Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 9 of 9 for “"Heart-Assist Devices"”.
-
Deep learning methods for the estimation of preload and physiological control of heart assist devices
Heart failure (HF) is one of the most prevalent life-threatening cardiovascular diseases, affecting more than 23 million worldwide. Although heart transplantation is the gold standard treatment for end-stage HF patients, the number of donor hearts is significantly less than the demand. Mechanical …
-
JOINT MICROFLUIDIC ASSESSMENT OF LOCAL SHEAR AND SHEAR HISTORICAL EFFECTS ON THROMBOSIS: APPLICATIONS TO HEART-ASSIST DEVICES AND HYPERINFLAMMATORY STATES
Heart failure repeatedly ranks as one of the leading causes of death worldwide, and the most practical therapeutic strategy is plagued with thrombotic complications. Treatment options for these patients are heart transplantation—which is met with low supply—and heart-assist device implantation. One …
-
In Vitro Flow Visualization Study of the Interface between Outflow Graft of Ventricular Assist Device and Aorta.
Heart transplant is often considered the best treatment for prolonged left ventricular failure. However due to limited donor hearts and ineligibility of some patients to get a transplant, heart assist devices are considered a short/long term option to assist the failing ventricle. Numerous in vitro …
-
Minimally Invasive Access to the Pericardium for the Active and Adjustable Cardiac Support Device
According to the American Heart Association, congestive heart failure affected 5.7 million Americans age 20 and older in 2006, and had an estimated direct and indirect cost of $37.2 billion in 2009. Heart assist devices are proving useful in a population where the demand for donor hearts is much …
-
Experimental investigation and mathematical modelling of human cardiovascular system during exercise
… non-invasive physiological parameters such as heart rate, respiration, working rate and body movement (using multiple triaxial accelerometers). The models developed could be incorporated as part of a closed loop control system for cardiac pacemaker and/or heart assist devices. A reliable …
-
Alternative heart assistance pump
On average, the human heart beats around 115,000, and pumps around 2,000 gallons of blood daily. This essential organ may undergo systolic or diastolic dysfunction in which the heart cannot properly contract or relax, respectively. To help hearts pump effectively should these types of failures …
-
Bestimmung links- und rechtsventrikulärer Funktionsparameter mittels Elektronenstrahlcomputertomographie bei Patienten vor und nach passiver Kardiomyoplastie
Die chronische Herzinsuffizienz gehört zu den weltweit häufigsten Erkrankungen mit steigender Inzidenz. Trotz optimaler medikamentöser Therapie ist die Lebenserwartung von Patienten mit manifester Herzinsuffizienz verkürzt. Pathophysiologisch führt eine systolische Dysfunktion des Myokards …
-
Experimental and Computational Assessment of Mechanical Circulatory Assistance of a Patient-Specific Fontan Vessel Configuration
… teams caring for patients with congenital heart disease. Those patients fortunate to survive surgical palliation contend with lifelong physical limitations and late stage pathophysiology. A mechanical blood pump specifically designed to increase pressure in the great veins would augment …