Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"Helmholtz coil."”.

  1. Design and construction of helmholtz coil for biomagnetic studies on soybean

    A Helmholtz coil with a large usable area of uniform field was designed, constructed and characterized, specifically for bioelectric studies. The design and analysis of the coil were carried out through experiments and the use of industry standard electromagnetic software suite. The location and …

    missouri Repository record for Design and construction of helmholtz coil for biomagnetic studies on soybean (opens in a new tab)

  2. Design and Evaluation of a Novel Thermal Management System for a One-Dimensional Helmholtz Coil System

    … an innovative one-dimensional liquid-cooled Helmholtz coil configuration is presented. This design has been developed to generate a strong, uniform magnetic field of up to 0.3 Tesla, which will be used to manipulate small-scale magnetic robots for applications in minimally invasive surgery, …

    ttu Repository record for Design and Evaluation of a Novel Thermal Management System for a One-Dimensional Helmholtz Coil System (opens in a new tab)

  3. Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil

    … experiment. However, only two kinds of detector coils have been typically used in NMR studies. These are the solenoid coil and the Helmholtz coil. The solenoid coil was very popular with the permanent and electromagnet NMR instruments. With the advent of the superconducting magnets the popularity …

    vt Repository record for Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil (opens in a new tab)

  4. Magnetic Field Shielding For the Forward Time of Flight Upgrade At Jefferson National Lab

    … types of magnetic shielding methods using a Helmholtz Coil to provide varying field strengths. Photomultiplier tubes with magnetic shielding built in supply the necessary shielding for the strengths expected at Jefferson Lab, though there are still other options available if need be.

    south-carolina Repository record for Magnetic Field Shielding For the Forward Time of Flight Upgrade At Jefferson National Lab (opens in a new tab)

  5. A novel magnetic field approach to simulate spacecraft attitude determination and control

    … 3-axis attitude control via magnetic torque coils and attitude determination via Kalman-filtered magnetometer data with an optional Sun vector measurement. This innovative new attitude determination and control (ADC) method is more sophisticated than those traditionally employed on CubeSats …

    uiuc Repository record for A novel magnetic field approach to simulate spacecraft attitude determination and control (opens in a new tab)

  6. Deleterious Synergistic Effects of Concurrent Magnetic Field and Superparamagnetic (Fe3O4) Nanoparticle Exposures on CHO-K1 Cell Line

    … and 100Hz) 2.0mT magnetic fields produced by a Helmholtz coil pair. The cells were then observed under confocal fluorescence microscopy, and subject to MTT biological assay to determine the synergistic effects of these concurrent exposures. No effects were observed on cell morphology or …

    unt Repository record for Deleterious Synergistic Effects of Concurrent Magnetic Field and Superparamagnetic (Fe3O4) Nanoparticle Exposures on CHO-K1 Cell Line (opens in a new tab)

  7. Design, assembly, programming, and testing of triaxially-nested Helmholtz coils, The

    … and testing of tri-axially nested square Helmholtz coils. A novel geometric approach is presented which enables the reader to reduce the overall size of the Helmholtz assembly without sacrificing any volume in the workspace. Included in the Appendix of this thesis are all of the mechanical …

    colo-mines Repository record for Design, assembly, programming, and testing of triaxially-nested Helmholtz coils, The (opens in a new tab)

  8. MegaGauss : a portable 40T magnetic field generator

    … severe effects the miniature field-generating Helmholtz coil experiences due to the current pulse and magnetic field. Finally, a novel data archive scheme, structured around the familiar MDSplus archive system, is implemented in Labview and integrated into the main pulsed power control program. …

    texas Repository record for MegaGauss : a portable 40T magnetic field generator (opens in a new tab)

  9. Theoretical and Experimental Study for Tailoring the Electromagnetic Properties of Conductive Materials

    … dissertation addresses these complexities. An Helmholtz coil and other loops positioned in a coaxial array were used to create and monitor inductive fields that were mathematically related to the induced current in closed, circular loops with electrical conductivities ranging from 1.0 to 57 …

    ucf Repository record for Theoretical and Experimental Study for Tailoring the Electromagnetic Properties of Conductive Materials (opens in a new tab)

  10. DROPS-ON-STILTS MICROROBOTS FOR TRANSPORT AND DELIVERY OF HYDROPHOBIC CARGO

    … including therapeutic agents. Using a 3D Helmholtz coil to generate uniform rotating magnetic fields, we induce the assembly of IONPs and droplets into stilt-like architectures that lift and mobilize droplets across surfaces. The formation of these structures depends critically on particle …

    penn Repository record for DROPS-ON-STILTS MICROROBOTS FOR TRANSPORT AND DELIVERY OF HYDROPHOBIC CARGO (opens in a new tab) Embargoed until 2029-01-29

