Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"Heterogeneous phantom"”

  1. Measurements of absorbed fractions as a function of source organ size for selected source organs in a heterogeneous phantom

    <p>Measurements of the absorbed fractions have been completed in a representation of an adult human. The primary purpose of this research was to investigate the effect of source organ size on the absorbed fractions in many target organs in the body. For the bladder and the stomach five sizes were …

    ut-knoxville Repository record for Measurements of absorbed fractions as a function of source organ size for selected source organs in a heterogeneous phantom (opens in a new tab)

  2. A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array

    … distributions were studied for two different phantom types: an in-house heterogeneous phantom and a homogeneous phantom. The motivation is to mimic the human anatomy during a lung SBRT treatment and incorporate heterogeneities into the pre-treatment Quality Assurance process, where measured …

    fau Repository record for A dosimetric study of a heterogeneous phantom for lung stereotactic body radiation therapy comparing Monte Carlo and pencil beam calculations to dose distributions measured with a 2-d diode array (opens in a new tab)

  3. X-ray scattering point models for breast cone-beam computed tomography

    … were made using both homogeneous as well as heterogeneous phantoms. The homogeneous phantoms were cylinders, 14 cm and 7 cm in diameter and 10.5 cm in length with various fibroglandular(fib):fat compositions. The hetero- geneous phantom was the 14 cm phantom mentioned previously, but modeled …

    laurentian Repository record for X-ray scattering point models for breast cone-beam computed tomography (opens in a new tab)

  4. Depth doses and photon contamination of electron beams in heterogeneous phantoms

    … and TLD in homogeneous solid water and bone-like phantoms as well as in a solid-water/bone heterogeneous phantom. Our measurement results show that dosimetry based on film and TLD corresponds well with ionization chamber dosimetry in both homogeneous and heterogeneous phantoms if appropriate …

    mcgill Repository record for Depth doses and photon contamination of electron beams in heterogeneous phantoms (opens in a new tab)

  5. Positron Emission Tomography Phantom Studies for Radiation Therapy Target Delineation

    … for cylindrical, spherical, cubic, and geodesic phantoms at various signal to background ratios (SBRs). Phantom studies revealed that as the SBR decreases the required threshold increases. Also, smaller phantom volumes required a larger threshold than larger phantom volumes. Phantom studies …

    wfu Repository record for Positron Emission Tomography Phantom Studies for Radiation Therapy Target Delineation (opens in a new tab)

  6. Toward the Clinical Application of the Prompt Gamma-Ray Timing Method for Range Verification in Proton Therapy

    … be used for the first 2D imaging of a heterogeneous phantom based on prompt gamma-rays. In a last step, a PGT prototype system was designed using the findings from the first two studies. The prototype system is based on a newly developed digital spectrometer and a CeBr3 detector. The …

    qucosa-diss Repository record for Toward the Clinical Application of the Prompt Gamma-Ray Timing Method for Range Verification in Proton Therapy (opens in a new tab)

  7. A Feasible Method to Evaluate RF-Induced Heating Behavior of Passive Orthopedic Implants in Human Body

    … heating in a standard and fully controlled phantom, which is filled with a homogeneous media to mimic the human body tissues. However, the RF-induced heating in a homogeneous regular shaped media is different from that in a heterogeneous human body, especially patients with orthopedic …

    houston Repository record for A Feasible Method to Evaluate RF-Induced Heating Behavior of Passive Orthopedic Implants in Human Body (opens in a new tab)

  8. Phantom Study Incorporating A Diode Array Into The Treatment Planning System For Patient-Specific Quality Assurance

    … quality assurance (QA). Furthermore, a new phantom was studied in which the 2-D array and heterogeneities were incorporated into the patient-specific QA process for lung SBRT. Dual source dual energy computerized tomography (DSCT) and single energy computerized tomography (SECT) were used to …

    fau Repository record for Phantom Study Incorporating A Diode Array Into The Treatment Planning System For Patient-Specific Quality Assurance (opens in a new tab)

  9. Application of a heterogeneous coarse-mesh transport method (COMET) to radiation therapy problems

    … Medical Physics Group here at Georgia Tech, a heterogeneous coarse-mesh transport method (COMET) has been developed for neutron transport to analyze whole-core criticality. COMET decomposes a large, heterogeneous global problem into a set of small fixed source local problems. Response …

    gatech Repository record for Application of a heterogeneous coarse-mesh transport method (COMET) to radiation therapy problems (opens in a new tab)

  10. Advanced Techniques in Magnetic Resonance-Guided High-Intensity Focused Ultrasound

    … on MRI images improved the focus sharpness in heterogeneous phantom simulating conditions of breast tissue. Third, simulated acoustic intensity predicted heating of bones, which enables fast quantitative reduction of bone heating through deactivation of transducer elements in the context of …

    aalto Repository record for Advanced Techniques in Magnetic Resonance-Guided High-Intensity Focused Ultrasound (opens in a new tab)

  11. Método de reconstrução tomográfica de amostras agrícolas com o emprego de técnicas big data

    … of projection matrice of the same plexiglass heterogeneous phantom totalizing 7840 matrice (35.63 GB) which were processed for 12 different configurations totalizing 427.56 GB of processed tomographic data. The cluster configuration was defined after evaluating the Speedup and Efficiency …

    brazil-ufscar Repository record for Método de reconstrução tomográfica de amostras agrícolas com o emprego de técnicas big data (opens in a new tab)

  12. Parallel Radiofrequency Transmission for Safe Magnetic Resonance Imaging of Deep Brain Stimulation Patients at 3 Tesla

    … vary hospital-to-hospital. As a result, standard phantoms, i.e., the ASTM International Standard, used in safety verification experiments may not be suitable for DBS MRI applications. To advance DBS patient safety in MRI, this thesis studied the implant heating effects of pTx system uncertainty, …

    mcmaster Repository record for Parallel Radiofrequency Transmission for Safe Magnetic Resonance Imaging of Deep Brain Stimulation Patients at 3 Tesla (opens in a new tab)

  13. Location and Tracking for Ultra-WideBand In-Body Communications in Medical Applications

    [ES] La cápsula inalámbrica de endoscopia (WCE) es una tecnología notable y atractiva adoptada en el sector biomédico hace varios años. WCE proporciona una tecnología de imagen inalámbrica no invasiva que permite a los especialistas reconocer y diagnosticar enfermedades que afectan todo el tracto …

    upv Repository record for Location and Tracking for Ultra-WideBand In-Body Communications in Medical Applications (opens in a new tab)

  14. Antennas, Wave Propagation, and Localization in Wireless Body Area Networks

    … ITE case was further investigated on realistic heterogeneous phantoms of different age and head sizes. The link loss in the ITE case for an adult heterogeneous phantom was found to be $79$~dB. It was found that the absence of the pinna (outer ear) and the lossless shell under-estimates the link …

    lund Repository record for Antennas, Wave Propagation, and Localization in Wireless Body Area Networks (opens in a new tab)

  15. Caractérisation numérique de l'exposition électromagnétique des personnes en bandes HF et VHF

    Dans les environnements militaires, et plus particulièrement dans le domaine terrestre, de nombreux systèmes radioélectriques HF (de 3 à 30 MHz), VHF (de 30 à 300 MHz) et UHF (de 300 à 3000 MHz) sont utilisés. Ces systèmes remplissent plusieurs fonctions (communication longue et courte distance, …

    star-france Repository record for Caractérisation numérique de l'exposition électromagnétique des personnes en bandes HF et VHF (opens in a new tab)