Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"Hearing levels"”.

  1. CO2-laserstapedotomy: analysis of used energy and its influence on bone- conduction hearing levels

    … used energy and post-operative bone conduction hearing thresholds to assess a possible laser-induced inner-ear damage. A prospective analysis of the influence of cumulative laser energy on post-operative bone conduction hearing thresholds was performed with data from 391 primary cases that were …

    fu-berlin Repository record for CO2-laserstapedotomy: analysis of used energy and its influence on bone- conduction hearing levels (opens in a new tab)

  2. Role of Driver Hearing in Commercial Motor Vehicle Operation: An Evaluation of the FHWA Hearing Requirement

    … commerce possess a certain minimal level of hearing. After an extensive literature review on topics related to hearing and driving, a human factors engineering approach was used to evaluate the appropriateness of this hearing requirement, the methods currently specified to test drivers' …

    vt Repository record for Role of Driver Hearing in Commercial Motor Vehicle Operation: An Evaluation of the FHWA Hearing Requirement (opens in a new tab)

  3. MICROSTRUCTURE AUDIOGRAMS AND PSYCHOPHYSICAL TUNING CURVES FROM SUBJECTS WITH SPONTANEOUS OTOACOUSTIC EMISSIONS (HEARING, ACOUSTICS).

    … been detected in 30 to 50% of individuals whose hearing is within normal limits. They are believed to originate in the cochlea but the mechanism by which they are produced remains unknown. It has not been determined if SOAEs are an indication of subtle abnormality in the cochlea or if they are …

    arizona-thes Repository record for MICROSTRUCTURE AUDIOGRAMS AND PSYCHOPHYSICAL TUNING CURVES FROM SUBJECTS WITH SPONTANEOUS OTOACOUSTIC EMISSIONS (HEARING, ACOUSTICS). (opens in a new tab)

  4. Psychophysical investigation of the real-ear attenuation of hearing protection devices under different sound-field diffusivity conditions

    … and international consensus standards governing hearing protection device (HPD) attenuation testing specify the use of a diffuse sound field to ensure the sound field remains uniform and random-incidence in an envelope about the subject’s head (ANSI, 1974; ANSI, 1984; British BSI 5108:1983; …

    vt Repository record for Psychophysical investigation of the real-ear attenuation of hearing protection devices under different sound-field diffusivity conditions (opens in a new tab)

  5. Comparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards development

    Federal law requires hearing protection device (HPD) manufacturers to provide attenuation ratings for use in estimating workers’ protection levels. These ratings, which are laboratory obtained, typically overestimate the actual protection levels achieved in the workplace. This research investigated …

    vt Repository record for Comparison of laboratory protocols for yielding improved estimates of hearing protection in field performance for use in standards development (opens in a new tab)

  6. Perceptual and electrophysiological masking of the auditory brainstem response : a thesis presented in partial fulfilment of the requirements for the degree of Master of Arts in Psychology at Massey University

    Effective masking levels of the auditory brainstem response (ABR) to tonepips were established on 10 normal-hearing subjects at 500, 1000, 2000 and 4000 Hz, using white noise. Effective masking levels of perceptual responses to the same stimuli were also established, for both presentation of single …

    massey Repository record for Perceptual and electrophysiological masking of the auditory brainstem response : a thesis presented in partial fulfilment of the requirements for the degree of Master of Arts in Psychology at Massey University (opens in a new tab)

  7. The effect of passive and electronic amplitude-sensitive hearing protectors on the detection of a warning signal

    … via masked threshold determination in three levels of pink noise (75, 85, and 95 dBA), using a digitized back-up alarm as the detection stimulus. A modified Hughson-Westlake procedure was used to obtain 10 trials for each earmuff under each noise level. Comfort and acceptability were …

    vt Repository record for The effect of passive and electronic amplitude-sensitive hearing protectors on the detection of a warning signal (opens in a new tab)

  8. Effects of anechoic vs. reverberant sound-field, subject gender, and outlier dismissal on the real-ear attenuation of hearing protection devices

    … environment on the measured attenuation of hearing protection devices (HPDs) when using a standard real-ear attenuation at threshold (REAT) protocol. In the experiment, three earmuffs and three earplugs were tested in two diffuse sound fields implemented in two different sound environments …

    vt Repository record for Effects of anechoic vs. reverberant sound-field, subject gender, and outlier dismissal on the real-ear attenuation of hearing protection devices (opens in a new tab)

