Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Heat flow meter"”.
-
Development and Commissioning of a Large-scale Rotatable Guarded Hot Plate Apparatus
… specimens containing layers and/or complex 3D heat flows (i.e. thermal bridges). The apparatus is capable of accepting specimens measuring 4’ (1219mm) by 4’ (1219mm) and up to 16” (406mm) thick with good accuracy in measurement. Computer models were developed to estimate heat flow errors …
-
Thermal Conductivity of foamed concrete
… is presented. Experiments were done using a heat flow meter according to ASTM C 518-02. The experimental results show that thermal conductivity decreases with increasing foam content, water-cement ratio and increasing polymer content. Numerical analysis using FLUENT software shows that …
-
Development of Characterization of 3D-Printed Continuous Pitch Carbon Fiber Composites
… pitch carbon fiber and how various printing parameters affect thermal conductivity of samples. An initial prototype 3D printer was made with a custom dual nozzle extruder to print pitch carbon fibers, initial samples were measured with 37.1 W/mK effective thermal conductivity, this was much lower …
-
Polyurethenae foams and engineering education
… of physical blowing agent was characterized by a heat flow meter for [subscript], and a pycnometer for the foam density and closed cell content. Besides, heat capacities (𝐶𝑃) of most common polyols and isocyanate in making PU foams were experimentally measured. Then a general formula was created …
-
EFFECT OF MOISTURE ON THERMAL INSULATION
… moisture levels. Two experimental rigs viz. the heat-flow-meter apparatus and the environmental chamber, both incorporating an automatic data acquisition system are developed for the investigation. Dry and moist insulation slabs are tested on the heat-flow-meter apparatus. The results reveal …
-
Characterization and Modeling of the Thermal Properties of Photopolymers for Material Jetting Processes
… portion of that lost energy is converted into heat. Embedding electronics in PolyJet parts is of particular interest since material jetting additive manufacturing has the ability to deposit multiple, functionally graded materials on a pixel by pixel basis. Although there is existing literature …
-
Thermal performance of closed-cell foam insulation board under different temperature conditions
… conditions in roof constructions. Based on heating degree days (HDD), ten different cities were selected between climate Zone 4 (HDD<3000) to Zone 8 (HDD≥7000). The thermal resistance measurements were conducted using heat flow meter apparatus on four polyiso insulation boards (two new and …
-
Thermal conductivity characterization of composite materials
… fiber volume fraction, direction of heat flow, and service temperature. Recognizing the thermal responses in Fiber Reinforced Polymer (FRP) composite decks play a critical role in their performance, accurate thermal measurements of FRP decks are essential.;The objective of the …
-
PYROLYSIS MODELING AND MATERIAL PROPERTY VALIDATION WITH FLAME HEAT FEEDBACK MODEL APPLICATION
… of Standards and Technology (NIST) with flame heat feedback application. Heat flow meter (HFM) and Integrating sphere were utilized to measure thermal conductivities and emissivity values for the materials. Thermogravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC), Microscale …
-
Predicting the thermal performance of bio-based cold chain packaging system
… design, and environmental factors influence heat transfer. This research combines experimental and computational approaches to improve the thermal efficiency and environmental sustainability of passive cold chain packaging systems. The first phase of the study (Chapter 1) focuses on …
-
Long-term Functionality of Vacuum Insulation Panels (VIP) Subjected to Simulated Random Vibrations
… D4169 and D4827. Aged specimens underwent ’heat’ (70 ±1°C and 5 ±3 % RH) aging in an oven and ‘heat & vapour’ (70 ±1°C and 95 ±3 % RH) aging in a specialized environment chamber for up to 120 days before going through random vibration tests. The change of thermal conductivity of each …
-
Characterization of thermal and electrical properties of Fiber Reinforced Polymer (FRP) composites
… fiber volume fraction, direction of heat flow, and service temperature. Recognizing the thermal responses in Fiber Reinforced Polymer (FRP) composite decks play a critical role in their performance, accurate thermal measurements of FRP decks are essential. A major focus has been …
-
A Study of Thermal Energy Storage of Phase Change Materials: Thermophysical Properties and Numerical Simulations
… use. The main types of a TES system are sensible heat and latent heat. A latent heat storage is a very efficient method for storing or releasing thermal energy due to its high energy storage density at constant temperatures, and a latent heat storage material can store 5-14 times more heat per …
-
Thermal-Mechanical Precast Concrete Panels Comprised Of Hybrid-Polymerized Sandwich Interfaces For High-Impact Projectile Resistance
… energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy …
-
Hygrothermal performance of hempcrete infill wall systems in cold climates
… properties of the hempcrete were obtained with heat flow meter Fox314, whereas the hygrothermal analysis of wall assemblies was performed using WUFI soft-ware. The densities of hempcrete samples produced in this study show excellent con-sistency, ranging from 298.55 kg/m3 to 318.05 kg/m3, with …
-
Ανάπτυξη και εφαρμογή μετρητικών και υπολογιστικών μεθοδολογιών για την αξιολόγηση ενεργειακής απόδοσης δομικών στοιχείων με ιδιότητες αλλαγής φάσης
… based on the innovative concept of the dynamic heat flow meter apparatus (DHFMA). The main benefits of the DHFMA come from its ability to test large specimens of PCM enhanced building materials. Starting with a fundamental theoretical analysis of the DHFMA under dynamic operation, the main …
-
Air-gap Electrical Windings for Light-weighting of Future Electric Propulsion Systems
… a shear strength testing rig and an experimental heat flow meter, respectively. <br/>In collaboration with the National Composites Centre the manufacture of a composite airgap winding stator is demonstrated using novel resin transfer moulding techniques, and the prototype is tested to validate the …
-
Study of the effect of RF synthesis parameters on the superinsulating properties of xerogel composite blankets
… on the xerogel blankets were performed using a heat flow meter (HFM) assembly. The obtained results specify that the thermal conductivity of the composite blankets tends to decrease with increasing average pore size, towards a critical value, which is less than the mean free path of air. There …
-
Super Insulating Materials for energy efficient buildings: thermal performance and experimental uncertainty
… experimental apparatuses, such as the Heat Flow Meter (HFM) and the Guarded Hot Plate (GHP), and in accordance with as traditional standard, developed for the most common insulating material. Indeed, at the first stage of this research, the applicability of the current methodologies was …
Page 1 of 2