  11. Energy deposition into heavy gas plasma via pulsed inductive theta-pinch

    … into plasma via formation in a theta pinch coil. To aid in this research, the Missouri Plasmoid Experiment Mk. I (and later Mk. II) was created. In the first paper, the construction of differential magnetic field probes are discussed. The effects of calibration setup on B-dot probes is …

    must-thes Repository record for Energy deposition into heavy gas plasma via pulsed inductive theta-pinch (opens in a new tab)

  12. DESIGN, FABRICATION AND CHARACTERIZATION OF ZERO POWER SENSOR/HARVESTER FOR SMART GRID APPLICATIONS

    … films. The thin film sensors were tested using a Helmholtz coil and their response were determined in terms of tip deflection and current gained.

    unm Repository record for DESIGN, FABRICATION AND CHARACTERIZATION OF ZERO POWER SENSOR/HARVESTER FOR SMART GRID APPLICATIONS (opens in a new tab)

  13. The Simulation, Composition and Shielding of Radiation-Induced X-ray-like Background in Space-Based X-ray Astronomy Missions

    … locations, and the demonstration that a Helmholtz coil magnetic field structure could be used to significantly reduce the background induced by both low energy fully absorbed electrons, and backscattering electrons. Much of the simulation work in this thesis was performed on geometries …

    the-open-u Download PDF for The Simulation, Composition and Shielding of Radiation-Induced X-ray-like Background in Space-Based X-ray Astronomy Missions (opens in a new tab)

  14. Metamaterial-enabled near-field engineering for magnetic resonance imaging

    … local magnetic field distribution produced by RF coils and resonant structures. Conventional strategies to improve SNR primarily rely on increasing coil channel count or refining coil geometry, which inevitably introduce added system complexity, cost, and practical constraints. This dissertation …

    bu Repository record for Metamaterial-enabled near-field engineering for magnetic resonance imaging (opens in a new tab)

  15. Engineering Considerations for Treatment of Prosthetic Joint Infections Using Alternating Magnetic Fields (AMF)

    … this thesis, first an AMF system with a solenoid coil was constructed for targeting a metal plate surgically implanted in a sheep model. The system produced magnetic field strengths up to 12 mT and achieved plate temperatures of 65-80°C within 10-14 seconds. A tissue-mimicking phantom of the sheep …

    utswmed Repository record for Engineering Considerations for Treatment of Prosthetic Joint Infections Using Alternating Magnetic Fields (AMF) (opens in a new tab)

  16. Numerical and experimental methods applied to human exposure to electromagnetic fields

    … frequency range has been carried out around a Helmholtz coil system enclosed by a wooden frame, which is used to position the 3D magnetic eld probe. Numerous eld distributions can be generated through this system by separately imposing the currents which supply the two coils, and three of them …

    poli-torino Repository record for Numerical and experimental methods applied to human exposure to electromagnetic fields (opens in a new tab)

  17. Pre-Initiation Features Investigation and Helical Structure Formation in Solid Metal Liner Z-Pinches

    … to the liner, generating a time-varying Bz, or a Helmholtz coil, generating a steadystate Bz. We show that an upward external axial magnetic field generates a lefthanded twist of the helical pattern and a downward field a right-handed twist. We further show that the helix angle does not correspond …

    cornell Repository record for Pre-Initiation Features Investigation and Helical Structure Formation in Solid Metal Liner Z-Pinches (opens in a new tab)

  18. Microstructural formations and phase transformation pathways in tantalum carbides

    … load on a test bar specimen. The electromagnetic Helmholtz coil can be used to independently control the magnetic flux, or load, while adjusting the specimen current for resistive heating of the specimen. The coils and specimen were encased in a stainless steel chamber that controlled the testing …

    alabama Repository record for Microstructural formations and phase transformation pathways in tantalum carbides (opens in a new tab)

  19. Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications

    … controlled through a solenoid and rectangular Helmholtz coil, both built in-house. A three-dimensional magnetic field vector sensor was proposed due to the success of the magnetic field sensor, and a design was proposed and initially tested to validate direction as a function of field strength …

    vt Repository record for Fully Distributed Multi-Material Magnetic Sensing Structures for Multiparameter DAS Applications (opens in a new tab)

  20. Real time novel observations of net quantum magnetism in macroscopic matter with a nanomagnetic ferrolens and emulation and extrapolation of a spin relativistic electromagnetic flux manifold fiber model for the quantum magnet (electron at rest)

    … like for example, inside electrical solenoids or Helmholtz coils (Helmholtz coil was constructed in our Institution by the thesis author). Another, novel application and published research of the ferrolens the author presents herein, is for the real time display of dynamic (changing) magnetic …

    greece Repository record for Real time novel observations of net quantum magnetism in macroscopic matter with a nanomagnetic ferrolens and emulation and extrapolation of a spin relativistic electromagnetic flux manifold fiber model for the quantum magnet (electron at rest) (opens in a new tab)