Results 1 to 18 of 18 for “"Heartbeat Detection"”

  1. Heartbeat detection, classification and coupling analysis using Electrocardiography data

    … (online) ECG analysis algorithms that include heartbeat detection and ECG arrhythmia classification. We first propose a novel phase space based method for heartbeat detection that maps the ECG data into a two-dimensional reconstructed attractor. Unlike conventional algorithms, our detector …

    ohiolink Repository record for Heartbeat detection, classification and coupling analysis using Electrocardiography data (opens in a new tab)

  2. Exploring passive heartbeat detection using a hydraulic bed sensor system

    Sleep monitoring of heartbeat, respiration and restlessness can help to detect sleep disturbances which may be indicative of poor health and functional deficits, especially in older adults. This work investigates a new hydraulic bed transducer configuration in order to improve its ability to …

    missouri Repository record for Exploring passive heartbeat detection using a hydraulic bed sensor system (opens in a new tab)

  3. Effects of exercise on heartbeat detection and self-focus in social anxiety

    Social anxiety (SA) is one of the most common psychological disorders, with a lifetime prevalence rate of 13%. Further, SA is accompanied by various distressing (e.g., negative emotions, perception of poor social skills) and impairing (e.g., attentional bias, social avoidance) symptoms. Of these …

    okstate Repository record for Effects of exercise on heartbeat detection and self-focus in social anxiety (opens in a new tab)

  4. Short-term heart rate variability as a general indicator of health estimated by ballistocardiography using a hydraulic bed sensor in elder care

    A new approach for an accurate heartbeat detection algorithm for ballistocardiographic signals using combined clustering techniques (k-means and fuzzy C-means) for template extraction followed by template matching is presented, which delivered a 99.9 % accuracy of heartbeat detection. Improved …

    missouri Repository record for Short-term heart rate variability as a general indicator of health estimated by ballistocardiography using a hydraulic bed sensor in elder care (opens in a new tab)

  5. Unobtrusive ultra-short-term HRV analysis for the identification of physiological states in healthy people

    … arousal states, and postural changes. Accurate heartbeat detection is essential for reliable HRV calculations, which are critical for both clinical diagnostics and consumer health applications. This requires identifying QRS peaks in ECG signals or pulses in PPG signals and improving quality …

    barcelona Repository record for Unobtrusive ultra-short-term HRV analysis for the identification of physiological states in healthy people (opens in a new tab)

  6. Extracting ECG-based cardiac information from the upper arm

    … study examines how various state-of-the-art heartbeat detection algorithms perform in four levels of simulated EMG artifacts. The simulated EMG was added to Lead II from two different datasets: the MIT-BIH arrhythmia dataset (Dataset 1) and data we collected from 20 healthy participants …

    waterloo Repository record for Extracting ECG-based cardiac information from the upper arm (opens in a new tab)

  7. Measurement of interoception and its role in autism and anxiety

    Interoception, defined as the detection and interpretation of internal sensory information, is said to underlie a number of psychological processes. Despite considerable research into interoception, our understanding remains limited. This thesis had two primary objectives. First, to critically …

    oxford Repository record for Measurement of interoception and its role in autism and anxiety (opens in a new tab)

  8. Measuring mindful interoception : development of the mindful interoception sampling task (MIST).

    … were administered the MIST and the Schandry heartbeat detection task, a widely used behavioral measure of interoception. A battery of questionnaires was also administered, and resting heart rate and blood pressure were recorded. Results of this study indicate the MIST is a valid behavioral …

    louisville Repository record for Measuring mindful interoception : development of the mindful interoception sampling task (MIST). (opens in a new tab)

  9. Emotion experience and physiology in response to masked and non-masked presentations of emotional pictures

    … elicited by masked stimuli was unrelated to heartbeat detection ability, cardiac vagal tone, or self-reported attention to emotional states, though self-reported emotional clarity predicted better arousal discrimination. It is proposed that awareness of emotion experience may involve both a …

    arizona-thes Repository record for Emotion experience and physiology in response to masked and non-masked presentations of emotional pictures (opens in a new tab)

  10. Συσχέτιση της ιδιοπαθούς αρτηριακής υπέρτασης με ψυχιατρική συμπτωματολογία

    … monitoring (ABPM) provides a useful tool in the detection and evaluation of hypertension and in the assessment of abnormalities in blood pressure circadian pattern, such as a lack of nocturnal BP, related with increased cardiovascular risk. The aim of this study was 1) to compare newly diagnosed …

    greece Repository record for Συσχέτιση της ιδιοπαθούς αρτηριακής υπέρτασης με ψυχιατρική συμπτωματολογία (opens in a new tab)

  11. Optical system design of a laser-based stethoscope

    … to visualize the heart beat signal. This heartbeat detection technique could overcome the limitation of the acoustic stethoscope brought by the poor ability of human ears to hear low frequency heart sounds. This is important, as valuable information from sub-audio sounds is present at …

    umn Repository record for Optical system design of a laser-based stethoscope (opens in a new tab)

  12. Intelligent ECG processing and abnormality detection using adaptive ensemble models

    … to process raw ECG signals for abnormality detection. The work is divided into three main stages which serve towards the main aim of this research, i.e. the abnormality detection from single channel raw ECG signals. In the first stage, a lightweight baseline correction algorithm is proposed …

    northumbria Repository record for Intelligent ECG processing and abnormality detection using adaptive ensemble models (opens in a new tab)

  13. The Role of Psychological Flexibility within the Detection and Regulation of Emotion

    … to explore the relationship between PF and the detection and regulation of emotion in a non-clinical sample, in order to test the theoretical basis of ACT. Method: Interoception was assessed using a heartbeat detection task, where participants are asked to count their own perceived heartbeats in …

    whiterose Repository record for The Role of Psychological Flexibility within the Detection and Regulation of Emotion (opens in a new tab)

  14. Online and Continuous Electrocardiogram (ECG) Biometric System

    … developed an online abnormal electrocardiogram heartbeat detection and removal using one-class Gaussian mixture model of two components. This outlier removal method was implemented in a biometric system and was examined on a 1,012 fingertip acquired ECG signals database. The biometric system had …

    toronto-retro Repository record for Online and Continuous Electrocardiogram (ECG) Biometric System (opens in a new tab)

  15. Detection of heartbeats in wireless signal

    Doppler radar remote detection of heart activity is a promising technique for unobtrusive health monitoring and life sensing. However, so far this approach has been limited to practical use. The difficulty lies in distinguishing targeted heartbeat signals from artifacts produced by the presence of …

    hawaii Repository record for Detection of heartbeats in wireless signal (opens in a new tab)

  16. An investigation of the bodily self in eating disorders

    … from the previous three studies and used a heartbeat detection task (HBDT) to focus specifically on interoception. The findings did not demonstrate significant differences between the ED and HC groups on interoceptive sensitivity as indexed by the HBDT. However, the HBDT did not appear to be …

    anu Repository record for An investigation of the bodily self in eating disorders (opens in a new tab)

  17. Contribution à l'amélioration des performances d'une chaîne de mesure de la fréquence cardiaque en milieu bruité

    Les activités liées au développement d’objets connectés munis d’intelligence embarquée ont connu un essor considérable ces dernières années, en particulier pour les applications médicales. Dans ce contexte, une course effrénée s’est engagée entre les pionniers de l’IoT afin d’offrir des produits …

    star-france Repository record for Contribution à l'amélioration des performances d'une chaîne de mesure de la fréquence cardiaque en milieu bruité (opens in a new tab)