Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"Hemodynamic indices"”.

  1. Computational Fluid Dynamics Modeling of Hemodynamic Changes Induced by Coronary Stenting in Vivo

    … causes marked changes in global and local hemodynamic indices in vivo. Secondly, the in vivo data will be used as input to a computational modeling procedure illustrating how stent geometry causes localized alterations in shear stress.

    marquette Repository record for Computational Fluid Dynamics Modeling of Hemodynamic Changes Induced by Coronary Stenting in Vivo (opens in a new tab)

  2. Numerical modeling of Hemodynamics in the thoracic aorta and alterations by Dacron patch treatment of Aortic Coarctation

    … surgery could lead to local adverse changes in hemodynamic conditions which have been correlated to long term morbidity. No study to date has investigated the local hemodynamics in the human thoracic aorta and the alterations occurring in thoracic aorta of Dacron patients in detail. …

    marquette Repository record for Numerical modeling of Hemodynamics in the thoracic aorta and alterations by Dacron patch treatment of Aortic Coarctation (opens in a new tab)

  3. Hemodynamic mechanisms of experimental and clinical heart failure: a translational perspective

    … characterization of invasive and non-invasive indices of LV function and cardiovascular hemodynamics both in preclinical (Sus scrofa) as well as clinical HF. Following topics were addressed in the current work: 1. The correlation between LV CPO, as clinically relevant index of external LV work, …

    fu-berlin Repository record for Hemodynamic mechanisms of experimental and clinical heart failure: a translational perspective (opens in a new tab)

  4. The impact of spinal cord injury on sympathetic ganglionic control of the heart

    … demonstrated significantly lower cardiac and hemodynamic indices compared to naïve rats. SCGX did not alter these indices in either group, whereas StGX led to a significant decline in cardiovascular function in naïve rats. In T3-SCI animals, responses to StGX were blunted. Comparisons between …

    ubc Repository record for The impact of spinal cord injury on sympathetic ganglionic control of the heart (opens in a new tab) Download PDF for The impact of spinal cord injury on sympathetic ganglionic control of the heart (opens in a new tab)

  5. Effect of Korean Red Ginseng (Panax Ginseng C.A. Meyer) and American Ginseng (Panax Quinquefolius L.) on Blood Pressure Control and Cardiometabolic Risk Factors

    … ginsenoside Rg3-enriched KRG administration on hemodynamic indices in healthy individuals in a pilot randomized controlled trial (RCT) and subsequently 2) the effect of 12-week co-administration of Rg3-enriched KRG and AG intervention on systolic BP (primary outcome) in addition to metabolic …

    toronto-retro Repository record for Effect of Korean Red Ginseng (Panax Ginseng C.A. Meyer) and American Ginseng (Panax Quinquefolius L.) on Blood Pressure Control and Cardiometabolic Risk Factors (opens in a new tab)

  6. Late Complications in the Descending Aorta Following Valve-Sparing Root Replacement (VSRR) in Marfan Syndrome (MFS) Patients: A Computational Analysis

    … native anatomy or the root surgery may alter hemodynamic factors in the DA, potentially predisposing it to dissection. This study uses computational fluid dynamics (CFD) simulations alongside statistical shape modeling (SSM) to investigate the relationships between aortic geometry, hemodynamic …

    toronto-retro Repository record for Late Complications in the Descending Aorta Following Valve-Sparing Root Replacement (VSRR) in Marfan Syndrome (MFS) Patients: A Computational Analysis (opens in a new tab)

  7. Image Based Computational Hemodynamics for Non-Invasive and Patient-Specific Assessment of Arterial Stenosis

    … of arterial stenosis(AS), it cant assess the hemodynamic abnormality caused by an AS. Alternatively, trans-stenotic pressure gradient (TSPG) and fractional flow reserve (FFR) are well-validated hemodynamic indices to assess the ischemic severity of an AS. However, they have significant …

    iupui Repository record for Image Based Computational Hemodynamics for Non-Invasive and Patient-Specific Assessment of Arterial Stenosis (opens in a new tab)

  8. Patient-Specific Modeling of Altered Coronary Artery Hemodynamics to Predict Morbidity in Patients with Anomalous Origin of a Coronary Artery

    … may alter coronary artery blood flow patterns, hemodynamic indices such as time averaged wall shear stress (TAWSS), oscillatory shear index (OSI) and fractional flow reserve (FFR) that impact a patient’s future risk for ischemia and morbidity 2–6 remain largely unexplored. We hypothesized that …

    marquette Repository record for Patient-Specific Modeling of Altered Coronary Artery Hemodynamics to Predict Morbidity in Patients with Anomalous Origin of a Coronary Artery (opens in a new tab)

  9. Noninvasive Imaging of the Immune-Vascular Crosstalk in Head and Neck Cancer

    … imaging (PAI) was employed to measure hemodynamic indices (HbT/sO2) to map and quantify changes in tumor hypoxia during HNSCC progression and in response to immunotherapy. Temporal profiling of tumor hypoxia (sO2) and vascular function (HbT) was performed in orthotopic models of HNSCC, …

    buffalo Repository record for Noninvasive Imaging of the Immune-Vascular Crosstalk in Head and Neck Cancer (opens in a new tab)

  10. Υπολογιστική μελέτη ενδοκρανιακών ανευρυσμάτων

    … the flow of blood but also the calculation of hemodynamic indicators, such as the shear stress whose role is analyzed, which help us in further understanding the development of the disease. Also, in the aforementioned chapter, the stages of modeling are described, which include the …

    greece Repository record for Υπολογιστική μελέτη ενδοκρανιακών ανευρυσμάτων (opens in a new tab)

  11. Αιμοδυναμικές αποκρίσεις και μυϊκή οξυγόνωση κατά τη δυναμική και ισομετρική άσκηση αντιστάσεων ιδίου παραγόμενου έργου

    … The purpose of this thesis was to examine the hemodynamic and muscle oxygenation responses during isometric and dynamic RE under the same workload. METHODS: Twenty-four healthy males (24,8 ± 1 years of age), initially performed isometric bilateral leg press for the assessment of maximal …

    greece Repository record for Αιμοδυναμικές αποκρίσεις και μυϊκή οξυγόνωση κατά τη δυναμική και ισομετρική άσκηση αντιστάσεων ιδίου παραγόμενου έργου (opens in a new tab)

  12. Μη επεμβατική 24ωρη καταγραφή αορτικής πίεσης: συσχέτιση με τη βλάβη οργάνων-στόχου

    … assessment of 24 hour aortic BP, as well as indices of aortic stiffness (pulse wave velocity – PWV) and wave reflections (augmentation index – AI) is now feasible with the use of a brachial-cuff based oscillometric device (Mobil-O-Graph, IEM, Stolberg, Germany). The aim of our study was a) to …

    greece Repository record for Μη επεμβατική 24ωρη καταγραφή αορτικής πίεσης: συσχέτιση με τη βλάβη οργάνων-στόχου (opens in a new tab)

  13. Μελέτη της επίδρασης των μεταβολών της αιμάτωσης των όρχεων στη γονιμοποιητική ικανότητα του κριού

    … at flocks was evaluated. In addition, testicular hemodynamic and echogenicity changes were recorded during a whole year, and the influence of factors affecting testicular vasculature and echotexture (age, season, ejaculation, breeding or non-breeding period) was investigated. Moreover, ram semen …

    greece Repository record for Μελέτη της επίδρασης των μεταβολών της αιμάτωσης των όρχεων στη γονιμοποιητική ικανότητα του κριού (opens in a new tab)