoulli equation to a single opening and then extending the principle to the entire cross-sectional area. An opening coefficient, which varies with hydraulic …

    uiuc Repository record for Hydraulic Performance of Porous Sediment Control Structures (opens in a new tab)

  6. Hydraulic interaction between the above and below ground drainage systems via gully inlets

    … from typical gully systems by determining the head-discharge relationship of each system. Therefore, a full scale laboratory system comprising of a testing platform with an inlet tank and an outlet tank on both ends of the platform has been designed to mimic the hydraulic interaction between …

    whiterose Download PDF for Hydraulic interaction between the above and below ground drainage systems via gully inlets (opens in a new tab)

  7. Effects of bridge deck submergence on backwater

    … systems. Such curves provide a specific head discharge relationship that can then be non-dimensionalized using Froude scaling for greater applicability. An additional set of physical experiments will be conducted to analyze the effects of tailwater elevation and submergence (of the bridge …

    texas Repository record for Effects of bridge deck submergence on backwater (opens in a new tab) Restricted access

  8. A sequential inverse approach for hydraulic tomography and electrical resistivity tomography: An effective method for site characterization

    … of an aquifer, conditioned on each set of head/discharge data. To efficiently include all the head/discharge data sets, a sequential conditioning method is employed. Two-dimensional numerical experiments were conducted to investigate the optimal sampling scheme for the hydraulic tomography. …

    arizona-thes Repository record for A sequential inverse approach for hydraulic tomography and electrical resistivity tomography: An effective method for site characterization (opens in a new tab)

  9. Hydraulics of IDEal Drip Irrigation Systems

    … based on the wall thickness and inlet pressure head. The equivalent length barb loss, expressed as an equivalent length of lateral, was calculated for button emitters, as well as for micro-tubes inserted to lengths of 5 and 10 cm. It was concluded that the barb loss is essentially constant over …

    utahstate Repository record for Hydraulics of IDEal Drip Irrigation Systems (opens in a new tab)

  10. Submerged and Floating Woody Debris-Blocking Sensitivity of Labyrinth Weirs

    … at flow control structures can result in reduced discharge efficiency (higher upstream head for a given weir discharge). Labyrinth weirs are more prone to debris blockage than less efficient control structures due to their ability to pass large amounts of flow with relatively small heads. …

    utahstate Repository record for Submerged and Floating Woody Debris-Blocking Sensitivity of Labyrinth Weirs (opens in a new tab)

  11. Fluid Structure Interaction of a Duckbill Valve

    … valve as the upstream pressure increases. The head-discharge behavior is a fluid-structure interaction (FSI) problem since the discharge depends on the valve opening that in turn depends on the pressure distribution along the valve produced by the discharge. To design a duckbill valve, a …

    mcmaster Repository record for Fluid Structure Interaction of a Duckbill Valve (opens in a new tab)

  12. Reservoir Applications of Arced Labyrinth Weirs

    … are now deficient as they do not meet current discharge capacity requirements. To rehabilitate existing, fixed-width spillways, labyrinth weirs are often viable solutions. For reservoir applications, arcing labyrinth weirs into the reservoir increases hydraulic efficiency. This results from …

    utahstate Repository record for Reservoir Applications of Arced Labyrinth Weirs (opens in a new tab)

  13. Size-Scale Effects of Nonlinear Weir Hydraulics

    … However, as model size and/or upstream head decreases, other fluid forces can exceed the negligible level and influence model flow behavior. This phenomenon is referred to as size-scale effects and is one potential origin of error in predicting the prototype behavior through testing …

    utahstate Repository record for Size-Scale Effects of Nonlinear Weir Hydraulics (opens in a new tab)

  14. THE HYDRAULIC PERFORMANCE OF PERFORATED PIPE UNDER-DRAINS SURROUNDED BY LOOSE AGGREGATE

    … of water above the pipe, and the resulting discharge for a trench filled with aggregate that is fed with water from one end. The pipes tested were leached and perforated, for both 10.2 cm and 15.2 cm diameters. The pipes were tested for three different trench widths filled with 28 cm of #57 …

    clemson Repository record for THE HYDRAULIC PERFORMANCE OF PERFORATED PIPE UNDER-DRAINS SURROUNDED BY LOOSE AGGREGATE (opens in a new tab)

  15. Air Demand in Low-Level Outlet Works

    … feature a vertical gate in a flat-bottomed discharge tunnel. The large-dam air demand analysis has been based on the Froude number of the supercritical flow at the vena contract (located between the gate and the hydraulic jump) and the water flow rate. Small to medium-sized embankment dams …

    utahstate Repository record for Air Demand in Low-Level Outlet Works (opens in a new tab)

  16. Flow Characteristics of Arced Labyrinth Weirs

    The need to accommodate larger reservoir discharge events has prompted the improvement or replacement of existing spillways. One possible spillway modification is the use of an in-reservoir arced labyrinth weir in place of a linear weir. Arced labyrinth weirs can increase crest length (more cycles) …

    utahstate Repository record for Flow Characteristics of Arced Labyrinth Weirs (opens in a new tab)

  17. Air Vent Sizing in Low-Level Outlet Works for Small- to Medium-Sized Dams

    … to a vertical slide gate that is followed by a discharge tunnel. The typical air vent design for these large dams uses the water flow rate and the Froude number measured at the vena contracta downstream of the gate. The low-level outlet works for small-to-medium-sized embankment dam geometries …

    utahstate Repository record for Air Vent Sizing in Low-Level Outlet Works for Small- to Medium-Sized Dams (opens in a new tab)

  18. Laboratory measurements and computer simulations of highly curved flow after sluice gate

    … widely used for such purposes as the control of discharges and water levels in hydraulic engineering systems. It is important to understand the features of turbulent flow passing underneath a sluice-gate. Previously, a great deal of research attention has centred on such flow features as the …

    concordia Download PDF for Laboratory measurements and computer simulations of highly curved flow after sluice gate (opens in a new tab)

  19. Optimizing the performance of a spiral water wheel pump

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2023-04-12 without embargo terms

    uiuc Repository record for Optimizing the performance of a spiral water wheel pump (opens in a new tab)