  1. Design, assembly, programming, and testing of triaxially-nested Helmholtz coils, The

    … and testing of tri-axially nested square Helmholtz coils. A novel geometric approach is presented which enables the reader to reduce the overall size of the Helmholtz assembly without sacrificing any volume in the workspace. Included in the Appendix of this thesis are all of the mechanical …

    colo-mines Repository record for Design, assembly, programming, and testing of triaxially-nested Helmholtz coils, The (opens in a new tab)

  2. Dynamics of a theta pinch discharge in a transverse magnetic field

    … and uniform magnetic bias fields (produced by Helmholtz coils) it was found that the oscillations are suppressed by a flip instability of the plasmoid and the direction of flip is controlled by the transverse magnetic field. Using the suppression of radial hydromagnetic oscillation as the …

    ubc Repository record for Dynamics of a theta pinch discharge in a transverse magnetic field (opens in a new tab) Download PDF for Dynamics of a theta pinch discharge in a transverse magnetic field (opens in a new tab)

  3. Individually-controllable magnetic artificial cilia for microfluidic manipulation tasks

    … use actuation by a rotating field generated by Helmholtz coils or by a rotating permanent magnet. These field sources cannot apply a phase shift to the cilia array and therefore cannot generate a metachronal wave. Nevertheless, magnetic actuation remains desirable for cilia devices as it allows …

    washington Repository record for Individually-controllable magnetic artificial cilia for microfluidic manipulation tasks (opens in a new tab)

  4. Integrated magnetic localization sensing and actuation of steerable robotic catheter for Peripheral Arterial Disease treatment

    … design, feeding mechanism, sensor array, and Helmholtz coils, are detailed. Experimental results using a prototype MSRC demonstrate an average position estimation error of 0.95 mm after calibration. The system successfully navigates vascular phantoms using actuated magnetic steering and …

    texas Repository record for Integrated magnetic localization sensing and actuation of steerable robotic catheter for Peripheral Arterial Disease treatment (opens in a new tab)

  5. Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil

    … experiment. However, only two kinds of detector coils have been typically used in NMR studies. These are the solenoid coil and the Helmholtz coil. The solenoid coil was very popular with the permanent and electromagnet NMR instruments. With the advent of the superconducting magnets the popularity …

    vt Repository record for Zero Quantum Nuclear Magnetic Resonance experiments utilizing a toroid cell and coil (opens in a new tab)

  6. Experiments with laser cooling and cold spinor gases

    … characterization of high current magnetic field coils for a magnetic quadrupole trap (MQT) and Helmholtz coils for future Feshbach spectroscopy are detailed.Second, I describe a series of experiments with spinor gases carried out on the JQI Na spinor apparatus. In the first experiment, I …

    maryland Repository record for Experiments with laser cooling and cold spinor gases (opens in a new tab)

  7. Radiometric measurements of atmospheric temperature

    … and magnetically driven by cross-connected Helmholtz coils. Special electronics are used to maintain a constant amplitude of the piston. Modulating the pressure of the absorbing gas also modifies its absorption coefficient, chopping the centres of spectral lines in the selected band, and …

    oxford Repository record for Radiometric measurements of atmospheric temperature (opens in a new tab)

  8. A miniature 3D-printed Kibble balance for mass sensing applications

    … of a 0.1 T radial magnetic field, anti-Helmholtz coils and opposing permanent magnets, were investigated through computer simulated models and laboratory experiment. The results showed that permanent magnetic material was a viable solution. A “low cost” prototype system at the gram-level …

    soton Download PDF for A miniature 3D-printed Kibble balance for mass sensing applications (opens in a new tab)

  9. Design of Apparatus for a Sterile Neutrino Search Using 131-Cs: the HUNTER Experiment

    … by periodically switching on/off the anti-Helmholtz coils of the magneto-optical trap were studied. The deformation of the spectrometer under its gravity was simulated using Autodesk Inventor.

    temple Repository record for Design of Apparatus for a Sterile Neutrino Search Using 131-Cs: the HUNTER Experiment (opens in a new tab)

  10. Paramagnetic defects in CVD diamonds

    … 2-gap loop-gap resonator and a pair of anti-Helmholtz coils providing a magnetic field gradient <em>∂B<sub>z</sub>/∂z</em>. Using this probe the distribution of N<sup>0</sup><sub>S</sub> was measured in the growth direction of four CVD diamonds to a resolution of 20 μm. The distribution of …

    oxford Repository record for Paramagnetic defects in CVD diamonds (opens in a new tab)

  11. Chip-scale atomic magnetometer

    … the magnetic resonance is not excited by RF coils but by optical modulation of the input laser light: the laser could be modulated in frequency, amplitude (i.e. intensity) or polarization but we adopted the amplitude modulation scheme because it requires the use of only one beam and an …

    strathclyde Repository record for Chip-scale atomic magnetometer (opens in a new tab)

  12. Real time novel observations of net quantum magnetism in macroscopic matter with a nanomagnetic ferrolens and emulation and extrapolation of a spin relativistic electromagnetic flux manifold fiber model for the quantum magnet (electron at rest)

    … like for example, inside electrical solenoids or Helmholtz coils (Helmholtz coil was constructed in our Institution by the thesis author). Another, novel application and published research of the ferrolens the author presents herein, is for the real time display of dynamic (changing) magnetic …

    greece Repository record for Real time novel observations of net quantum magnetism in macroscopic matter with a nanomagnetic ferrolens and emulation and extrapolation of a spin relativistic electromagnetic flux manifold fiber model for the quantum magnet (electron at rest) (opens in a new tab)

  13. A study of the influence of electromagnetic fields on neurite outgrowth in PC12 rat pheochromocytoma cells

    The aim of this project is to study how pulsed and DC electromagnetic fields (EMF) alter the neurite outgrowth in PC12 cells. The percentage of neurite-bearing cells, average neurite length and directivity of neurite outgrowth were analyzed. The influence of pulsed and DC EMF on neurite outgrowth …

    nus Repository record for A study of the influence of electromagnetic fields on neurite outgrowth in PC12 rat pheochromocytoma cells (opens in a new tab) Download file for A study of the influence of electromagnetic fields on neurite outgrowth in PC12 rat pheochromocytoma cells (opens in a new tab)

  14. Měření magnetického pole

    … homogenního magnetického pole pomocí cívek v Helmholtzově uspořádání a návrhem takovýchto cívek.

    brno-tech Repository record for Měření magnetického pole (opens in a new tab)

  15. Homogenní magnetické pole pro spektroskopii s chladnými ionty

    Náplní doktorské práce je návrh a realizace nové experimentální aparatury pro optické iontové hodiny s vysoce stabilním a homogenní magnetickým polem v oblasti zachycených iontů. Hlavním cílem práce je využít poznatky z předchozí generace experimentální sestavy optických iontových hodin a radikálně …