Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"Head coil"”

  1. Solution of coupled acoustic eigenvalue problems

    … of this thesis. The confined space inside the head coil of the MRI machine creates an acoustic environment where mixed modes appear. That is, standing waves that oscillate both inside the oral cavity and the head coil are formed. Hence, it is important that the acoustic environment consisting …

    aalto Repository record for Solution of coupled acoustic eigenvalue problems (opens in a new tab)

  2. PROSPECTIVE HEAD MOVEMENT CORRECTION FOR HIGH-RESOLUTION MRI USING AN IN-BORE OPTICAL TRACKING SYSTEM

    … degradation. To compensate the effects of head motion during data acquisition, an in-bore optical motion tracking system is proposed. The system comprises one or two MR compatible infrared cameras that are fixed on a holder right above and in front of the head coil. The resulting close …

    maryland Repository record for PROSPECTIVE HEAD MOVEMENT CORRECTION FOR HIGH-RESOLUTION MRI USING AN IN-BORE OPTICAL TRACKING SYSTEM (opens in a new tab)

  3. RF and electronic design perspective on ultra-high field MRI systems

    … the fully automatic matched / tuned RF head coil design and RF coil design with improved B1 field uniformity. Both have been being considered as critical problems at ultra-high field (7T and beyond) MRI systems. The first study aims to build a real-time, high-speed, electrically …

    umn Repository record for RF and electronic design perspective on ultra-high field MRI systems (opens in a new tab)

  4. NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS

    In this dissertation new designs for gradient coils are presented. The principal work is on better shielding for fringe field reduction. Fringe fields from gradient coils produce eddy currents in surrounding metal structures. Such eddy currents can degrade image quality and lead to acoustic noise. …

    ohiolink Repository record for NEW DIRECTIONS IN THE DESIGN OF MRI GRADIENT COILS (opens in a new tab)

  5. The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging

    … this dissertation, a novel RF coil design, termed the wireless integrated parallel reception, excitation, and shimming (iPRES-W) coil design, is further developed to remove some of these wired connections by offering a compact and easy-to-integrate MR-compatible wireless data …

    duke Repository record for The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging (opens in a new tab)

  6. Investigation of brain tissue water NMR response by optimised quantitative single-voxel proton magnetic resonance spectroscopy

    … RF field within an eight-channel head coil; 2) measurement of the relaxation times of brain tissue water using standard saturation recovery and multi spin-echo MRS techniques; 3) measurement of brain tissue water content in peripheral inflammation; and 4) estimation of the BOLD …

    glasgow Repository record for Investigation of brain tissue water NMR response by optimised quantitative single-voxel proton magnetic resonance spectroscopy (opens in a new tab)

  7. Magnetic resonance imaging to improve structural localisation in radiotherapy planning

    … mask can be problematic, since the multi-channel head coils typically used in diagnostic imaging, are not compatible with the immobilisation mask. To assess the image quality which can be obtained with MR imaging in the RT position, various MRI quality assurance phantoms were positioned within an …

    glasgow Repository record for Magnetic resonance imaging to improve structural localisation in radiotherapy planning (opens in a new tab)

  8. Assessing Multi-Coil Deep-learning-based MR Image Reconstruction

    … parallel imaging uses an array of receiver coils to reduce the amount of data acquired. Recently deep learning (DL)-based MR image reconstruction has become popular as it allows for further scan acceleration. With its advent, new questions are raised regarding optimal coil design and …

    calgary Repository record for Assessing Multi-Coil Deep-learning-based MR Image Reconstruction (opens in a new tab)

  9. Methods and adaptations required to perform small-animal MRI scanning using a large bore clinical MRI

    … of a small-animal radiofrequency (RF) coil, physical support (cradle), a core body temperature regulation system, and optimization of pulse sequences. The system was validated using a phantom and in-vivo in 5 healthy rats. The signal-to-noise ratio (SNR) in the phantom was 91% higher …

    cape-town Repository record for Methods and adaptations required to perform small-animal MRI scanning using a large bore clinical MRI (opens in a new tab)

  10. Three Studies in High-Field MR Engineering: SAR Reduction Through Sequential RF Pulses, A System for B1+ Steering, and A Low-Complexity Multi-Nuclei Array Coil

    … rate (SAR) also come with the UHF scanner. A head coil array at 9.4T using a novel transmit approach of serial transit parallel receive (STxPRx) is modeled and analyzed in this doctoral work. By transmitting each coil element in an array sequentially rather than simultaneously, a 25.7% peak …

    tamu Repository record for Three Studies in High-Field MR Engineering: SAR Reduction Through Sequential RF Pulses, A System for B1+ Steering, and A Low-Complexity Multi-Nuclei Array Coil (opens in a new tab)

  11. Neurometabolites in anterior cingulate cortex in chronic fatigue syndrome: A magnetic resonance spectroscopy study at 7 Tesla

