Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"Heterotrophic Plate Counts"”.
-
The Presence of Heterotrophic Plate Counts in South Dakota Water Distribution Systems and Their Correlation with System Characteristics
… not a regulatory enumeration method, bulk water heterotrophic plate counts (HPC) can give insight into the bacterial quality of distributed drinking water. In addition, elevated levels of heterotrophic plate counts are often associated with aesthetic deterioration, nitrification episodes, …
-
Microbial biofilms in dental unit water lines
… effect of plating and incubation conditions on heterotrophic plate counts and 3) evaluate the effectiveness of marketed products in reducing microbial counts in water used for nonsurgical and surgical dental procedures. Over a 12 week period, water samples were collected weekly from the …
-
Analysis and control of biofilms in a model drinking water system
… analysis methods, including biofilm sampling, heterotrophic plate counts, total carbohydrates content test, epifluoresence microscopy (LIVE/DEAD kit), and scanning electron microscopy , were adopted and modified. The biofilm control abilities of three different chlorine based agents (free …
-
The effect of biostimulation on geochemical and microbiological conditions in an isolated dolostone fracture
… electron acceptors, biochemical oxygen demand, heterotrophic plate counts, and microbial diversity were evaluated before and after the experiment. Monitoring results for the withdrawal well confirmed that nutrient delivery was occurring, albeit with substantial mass loss due to incomplete flow …
-
Survival of enterococcal and streptococcal species in natural waters
… at 25°C, and decline was measured by heterotrophic plate counts at specific time intervals. Results of survival studies using ATCC derived species showed that the Wash could sustain microbial viability over extended periods of time, with the longest-lived species, E. faecium, surviving …
-
Assessment and Reduction of Microbial Risks in Emergency Eyewash Stations
… of exposure to microbial contaminants, including Heterotrophic Plate Counts (HPC), Legionella pneumophila, and non-tuberculosis Mycobacterium. The results indicate that irregularly flushed eyewash stations showed a higher rate of unsafe microbial counts compared to those with regular flushing and …
-
Water Quality Variations During Nitrification In Drinking Water Distribution Systems
… chloramines residual, dissolved oxygen, heterotrophic plate counts (HPCs), pH, alkalinity, and nitrogen species were monitored and found to vary as expected by stoichiometry associated with theoretical biological reactions excepting alkalinity. Nitrification was confirmed in the PDSs. The …
-
Studies on the survival and viability testing of Cryptosporidium parvum oocysts in the water environment.
… excystation assay combined with total oocyst counts; bacterial heterotrophic plate counts (HPC) at the start of each experiment were determined on R2A agar and counted after 5 days of incubation at room temperature. All water samples were sent to a commercial laboratory for chemical analysis. …
-
Modelling water quality for water distribution systems
… thesis concentrates on disinfectant and particle counts as two important indicators of water quality. The models discussed in this work are based on data collected by the author. The experimental set-up and procedure are described and observations of particle counts, particle counter size …
-
A study of the bacteriological quality of bottled and tap water in Cebu City, Philippines : a thesis presented in partial fulfilment of the requirements for the degree of Master of Environmental Management at Massey University, Manawatu, New Zealand
… thermotolerant coliforms, total coliforms, and heterotrophic plate counts. In addition, sanitation programs applied by bottled water manufacturers and the local water system supplier were surveyed by means of a questionnaire. The study focussed on bottled water brands with the greatest combined …
-
The Effects of Mesquite Tree Removal on Soil Microbial and Nutrient Cycling Processes in Semi-Arid Environments
… total soil C and N, microbial biomass C and N, heterotrophic plate counts, and CO2 and N2O fluxes were found between treatments on different dates throughout the experiment. Despite this finding of some significant differences between treatments for some parameters measured, no recognizable …
-
Rainwater harvesting : the impact of residential-scale treatment and physicochemical conditions in the cistern on microbiological water quality
… was positively rank-correlated with heterotrophic plate counts (HPC) and L. pneumophila in non-chlorinated cisterns. The harvested rainwater microbiome was diverse and distinct between RWH sites. The diversity of the rainwater microbiome was correlated with HPC and DOC concentrations. …
-
Linkage Between Characteristics of Premise Plumbing Systems and Microbial Quality of Stagnant Drinking Water
… Free chlorine concentrations were also linked to heterotrophic plate counts. Additionally, the effect of pipe size on free chlorine concentration after overnight stagnation was analyzed. These results were used to show flushing tap water for 15s for every 100ft of 0.5in copper piping in order to …
-
Comparing the distribution of pathogenic bacteria and common indicator microorganisms in biofilms on different surface types in an agricultural watershed in British Columbia (Canada)
… the presence of faecal contamination indicators (heterotrophic plate counts, faecal coliforms, enterococci, and E. coli) and particular pathogens (E. coli 0157, Campylobacter sp. and Salmonella sp.) in water, sediment, and in biofilms on river and slate rock, wood, sandpaper, and Lexan™ in Elk …
-
Effects of transgenic hybrid aspen over-expressing polyphenol oxidase on the diversity of rhizosphere bacteria and fungi
… oxidase gene on rhizosphere communities. Heterotrophic plate counts and cultivation-independent methods were used to compare bacterial and fungal populations associated with transgenic PPO over-expressing and unmodified control trees. Total community DNA extracted from rhizosphere soils …
-
Multiple Approaches to the Restoration of Disturbed Desert Land
… communities within mine tailings by bacterial counts and bacterial diversity. The diversity of neutral copper mine tailings two weeks after biosolid application was compared with that of desert soil via cloning and sequencing of PCR amplified community 16S rRNA. Culturable heterotrophic plate …
-
Molecular toolbox for the monitoring and control of water distribution biofilms
… (FISH). Conventional methods such as heterotrophic plate counts were also included. Results show that chlorine does not eradicate bacteria by the proportions generally reported using culture-reliant methods. Within both drinking and recycled water distribution systems, bacteria …
-
Fate of polycyclic aromatic hydrocarbons in plant-soil systems : plant responses to a chemical stress in the root zone
… in soil. In addition, soil respiration and heterotrophic plate counts of rhizosphere microorganisms increased in plants exposed to phenanthrene as compared to controls.</p> <p>This study demonstrates the Importance of the root-soil interface for plants growing in PAH contaminated soil and …
-
The effect of biofilm on THM formation in chlorinated drinking water of a PVC pipe distribution system
… of THM precursors from the bulk water phase. Heterotrophic plate counts (HPCs) carried out on biofilm scrapings from the pipe surfaces revealed that exposure to chlorine stress could lead to bacterial inactivation or biofilm regrowth. Under stress, biofilm bacteria can take advantage of some …
-
Organic Carbon Generation Mechanisms in Main and Premise Distribution Systems
… generation of organic carbon and either heterotrophic plate counts (HPC) or of bacterial 16S rRNA genes. DSD-BDOC was also explored in a simulated distribution system with two disinfectant types (chlorine and chloramine) and three pipe materials (PVC, cement, and iron). TOC increased with …
Page 1 of 2