  1. Transient heat transfer

    … a more thorough understanding of the heat transfer characteristics of liquid nitrogen is required. In our investigations we examine the transient heating characteristics of liquid nitrogen to states of nucleate and film boiling under different liquid flow conditions. Using a platinum …

    portland-state Repository record for Transient heat transfer (opens in a new tab)

  2. Perfusion and heat transfer in the canine prostate

    … diseases has motivated efforts to analyze heat transfer in the prostate. In order to develop an accurate heat transfer model of living tissue, the complex interaction of perfusion and heat transfer must be addressed. An initial step to quantifying the effect is to measure the normal …

    texas Repository record for Perfusion and heat transfer in the canine prostate (opens in a new tab) Restricted access

  3. The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point

    Two rapid-response thin-film heat flux gage systems have been used to measure time-resolved unsteady heat transfer signals. The Heat Flux Microsensor is a passive gage which measures the temperature difference across a thin thermal resistance. The second sensor, an actively powered gage operated by …

    vt Repository record for The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point (opens in a new tab)

  4. The performance of a thermal transient anemometer (TTA) for nonuniform velocity measurements

    … wire which provides an area- averaged velocity measurement. The measuring strategy relies on the transient convection and the temperature decay of the sensing wire, which is correlated with the magnitude of the velocity. The relationship between the temperature decay and the velocity is …

    msu Repository record for The performance of a thermal transient anemometer (TTA) for nonuniform velocity measurements (opens in a new tab)

  5. Design and development of a multi-axis controlled thermal scanner

    Surface temperature measurement is applicable to a vast number of fields including manufacturing, processing, agricultural, medical and pharmaceutical fields just to name a few. Two methods for obtaining surface temperature measurements exist; ‘surface contact measurement’ in which the measuring …

    nmmu Repository record for Design and development of a multi-axis controlled thermal scanner (opens in a new tab)

  6. Development of radiative emission concentration sensors

    Includes bibliographical references.

    colo-mines Repository record for Development of radiative emission concentration sensors (opens in a new tab)

  7. Measurement and Mapping of Pulse Combustion Impingement Heat Transfer Rates

    … use. Pulse combustion impingement has higher heat transfer rates and a lower impact on the environment. Commercialization of pulse impingement drying is the goal of the Pulsed Air Drying group at IPST. To that end the objective of this project is to develop a system that will allow researchers …

    gatech Repository record for Measurement and Mapping of Pulse Combustion Impingement Heat Transfer Rates (opens in a new tab)

  8. Design and calibration of a rapid-response thin-film heat flux gage

    A local heat-flux measurement system was built, calibrated and tested for use in unsteady flows. The system was designed to maintain constant wall temperature boundary conditions. The measuring element is a thin-film heat flux gage made by sputter-coating gold on a substrate. A constant-temperature …

    vt Repository record for Design and calibration of a rapid-response thin-film heat flux gage (opens in a new tab)

  9. Ensemble Kalman Filter Data Assimilation in the Presence of Large Model Error

    … observed data from the summer of 2004. Sensible heat flux estimates are calculated from Oklahoma Mesonet observations of temperature and wind using an iterative profile method reliant on boundary layer similarity theory. These sensible heat flux estimates are assimilated into the MM5 model, …

    oklahoma-thes Repository record for Ensemble Kalman Filter Data Assimilation in the Presence of Large Model Error (opens in a new tab)

  10. Long-term measurements of spatially-averaged sensible heat flux for a mixed grassland community, using surface layer scintillometry.

    … fluxes have been developed and tested. Direct measurements of fluxes are usually achieved by the eddy covariance (EC) method, which is considered as the most reliable. However, the application of the EC method is often problematic. The necessary sensors for wind, temperature and humidity must …

    ukzn Repository record for Long-term measurements of spatially-averaged sensible heat flux for a mixed grassland community, using surface layer scintillometry. (opens in a new tab)

  11. Nonuniform flow over a thermal transient anemometer

    … that holds a tungsten sensing wire that was heated with an electrical current and cooled with a passing flow. The TTA was then simulated, using an energy balance equation as a basis, to test with more nonuniform flows. The source of axial heat transfer caused the TTA to cool slower with a …

    msu Repository record for Nonuniform flow over a thermal transient anemometer (opens in a new tab)

  12. Sensible heat flux under unstable conditions for sugarcane using temperature variance and surface renewal.

    … evaporation involves measuring the sensible heat flux (H) from which latent energy flux and hence total evaporation can be calculated, as a residual using the shortened energy balance from measurements of net irradiance and soil heat flux. Various methods for measuring H may include Bowen …

    ukzn Repository record for Sensible heat flux under unstable conditions for sugarcane using temperature variance and surface renewal. (opens in a new tab)

  13. Dynamic, In-Situ Pressure Measurements during CMP

    … was successfully constructed. Interfacial fluid measurements were performed with various slurries, slurry flow rates, and pad topographies. It was experimentally determined that the pad topography has the biggest effect in pressure and temperature distribution. This was also confirmed by tilt …

    gatech Repository record for Dynamic, In-Situ Pressure Measurements during CMP (opens in a new tab)

  14. Heat and energy exchange above different surfaces using surface renewal.

    … equation for which advection and stored canopy heat fluxes are neglected, the measurement of net irradiance, soil heat flux, and sensible heat flux allows the latent energy flux and hence the total evaporation amount to be estimated. The SR method for estimating sensible heat, latent energy, and …

    ukzn Repository record for Heat and energy exchange above different surfaces using surface renewal. (opens in a new tab)

  15. Seasonal variation of surface energy fluxes above a mixed species and spatially homogeneous grassland.

    … indirect or direct estimation of sensible heat flux then calculating latent energy flux and hence total evaporation as a residual of the shortened energy balance equation. The main objective of this study is to determine the effects of grassland management practices on the energy balance …

    ukzn Repository record for Seasonal variation of surface energy fluxes above a mixed species and spatially homogeneous grassland. (opens in a new tab)