    … with a Nova Medical 32 channel receive array head coil. Spectra were measured from voxels in the ACC (20 × 20 × 20 mm), putamen (10 × 16 × 20 mm) and occipital cortex (20 × 20 × 20 mm). Spectra were analysed with LCModel to obtain absolute concentrations of the neurochemicals. Differences in …

    oxford Repository record for Neurometabolites in anterior cingulate cortex in chronic fatigue syndrome: A magnetic resonance spectroscopy study at 7 Tesla (opens in a new tab)

  12. Magnetic resonance imaging and anthropometric measurements: a correlational study in fixed fetal specimens

    … acquired using the 8-channel high-resolution head coil made by Invivo for the Achieva 3T scanner. This study found that the measurements taken from the images, and the feet had good intra-rater reliability because paired t-tests did not show significant differences between the measurements …

    bu Repository record for Magnetic resonance imaging and anthropometric measurements: a correlational study in fixed fetal specimens (opens in a new tab)

  13. Parallel transmit pulse sequence design for ultra-high field (7T) MRI

    … of the vendor-provided single transmission head coil against its pTx counterpart (Chapter 5). Image quality is comparable for both coils, with the pTx coil showing significant increases in B+1 values (between 4.9 – 18.9%) in the caudate, insula, putamen, and temporal lobes. This translates …

    cambridge Repository record for Parallel transmit pulse sequence design for ultra-high field (7T) MRI (opens in a new tab)

  14. Investigation of Metamaterial Transmission line resonators for Ultra-High Field Magnetic Resonance Imaging RF Coils

    The objective is to develop a highly efficient RF head coil on a thin substrate for the Ultra-high magnetic field (7 T and above) MRI systems. The artificial Metamaterial resonator is investigated for this purpose. Simulation and experimental results are provided for an 8-channel Metamaterial based …

    umn Repository record for Investigation of Metamaterial Transmission line resonators for Ultra-High Field Magnetic Resonance Imaging RF Coils (opens in a new tab)

  15. Assessment of Pseudo-Continuous Arterial Spin Labeling (pCASL) Inter-Session Reliability in the Quantification of Cerebral Perfusion

    … conducted on a 3T MRI scanner with a 24-channel head coil. Each of the iv three days began with a baseline imaging scan followed by sham transcranial direct current stimulation (tDCS) and another identical imaging session. MRI acquisition included a 12-min resting-state function MRI (fMRI), three …

    ohiolink Repository record for Assessment of Pseudo-Continuous Arterial Spin Labeling (pCASL) Inter-Session Reliability in the Quantification of Cerebral Perfusion (opens in a new tab)

  16. Strukturelle Analyse des Alterungsprozesses im menschlichen Innenohr mittels Magnetresonanztomographie

    … correlation between TIV, as a surrogate for head size, and the majority of inner ear parameters. The vestibulocochlear nerve and facial nerve showed a significant increase in length with age, with a simultaneous increase in the craniocaudal distance between the level of the nerve origin at …

    lmu-germany Repository record for Strukturelle Analyse des Alterungsprozesses im menschlichen Innenohr mittels Magnetresonanztomographie (opens in a new tab)

  17. Analysis of Noise Power Spectra in MR Parallel Imaging

    … Premier 3.0 T MR scanner alongwith a 48-channel head coil to obtain several volumetric images of a vendor QC headphantom to obtain a total of 17 different sets of images using three different pulsesequences: spin echo, fast spin echo, and gradient echo. Parallel imaging withacceleration factors …

    ohiolink Repository record for Analysis of Noise Power Spectra in MR Parallel Imaging (opens in a new tab)

  18. Slice-selective parallel transmit magnetic resonance imaging at 7T

    … of how novel pulse designs like BOGAT and coils with full virtual observation point (VOP) supervision can alleviate these challenges. Additionally, it demonstrates the practical challenges of implementing pTx in clinical settings. The new BOGAT and spokes SBB developments are exemplified in …

    cambridge Repository record for Slice-selective parallel transmit magnetic resonance imaging at 7T (opens in a new tab)

  19. Large-scale Modelling of Patient Motion for Head Coils at 7T Using Magnetic Resonance Integral Equations

    … body. Instead of individually simulating each coil, this method uses matrices precomputed during an offline phase to evaluate fields from various coil designs with the same body model very quickly during the online phase. By employing integral equation solvers, the fields are produced for each …

    kings Repository record for Large-scale Modelling of Patient Motion for Head Coils at 7T Using Magnetic Resonance Integral Equations (opens in a new tab)

  20. Dynamic magnetic field estimation for magnetic resonance imaging

    … camera integrated into a 95 channel receive head coil array. This combined coil and field camera was used for very fast 3D functional magnetic resonance imaging experiments. Small effects, such as a shift along the z-axis of the reconstructed slices and reduced signal loss were corrected for …

    freiburg-diss Repository record for Dynamic magnetic field estimation for magnetic resonance imaging (opens in a new tab)

Page 1 of 2