Showing 1 to 20 of 28 for “"Hearing Protectors"”.
-
Hearing protectors: a dilemma involving acoustics and personal safety
This thesis is concerned with the optimising of hearing protector selection. A computer model was used to estimate the reduction in noise exposure and risk of occupational deafness provided by the wearing of hearing protectors in industrial noise spectra. The model was used to show that low …
-
Physical method for the field measurement of the attenuation of muff-type hearing protectors, A
Includes bibliographical references.
-
Evaluation of Changes in Speech Production Induced by Conventional and Level-Dependent Hearing Protectors and Noise Characteristics
The use of personal hearing protection devices (HPDs) is often recommended to protect workers' hearing from noise-induced damage when no other means of reducing noise levels at the source is effective. The effects of HPDs on speech communication cannot be neglected in spite of their benefit in …
-
Spectral attenuation and wearability of circumaural hearing protectors as influenced by design attributes and work-related activity
Hearing protection devices (HPDs), a widely used countermeasure against noise-induced hearing loss, are laboratory-tested for their attenuation (noise reduction) capabilities. Unfortunately, laboratory tests overestimate the in-workplace performance of the devices, potentially leading to inadequate …
-
The effect of passive and electronic amplitude-sensitive hearing protectors on the detection of a warning signal
An experiment was conducted to study earmuff wearers’ signal detection in noise performance and perceptions of comfort and acceptability with two amplitude-sensitive earmuffs as compared to their conventional counterparts. Passive and electronic amplitude-sensitive earmuffs were tested, represented …
-
Instructional requirements for using the HML and NRR methods for estimating protected exposure levels under hearing protectors
… teaching individuals to calculate a protected hearing level given A- or C-weighted sound levels, and using the NRR and HML methods. Three instructional tools were evaluated: 1) outline instructions, 2) tabular nomogram, and 3) hypermedia computer-based instructions. Effectiveness was measured …
-
Laboratory investigation of in-field influences on spectral noise attenuation and comfort of insert and circumaural hearing protectors
Laboratory-obtained, manufacturer-supplied hearing protector attenuation ratings typically overestimate the workers' protection level In the workplace. In addition, several work-related in-field factors often degrade protection performance of the hearing protection devices (HPDs), posing the threat …
-
Investigation of physical and psychophysical methods for the attenuation measurement of circumaural hearing protectors with implication for field use
… the attenuation workers are achieving with their hearing protectors in the field. Alternative measures for assessing a hearing protector's effectiveness were evaluated through comparison to the standardized real-ear attenuation at threshold (REAT) method, termed 1I3-REAT, a psychophysical …
-
Field evaluation of noise attenuation and comfort performance of earplug, earmuff, and ear canal cap hearing protectors under the ANSI S12.6- 1984 sound field standard
… workplaces wearing 4 different industrial hearing protection devices (HPDs) while on the job. Over 2 consecutive 3-week periods of HPD use, the study investigated the effects of 2 different HPD fitting procedures (subject-fit versus trained-fit) on the spectral field attenuation and …
-
Azimuthal Localization and Detection of Vehicular Backup Alarms Under Electronic and Non-Electronic Hearing Protection Devices in Noisy and Quiet Environments
Objective assessment for the effect of hearing protectors, background noise levels, and backup alarm acoustic features on listeners' abilities to localize backup alarm signals in the horizontal dimension, as well as on their ability to detect backup alarm signals in the distance dimension, is …
-
Measuring hearing protection performance results in a MIRE-compliant reverberatory chamber versus a non-MIRE compliant room
… Agency (EPA) to determine the effectiveness of hearing protection devices (HPD). The limitations of NRR values have led to use of other methods, including fit-testing hearing protectors on the individuals who will use them. The fit-testing method used in this study is the Microphone in Real Ear …
-
The role of audiometry in the prevention of occupational deafness
… audiometry increases the probability that hearing protectors, once issued, will be worn; (2) audiometry is considered by workers to be evidence of their employer's concern for their welfare; (3) audiometry is associated with common law claims by workers against employers for alleged …
-
Noise exposure in steel stud construction: noise characterizations and tool limit guidance for commercial framers
… is well-demonstrated to be hazardous to hearing, with high rates among construction workers of occupational noise-induced hearing loss. This study focused on an under-studied population of construction workers: Commercial framers who cut and install steel studs as their primary task. This …
-
Barriers to occupational noise management
… of noise results in cumulative damage to the hearing mechanism of the ear and a subsequent hearing loss. This hearing loss is permanent and does not recover over time. Initially the conventional method of addressing or controlling noise exposure was through Hearing Conservation Programs and …
-
Gunshots Sound Analysis, Identification, and Impact on Hearing
… understanding of the impact of this sound on hearing. Exposure to gunshot sounds can cause hearing impairments. Measuring these sounds from various locations and analyzing them can improve the design of hearing protectors and help enact regulations to minimize the impact of gunshot sounds on …
-
Effects of anechoic vs. reverberant sound-field, subject gender, and outlier dismissal on the real-ear attenuation of hearing protection devices
… environment on the measured attenuation of hearing protection devices (HPDs) when using a standard real-ear attenuation at threshold (REAT) protocol. In the experiment, three earmuffs and three earplugs were tested in two diffuse sound fields implemented in two different sound environments …
-
Development of algorithms for smart hearing protection devices
In industrial environments, wearing hearing protection devices is required to protect the wearers from high noise levels and prevent hearing loss. In addition to their protection against excessive noise, hearing protectors block other types of signals, even if they are useful and convenient. …
-
Verificación de los niveles de atenuación de dos tipos de protectores auditivos tipo copa en trabajadores de una empresa del sector Hidrocarburos. Barrancabermeja-Colombia 2013.
… verifying the attenuation levels of two twin-cup hearing protectors under actual operation conditions of a hydrocarbons company in Colombia. This verification process was carried out by determining the existing differences between the attenuation levels established by the manufacturer (theoretical …
-
Low Frequency Modeling and Experimental Validation of Passive Noise Attenuation in Ear Defenders
… the dynamics that govern the attenuation of hearing protectors. This thesis duplicates some of this work with newer technology and better data processing ability. In addition to revitalizing the accepted knowledge of hearing protector technology, this thesis is the first documented effort to …
-
Experimental and numerical study on the contribution of acoustic test fixtures to hearing protector sound attenuation: Sound transmission paths in the case of a double hearing protector and influence of eardrum acoustic impedance
… be adopted to assess the sound attenuation of hearing protectors (e.g., earplugs and earmuffs) as they can facilitate measurements, and allow data acquisition under severe noise conditions. However, standardized ATFs are not realistic enough to closely capture the subjective attenuation of all …
Page 1 of 2