Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"Headed bars"”.

  1. Static and Fatigue Behaviour of Hybrid FRP-Concrete Bridge Truss Girder with Connections Reinforced with Double-Headed Bars

    An innovative hybrid FRP-concrete bridge system for short- and medium-span bridges has been developed at the University of Calgary. This system is composed of concrete deck slabs composite with precast prestressed concrete truss girders, consisting of pre-tensioned top and bottom chords connected …

    calgary Repository record for Static and Fatigue Behaviour of Hybrid FRP-Concrete Bridge Truss Girder with Connections Reinforced with Double-Headed Bars (opens in a new tab)

  2. Static and Fatigue Behaviour of Hybrid Precast Concrete Truss Bridge Girders with Connections Reinforced with Single-Headed Bars

    The structural performance of a novel hybrid precast concrete truss bridge girder proposed by Elbadry (2002) is experimentally investigated in this research. This new corrosion-resistant structural system benefits from the best characteristics of both fibre reinforced polymers (FRPs) and concrete …

    calgary Repository record for Static and Fatigue Behaviour of Hybrid Precast Concrete Truss Bridge Girders with Connections Reinforced with Single-Headed Bars (opens in a new tab)

  3. Anchorage of Headed Reinforcing Bars in Exterior Beam-Column Joints

    In reinforced concrete members, headed bars are often used to anchor reinforcing steel when member geometry is insufficient for the full development of straight bars; the shorter development lengths and compact size also reduce congestion. Currently, very limited research has been performed on the …

    ku Repository record for Anchorage of Headed Reinforcing Bars in Exterior Beam-Column Joints (opens in a new tab)

  4. DEVELOPMENT OF LARGE HIGH-STRENGTH REINFORCING BARS WITH STANDARD HOOKS AND HEADS

    Hooked and headed reinforcing bars are viable alternatives for development of reinforcing steel when member geometry does not allow for a straight deformed bar to fully develop its yield strength. Current design provisions in ACI 318-19 Building Code impose limitations on the use of hooked and …

    ku Repository record for DEVELOPMENT OF LARGE HIGH-STRENGTH REINFORCING BARS WITH STANDARD HOOKS AND HEADS (opens in a new tab)

  5. ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE

    Headed reinforcing bars serve as a viable alternative to hooked bars for anchorage in concrete because they provide a more efficient anchorage mechanism and limit congestion of the reinforcement. This study is part of a comprehensive study of the anchorage behavior of the headed bars. The work …

    ku Repository record for ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE (opens in a new tab)

  6. ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS IN CONCRETE

    Hooked and headed reinforcing bars are commonly used as a means of shortening development length of reinforcing bars, but a limited amount of previous research has resulted in restrictions on their use in practice. This study included two phases: In the first phase, 31 tests of simulated …

    ku Repository record for ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS IN CONCRETE (opens in a new tab)

  7. Numerical and experimental investigations of nonlinear behavior of RC members and slab-column assemblies in bridges

    … and the bond-slip behavior of reinforcing bars embedded in concrete have been identified and calibrated, and a constitutive model that accounts for the low-cycle fatigue behavior of steel has been developed and implemented in a finite element analysis program.In the first study, the impact …

    greece Repository record for Numerical and experimental investigations of nonlinear behavior of RC members and slab-column assemblies in bridges (opens in a new tab)

  8. Behavior and modeling of bent-to-column connections subjected to lateral loads

    … is not provided to the column’s longitudinal bars anchoring into the bent cap. However, lateral loads, such as vehicle collisions or stream loads, may produce moment transfer between the bent cap and the column. This study focuses on studying the behavior of the bent-to-column connections, …

    texas Repository record for Behavior and modeling of bent-to-column connections subjected to lateral loads (opens in a new tab)

  9. Compression Lap Splices of Straight Bars and Compression Development of Headed and Hooked Bars in Beam-Column Joints

    … provisions for compression lap splices and for headed and hooked bar development in special moment frame (SMF) joints were evaluated against databases of test results. Recommendations are made for simplifying and improving code requirements.Compression lap splice length provisions (ACI 318-19 …

    ku Repository record for Compression Lap Splices of Straight Bars and Compression Development of Headed and Hooked Bars in Beam-Column Joints (opens in a new tab)

  10. Behaviour of Concrete Beam-Column Joints Reinforced with Steel or Glass Fibre-Reinforced Polymer Double-Headed Studs for Seismic Resistance

    … reinforcing the beam-column joints. Use of the headed studs in the joint results in reduction of the steel congestion, and hence, easier assemblage of the reinforcing cage and improved joint performance. The present research investigates experimentally the use of steel double-headed studs with …

    calgary Repository record for Behaviour of Concrete Beam-Column Joints Reinforced with Steel or Glass Fibre-Reinforced Polymer Double-Headed Studs for Seismic Resistance (opens in a new tab)

