Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"Heated passive headspace concentration"”.
-
Evaluating the recovery of DNA after heated passive headspace concentration
… DNA analysis can be performed effectively after heated passive headspace concentration, without causing irreparable degradation to DNA evidence. Heated passive headspace concentration is a common procedure for extracting ignitable liquids from a substrate to identify and confirm the presence of …
-
Impact of heated passive headspace concentration on DNA recovery from semen in fire-scene evidence
Heated passive headspace concentration (HPHC) is routinely employed to recover ignitable-liquid residues from fire debris, but the elevated temperatures used may compromise subsequent DNA analysis when biological traces are present on the same exhibit. This study evaluated the feasibility of …
-
Evaluation of chemical attribution signatures within gasoline over time using direct analysis in real time mass spectrometry and principal component analysis
… analysis of gasoline extracts collected from heated passive headspace concentration was completed to evaluate its efficacy at extracting higher molecular weight additives. During initial experiments, the heated passive headspace concentration procedure was not efficient at extracting and …
-
Improving oxygenated ignitable liquid recovery by dual-mode heated passive headspace extraction using zeolites and activated charcoal strips
Heated passive headspace concentration is presently the most commonly utilized technique for the extraction of ignitable liquid residues from fire debris evidence. This process, introduced by William Dietz in 1991, typically involves suspending an activated charcoal strip within an airtight …
-
DNA recovery potential in simulated fire debris evidence
… to different time and temperature conditions of heated passive headspace concentration (HPHC) were compared to determine if it was advisable to perform HPHC in an attempt to recover volatile ignitable liquid evidence prior to testing for DNA. The HPHC overall had no significant effect on the …
-
The study of volatile organic compounds associated with decomposition of pig tissue as a model for human decomposition
… compounds associated with human decomposition. Heated passive headspace concentration with activated carbon as the adsorbent material followed by analysis with GC/MS was tested for its reliability in recovering and detecting volatile organic compounds of decomposition. The volatile organic …
-
Recovery of oxygenated ignitable liquids from mock fire debris utilizing zeolite 13X
… that the use of zeolite 13X as an adsorbent in heated passive headspace concentration provides increased recovery of oxygenated compounds in comparison to the conventional activated charcoal adsorbent. This hypothesis was further tested in this work using more realistic casework scenarios. …