Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Heart motion"”.
-
Development of a Heart Motion Tracking System using Non-invasive Imaging Data
Cardiac motion can be monitored non-invasively for the assessment of cardiovascular function by using medical imaging systems and motion tracking algorithms. Existing tracking approaches require a priori understanding of the non-rigid motion of the target system, which could change over multiple …
-
On the development of a heart motion compensation system on the da Vinci research kit for minimally invasive surgery on the beating heart
This thesis describes the development of a heart motion compensation system on the da Vinci Research Kit for coronary artery bypass surgery. With this teleoperation robotic platform, minimally invasive surgery on a beating heart could be performed on an already clinically prevalent system. …
-
Motion Detection in Dynamic Cardiac Positron Emission Tomography Images
… is violated in the presence of patient motion and heart motion. This thesis discusses methods for motion detection in dynamic cardiac 82Rb PET images.First, we determined if positron-emitting fiducial markers can be used as surrogate markers for heart motion in dynamic PET images. …
-
Feasibility of microwave radar system for proton emission therapy control.
… or abdomen, it is important to monitor lung and heart motion, as these organs displace local tissues. Conventional methods used for measurement of a patient's vital signs become problematic because metal wires or leads of these systems interfere with the proton beam. Metal leads and wires deflect …
-
RESTORATION AND FUNCTIONAL ANALYSIS OF NUCLEAR MEDICINE IMAGES
… of a movie-like display of the beating human heart to detect wall motion abnormalities which might be related to impaired cardiac function. The present work is directed toward extracting more information from the heart motion study, and presenting it in a useful manner. A spatially adaptive …
-
Incorporating the Aortic Valve into Computational Fluid Dynamics Models using Phase-Contrast MRI and Valve Tracking
The American Heart Association states about 2% of the general population have a bicuspid aortic valve (BAV). BAVs exist in 80% of patients with aortic coarctation (CoA) and likely influences flow patterns that contribute to long-term morbidity post-surgically. BAV patients tend to have larger …
-
Motion estimation using radiofrequency scattering of a parallel transmit coil for cardiac magnetic resonance imaging at 7T
… too slow to capture a fast moving organ like the heart. Synchronisation of the acquisition to the heart motion is necessary to acquire an image over several consecutive heartbeats. The current gold-standard method for cardiac synchronisation is the electrocardiogram (ECG), which measures the …
-
Image deblurring for visualization of coronary microcirculation
… have been obtained and processed. Heart motion, blood flow and noise cause the blur of the images. The objective of this thesis work was to study the effects of these factors on image quality and assess several models for image deblurring. The Wiener Filter and the Powei Spectrum …
-
Feasibility study of a moving hand support for surgery on the beating heart
… coronary bypass surgery on the beating heart is proposed, and entails the use of a heart-tracking support to move the hands of the surgeon in synchrony with the heart motion. This method eliminates the damaging effects associated with stopping or stabilizing the heart, while preserving …
-
Cardiac synchronized volumetric modulated arc therapy
Cardiac arrhythmias are abnormal heart rhythms that can adversely affect patients. The current treatment options include antiarrhythmic drug therapy and catheter ablation, both of which are associated with issues regarding efficacy and potential complications for complex arrhythmias. Cardiac …
-
Motion management optimization in radiotherapy : From the most common to the most uncommon patient
… To achieve this, it is important to have motion management methods for predicting, monitoring, and mitigating patient motion. These methods involve for instance adding extra margins around the target accounting for motion uncertainties, treatment in breath-hold, and imaging before and …
-
Noncontact Seismocardiogram Signal Detection Using Microwave Doppler Radar
… (SCG), a representation of mechanical heart motion, using microwave Doppler radar system. The increase in demand for health monitoring requires robust, reliable, and accurate remote detection of cardiac signals. Due to its ability to penetrate non-metal obstacles, microwave Doppler …
-
Guidance in the hybrid cardiovascular procedure for ventricular septal defect closure
… oxygenation process. VSDs are common congenital heart malformations that usually close by themselves; however, large VSDs require surgical treatment. A hybrid procedure aims to implant occluders to close VSDs during beating heart, being less invasive than the most common open heart surgery. The …
-
Optimizing reconstruction and segmentation of free-breathing whole-heart CMR to enable clinical implementation
… and segmentation of free-breathing whole-heart CMR to enable clinical implementation Yitong Yang 117 Pages Directed by Dr. John N. Oshinski Cardiac disease is the leading cause of death in the United States. Although bedside ultrasound is convenient to use and computational tomography (CT) …
-
Reduced-data magnetic resonance imaging reconstruction methods: constraints and solutions.
… cardiac applications, which involve respiratory motion and heart motion. With the introduction of reduced-data MR imaging methods, increasing acquisition speed has become possible without requiring a higher gradient system. But these reduced-data imaging methods carry a price for higher imaging …
-
Multimodal Predictive Frameworks for Cardiac Computed Tomography Gating
… CTA image quality is often degraded by cardiac motion artifacts. To reduce these artifacts, CTA commonly relies on electrocardiogram (ECG) gating to estimate cardiac quiescence, defined as the period of minimal cardiac motion. However, ECG reflects electrical activity rather than mechanical …
-
Compact Doppler radar system for heart rate detection
Periodic motion, such as that resulting from cardiopulmonary activity, can be measured with a microwave Doppler radar system. This thesis focuses on the assessment of radio system requirements and critical specifications for such radar sensing systems. The fundamental limitations for transmit …
-
Novel View Synthesis of Coronary Arteries from Rotational X-Ray Angiography
… NeRF architectures were explored to account for heart motion and the flow of contrast dye, addressing the dynamic nature of coronary artery imaging. However, the results from dynamic NeRF models, including attempts to merge RoDyNeRF with generative frameworks, were inconclusive, indicating the …
-
A framework for multi-physics simulations using four-chamber cardiac models
… creating cubic-Hermite meshes of the complex heart geometry. However, it is critical to accurately capture the different geometric characteristics of the heart and apply physiologically equivalent boundary conditions to replicate the in vivo heart motion. In this work, we created a …
-
A framework for multi-physics simulations using four-chamber cardiac models
… creating cubic-Hermite meshes of the complex heart geometry. However, it is critical to accurately capture the different geometric characteristics of the heart and apply physiologically equivalent boundary conditions to replicate the in vivo heart motion. In this work, we created a …
Page 1 of 2