  11. GFRP-reinforced concrete exterior beam-column joints subjected to seismic loading

    … inside the joint (using either bent bars or headed bars) and to evaluate the shear capacity of the joint. In the analytical phase, a commercial FEM software (ATENA-3D) was used to run a parametric study that investigated the influence of the presence of lateral beams, axial load on …

    manitoba Repository record for GFRP-reinforced concrete exterior beam-column joints subjected to seismic loading (opens in a new tab)

  12. 3D strut-and-tie design recommendations for column and drilled shaft anchorages in drilled shaft footings

    … different column bar anchorage details: straight bars, hooked bars with two different hook orientations, and headed bars. All column reinforcement in Phase II specimens could yield during the tests regardless of the anchorage types. Furthermore, all anchorage types developed reinforcing bar …

    texas Repository record for 3D strut-and-tie design recommendations for column and drilled shaft anchorages in drilled shaft footings (opens in a new tab)

  13. EXPERIMENTAL ANALYSIS FOR STEEL CONGESTION RELIEF IN CONCRETE STRUCTURES UNDER MONOTONIC AND SEISMIC LOADS

    … congestion was effectively reduced by the use of headed bars instead of traditional hooked bars. This first and third approach is emerging as a research topic of special interest in the American Concrete Institute (ACI).

    oklahoma-thes Repository record for EXPERIMENTAL ANALYSIS FOR STEEL CONGESTION RELIEF IN CONCRETE STRUCTURES UNDER MONOTONIC AND SEISMIC LOADS (opens in a new tab)

  14. Static and Fatigue Behaviour of Concrete Truss Girder Connection Reinforced with Double-Headed Glass FRP Bars

    … truss girder connections reinforced with double-headed GFRP bars. For this application the efficiency of the anchoring heads of the individual double-headed GFRP bars under static and fatigue loading needs to be tested first. Therefore, a total of eighteen specimens of individual double-headed …

    calgary Repository record for Static and Fatigue Behaviour of Concrete Truss Girder Connection Reinforced with Double-Headed Glass FRP Bars (opens in a new tab)

  15. Experimental and analytical investigation of the out-of-plane behavior of bridge bent-to-column connections

    … anchorage by comparing standard straight bars with headed bars. Experimental results demonstrated that all specimens successfully developed their full flexural capacity, with longitudinal reinforcement reaching yield levels. The PC specimens showed enhanced peak capacities and sustained …

    texas Repository record for Experimental and analytical investigation of the out-of-plane behavior of bridge bent-to-column connections (opens in a new tab)

  16. Investigation of Glass Fibre Reinforced Polymer (GFRP) Bars as Internal Reinforcement for Concrete Structures

    … Reinforced Polymer (GFRP) internal reinforcing bars are being increasingly considered as a potential corrosion free alternative to regular and stainless steel reinforcing bars. In spite of the availability of code provisions governing both design and certification of the GFRP bars, their use …

    toronto-retro Repository record for Investigation of Glass Fibre Reinforced Polymer (GFRP) Bars as Internal Reinforcement for Concrete Structures (opens in a new tab)

  17. Experimental Investigation of Reinforced Concrete Beams with Lapped Reinforcement

    … were tested in this project. One type was a headed bar reinforcement which was tested in various spacing and lap lengths. The second type of joint was welded wire reinforcement with varying wire spacing. In order to accelerate bridge construction, it is desirable to narrow the width of the …

    ut-knoxville Repository record for Experimental Investigation of Reinforced Concrete Beams with Lapped Reinforcement (opens in a new tab)

  18. Experimental and analytical investigations on bond of reinforcement and nonlinear response of reinforced concrete columns

    … of iron-based shape-memory alloy (Fe-SMA) bars. Fe-SMA reinforcement provides new opportunities for design and strengthening of concrete structures thanks to their shape memory effect. However, there is currently little data on its bond performance. Experiments were conducted to study the …

    texas Repository record for Experimental and analytical investigations on bond of reinforcement and nonlinear response of reinforced concrete columns (opens in a new tab)

  19. Experimental and Analytical Studies of a Two-Span Bridge System with Precast Elements Incorporating Rebar Hinge and Socket Connections

    … beam connection. (3) extended strands and headed bars enclosed in the cast-in-place portion of the cap beam for the girder-to-cap beam connection, (4) lap spliced straight bars embedded in ultra-high performance concrete (UHPC) for the deck connection over the pier, (5) precast deck panels …

    unr Repository record for Experimental and Analytical Studies of a Two-Span Bridge System with Precast Elements Incorporating Rebar Hinge and Socket Connections (opens in a new tab)

  20. Behaviour of corbels reinforced with headed-end GFRP bars

    … life. Glass fibre-reinforced polymer (GFRP) bars have electromagnetically inert properties, which alleviate long-term durability concerns due to corrosion. Extensive research over the past two decades have proven that the use of GFRP bars in new structures is desirable to extend the service …

    manitoba Repository record for Behaviour of corbels reinforced with headed-end GFRP bars (opens in a new tab)