Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 7 of 7 for “"HiFRUS"”.
-
Receiver Channel Recovery in High-Frame-Rate Ultrasound Imaging using Branched Convolutional Neural Networks
High frame rate ultrasound (HiFRUS) is an imaging paradigm that utilizes unfocused transmissions to perform acquisitions at kilohertz frame rates, and its high temporal resolution enables its use in tracking dynamic physiological events. Integration of HiFRUS techniques into compact ultrasound …
-
Pressure Wave Velocity Using High-Frame-Rate Ultrasound Imaging for Urodynamic Study
… and bladder stones. High-frame-rate ultrasound (HiFRUS) has enabled significant advances in urology through visualization of high temporal urinary flow dynamics within the male urinary tract during voiding. Such work has shown that characteristic flow patterns for pathological states found within …
-
Aliasing-Free Maximum Velocity Estimation using Multi-angle Plane Wave Vector Flow Imaging
… source of error. High-frame rate ultrasound (HIFRUS) is a novel imaging modality that insonifies the entire ultrasound region simultaneously and is capable of capture flow velocities at thousands of frames per second. Instead of a small sample volume that measures maximum velocity biomarkers …
-
Ultrasound Imaging Innovations for Visualization and Quantification of Vascular Biomarkers
… is the use of high frame rate ultrasound (HiFRUS) imaging principles to track hemodynamic events at fine temporal resolution (through using frame rates of greater than 1000 frames per second). The existence of turbulent flow and intra-plaque microvessels, as well as anomalous blood flow …
-
High-Frame-Rate Ultrasound Characterization of Carotid Pulse Waves to Assess Cerebrovascular Resistance
… developed based on high-frame-rate ultrasound (HiFRUS) paradigm with frame rate up to 10k frame per second. HiFRUS enables the estimation of blood flow velocity and the capture of transient pressure dynamics in the carotid artery where conventional ultrasound cannot achieve. To realize the …
-
Robust Flow Component Identification for Blockwise SVD Clutter Filtering in High-Frame-Rate Ultrasound Using a Deeply Connected Neural Network
… types of filters in high-frame-rate ultrasound (HiFRUS) making use of both temporal and spatial information use the singular value decomposition (SVD) have been proposed. These filters function by decomposing the input signal into a series of orthonormal basis vectors or components. In theory, as …
-
High-Frame-Rate Ultrasound Imaging Innovations for Complex Flow Quantification
Vascular pathology such as atherosclerosis or arterial stiffening involves significant disruption in the blood flow dynamics found in the vasculature, with complex behavior such as jets and swirling typically seen in diseased vessels. Detecting and mapping complex blood flow dynamics in the human …