Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 25 for “"Heat-cured"”.
-
Performance of Green Smart-Heat Cured Cementitious Materials
… solution. However, the high energy intensity heat curing process for precast elements represents a challenge. On the other hand, microencapsulated phase change materials (MPCMs) was used to improve cementitious material thermal storage capacity. However, a reduction in mechanical properties …
-
Characterization of heat cured and transglutaminase cross-linked whey protein-based edible films
Thesis (Ph. D.)--Michigan State University. Food Science, 2008
-
The Effect of Cement and Blast Furnace Slag Characteristics on Expansion of Heat-Cured Mortar Specimens
… make them cheaper than casting on site [1]. Heat curing of precast concrete is conducted to obtain high early-strength. However, in doing so, durability issues can arise in the form of internal sulfate attack also known as DEF, if the internal temperature of concrete exceeds 70°C. Past this …
-
Antifungal Efficacy And Flexural Strength Of Silver Nanoparticles Reinforced Cad/Cam And Heat-Cured Pmma Polymers: An In-Vitro Study
… and flexural strength of CAD/CAM printed and heat-cured PMMA polymers. Materials and methods: A total of 110 samples (66 unmodified and 44 modified with SNP) of three different denture materials, heat-cured PMMA (Lucitone 199, Dentsply International Inc., York, PA, USA), CAD/CAD milled …
-
In Vitro Evaluation of Candida albicans Adherence and Disinfection Techniques on CAD/CAM Milled, 3D Printed, and Heat-Cured PMMA
… various types of polymers commonly: CAD/CAM or heat-cured. C. albicans adherence rate to these polymers and disinfection efficacy of adherent fungal biofilms are multifactorial processes and differ depending on the physical characteristics of the targeted surface. PURPOSE: The purpose of this …
-
GENOTOXICITY ASSESSMENT OF CONVENTIONAL AND CAD/CAM DENTURE BASE MATERIALS
… properties compared to the standard conventional heat-cured denture base material. However, their long-term biocompatibility remains unstudied. Therefore, this study evaluates the genotoxicity effects of conventional and CAD/CAM denture base materials on human gingival fibroblasts (HGFs). …
-
Study of microtip-based extraction and purification of DNA from human samples for portable devices
… DNA from human samples is presented by using heat-cured polyethyleneimine-coated microtips generating a high electric field. The microtip extraction method is based on recent work using an electric field and capillary action integrated into an automated device. The main challenges to the …
-
APPLICATION OF CELLULOSE BASED NANOMATERIALS IN 3D-PRINTED CEMENTITIOUS COMPOSITES
… and reduces the porosity of 3D-printed OPC and heat-cured AAM samples. Further, the addition of CNC (up to 0.30%) in sealed-cured AAM samples improves their flexural strength due to the crack-bridging mechanism of CNCs. The addition of CNC densifies the microstructure of OPC samples by …
-
An Evaluation of Subcutaneous Tissue Reaction to Acrylic Resin Implants
… formation and necrosis. In 1960 a new vacuum-heat curing technique was used in processing ethylethacrylate. The final product was poly ethylethacrylate, a resin attributed by its manufacturer to demonstrate highly inert properties. Little research has been done, however, to substantiate this …
-
On the Development of 8,000 psi Geopolymer Mortar for Practical Use in Field Applications
… guidelines for mixture design and often require heat curing to facilitate strength gain. Additionally, many geopolymers are created using carefully controlled and high quality materials and activator chemicals. These factors greatly affect the practicality of the material. The goal of this …
-
Effect of Tricalcium Silicate Content on Expansion in Internal Sulfate Attack
… of sulfate, and alkalis. The bars were then heat cured at various temperatures and stored in a saturated lime solution at room temperature. Measurements were made at predetermined time intervals. The series of mixes were made to determine the effect of varying sulfate levels, heat curing …
-
COMPARING THE MECHANICAL PROPERTIES OF CONVENTIONAL, MILLED, AND 3D-PRINTED OCCLUSAL SPLINT MATERIALS: AN IN VITRO STUDY
… occlusal splint materials versus conventionally heat-cured acrylic resin materials. Materials and Methods: A total of 100 specimens were manufactured for the present study. One CAD-CAM milled (ProArt CAD Splint), one heat-polymerized (SR IVOcap Clear), and three 3D-Printed (KeySplint Hard, …
-
Wettability of saliva substitutes on CAD/CAM denture base materials
… denture bases: C (conventional; Lucitone 199 heat cured), M (milled), P (printed), I (injection molded; Ivocap), and F (flexible; Ultraflex). Phase 3 measured CA of 5 saliva substitutes – Biotene, VEGA, Spry, Moi-Stir, and Dentilube – on the 5 polished denture bases. Ten droplet measurements …
-
The fabrication of an acrylic repositioning stent for use during intensity modulated radiation therapy (IMRT) : a feasibility study
… and the customized wax pattern was processed in heat-cured clear hard acrylic overnight. Measuring the Stability of the Patient Position: Utilizing data from the daily KeV images, the relative stability of the patient setup was assessed. Monitoring of side effects: Participants completed a …
-
Oral Mucosal Response to Dental Prostheses
… and measurable epithelial parameters. Individual heat-cured acrylic appliances were constructed. Within each dietary group, animals were allocated to a control group, or one of two test groups, wearing an appliance for periods of either 7 or 14 days. Tissue was analysed using computerised …
-
Time-Temperature Curing Relationship of an Adhesive Binder with Rice Straw
… formed from compressed rice straw and a heat-cured adhesive – may overcome challenges associated with straw bale building. However, the times and temperatures needed to cure the binder with straw are not well understood. Therefore, the goal of this thesis was to study straw cubes (in lieu …
-
In Vitro Comparison of Cellular Cytoxicity of Conventional vs. Cad/Cam Denture Base Materials
… fabricated denture bases versus conventionally heat-cured acrylic resin materials. Materials and Methods: In total, 75 disks of five different denture resin materials – 15 disks per group were prepared: Ivocap (group 1; control), Ivotion denture base (group 2), Lucitone 3D denture base (group …
-
Damage modelling procedure and fastener positioning optimization of adhesively reinforced frictional interfaces
… is formulated for room temperature- and heat-cured adhesives. Model parameters are fitted using regression analysis. Decohesion finite elements involving the cohesive zone model are adapted to model progressive degradation of the reinforced interfaces. A non-local friction law is also …
-
Transparent Omniphobic Coatings that are Flexible and Wear Resistant
… PEMA. The resultant grafted polymer was further heat-cured with the chemically blending of cycloaliphatic epoxy-functionalized oligosiloxanes (CEOS). Only 2.8 wt% of polydimethylsiloxane (PDMS) existing in the coating matrix can impart the anti-smudge properties. Test liquids with various surface …
Page 1 of 2