  9. Suprasegmental patterns and word intelligibility of hearing-impaired children trained with the Verbo-tonal method

    … evaluate the suprasegmental patterns of fourteen hearing-impaired children, who were at different levels of training in the Verbo-tonal method. The Test of Rhythm and Intonation Patterns (TRIP) consisted of 25 prerecorded items with the nonsense syllable /ma/ repeated with variations in rhythm, …

    ut-knoxville Repository record for Suprasegmental patterns and word intelligibility of hearing-impaired children trained with the Verbo-tonal method (opens in a new tab)

  10. Factors Related to Hearing Aid Use among Older Adults from Hispanic/Latino Backgrounds: Findings from the Hispanic Community Health Study/Study of Latinos

    … of this dissertation was to understand perceived hearing loss and hearing health care use among older adults from Hispanic/Latino backgrounds using the Andersen model of health care utilization as a framework. A cross sectional analysis of audiometric and survey data from the Hispanic Community …

    usf Repository record for Factors Related to Hearing Aid Use among Older Adults from Hispanic/Latino Backgrounds: Findings from the Hispanic Community Health Study/Study of Latinos (opens in a new tab)

  11. Noise Exposure in Medical Helicopter Flights

    … area and personal samples, determining noise levels inside the helmet, and evaluating the current selection of personal protective equipment (PPE). Measurements gathered during personal sampling were statistically analyzed and calculated using OSHA 1910.95 App A to determine dose, reference …

    usf Repository record for Noise Exposure in Medical Helicopter Flights (opens in a new tab)

  12. Waking Effectiveness of Emergency Alerting Devices for the Hearing Able, Hard of Hearing, and Deaf Populations

    … alerting devices. Three groups of varying hearing levels were tested: hearing able, hard of hearing, and deaf. The devices evaluated are a typical audible smoke detector, a strobe light, and a bed shaker. The subjects were monitored for sleep stage during the single night tests and the …

    maryland Repository record for Waking Effectiveness of Emergency Alerting Devices for the Hearing Able, Hard of Hearing, and Deaf Populations (opens in a new tab)

  13. Using signal detection theory to model the detection of warning signals in normal and hearing-impaired listeners while wearing hearing protection

    … of whether or not an individual suffering from a hearing loss is capable of hearing an auditory alarm or warning is an extremely important industrial safety issue. International standard ISO 773 1—1986(E), Danger Signals for Work Places — Auditory Danger Signals, requires that any auditory alarm …

    vt Repository record for Using signal detection theory to model the detection of warning signals in normal and hearing-impaired listeners while wearing hearing protection (opens in a new tab)

  14. The Clinical Application and Practical Limitations of Bone Conducted Speech

    … speech discrimination skills of ten normal hearing subjects, 21 to 30 years of age, on standard clinical equipment. Both the hearing levels (dB HL) and the sensation levels (dB SL) of the test administration were considered. In general, it was recommended that 100 dB Hl is the most …

    portland-state Repository record for The Clinical Application and Practical Limitations of Bone Conducted Speech (opens in a new tab)

  15. Assessment of Hearing Sensitivity by Use of the Acoustic Reflex in the Geriatric Population

    … to thirty years of age, with normal audiometric hearing levels served as controls. Reflex threshold levels were obtained using 500 Hz., 1000 Hz., and 2000 Hz. pure tones and noise stimuli. Assessment of hearing loss was calculated on the difference between measures to ascertain hearing loss …

    portland-state Repository record for Assessment of Hearing Sensitivity by Use of the Acoustic Reflex in the Geriatric Population (opens in a new tab)

  16. The Effect of Personal Listening Devices on Subjective Hearing Status

    … noise can trigger the onset of noise-induced hearing loss which can lead to a temporary (TTS) or permanent (PTS) shift in hearing threshold. Occupational noise, or recreational noise such as music can contribute to shifts in hearing levels. Listening to music in person at a concert or when …

    cuny-grad Repository record for The Effect of Personal Listening Devices on Subjective Hearing Status (opens in a new tab)

  17. Electromyographic Measurement of the Chinchilla Middle Ear Muscle Reflex Elicited by Acoustic or Blast Stimuli

    Hearing damage is a widespread problem that can cause social isolation and reductions in quality of life. A wide range of conditions including extended exposure to noise or near-instantaneous exposure to blast overpressure can result in hearing damage. When the ear is exposed to potentially …

    oklahoma-thes Repository record for Electromyographic Measurement of the Chinchilla Middle Ear Muscle Reflex Elicited by Acoustic or Blast Stimuli (opens in a new tab)

Page 1 of 3