Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 79 for “"High Frequency Ultrasound"”

  1. High-Frequency Ultrasound Drug Delivery and Cavitation

    … of polymeric micelles and triggers release by ultrasound application was investigated at an applied frequency of 500 kHz. The investigation also included elucidating the mechanism of drug release at 70 kHz, a frequency which had previously been shown to induce drug release. A fluorescence …

    byu Repository record for High-Frequency Ultrasound Drug Delivery and Cavitation (opens in a new tab)

  2. Nonlinear Wave Propagation in High Frequency Ultrasound Imaging

    The existing safety standards for diagnostic ultrasound devices were developed for low frequency systems (1 to 10 MHz) under the assumption that nonlinear effects are negligible. However, the standards are now being used for relatively high frequency systems (up to 70 MHz); nonlinear effects are …

    toronto-retro Repository record for Nonlinear Wave Propagation in High Frequency Ultrasound Imaging (opens in a new tab)

  3. High-frequency ultrasound backscatter analysis of hyaline cartilage

    High-frequency ultrasound is a promising method to characterize osteoarthritic changes of cartilage tissue in vivo. Numerous studies have investigated the cartilage surface reflection and successfully related derived ultrasound surface parameters to the degeneration stage of cartilage. Only a few …

    fu-berlin Repository record for High-frequency ultrasound backscatter analysis of hyaline cartilage (opens in a new tab)

  4. The Response of Individual Microbubbles to High Frequency Ultrasound

    … majority of studies investigating the physics of ultrasound-triggered microbubble behaviour have been conducted at low frequencies (<5 MHz), motivated by imaging applications for the heart, liver and pancreas. There is gaining interest, however, in employing contrast imaging strategies to higher …

    toronto-retro Repository record for The Response of Individual Microbubbles to High Frequency Ultrasound (opens in a new tab)

  5. Quantification of Ultrasound Contrast Agents Using High-Frequency Ultrasound

    Ultrasound contrast agents (UCAs) are small microbubbles filled with gas. Because of their scattering properties, UCAs enhance the diagnostic capabilities of ultrasonic imaging. UCAs are associated with therapeutic or enhancing therapeutic applications of ultrasound and with possible adverse …

    uiuc Repository record for Quantification of Ultrasound Contrast Agents Using High-Frequency Ultrasound (opens in a new tab)

  6. High Frequency Ultrasound RF Time Series Analysis for Tissue Characterization

    Ultrasound-based tissue characterization has been an active field of cancer detection in the past decades. The main concept behind various techniques is that the returning ultrasound echoes carry tissue-dependent information that can be used to distinguish tissue types. Recently, a new paradigm for …

    queens Repository record for High Frequency Ultrasound RF Time Series Analysis for Tissue Characterization (opens in a new tab)

  7. CMUT array design and fabrication for high frequency ultrasound imaging

    High frequency ultrasound imaging is utilized in a broad range of applications from intravascular imaging to small animal imaging for preclinical studies. Capacitive micromachined ultrasonic transducers (CMUTs) possess multiple preferable characteristics for high frequency imaging systems, such as …

    gatech Repository record for CMUT array design and fabrication for high frequency ultrasound imaging (opens in a new tab)

  8. Miniature high-frequency ultrasound transducers for magnetic soft continuum robot applications

    Intracorporeal high-frequency ultrasound (US) is a potentially important modality in modern medical diagnostics, offering superior resolution for internal anatomical structures. However, conventional delivery platforms, such as needles, catheters and capsules, are often constrained by their …

    glasgow Repository record for Miniature high-frequency ultrasound transducers for magnetic soft continuum robot applications (opens in a new tab)

  9. Accuracy of High-Frequency Ultrasound in the Detection of White Spot Lesions

    … this study was 1) to determine the accuracy of ultrasound (US) by comparing repeated depth measurements of white spot lesions (WSL) with those of a gold standard of micro-CT (μ-CT) and 2) to assess the bias of the US measurements. Materials and Methods: This in-vitro study included 120 bovine …

    buffalo Repository record for Accuracy of High-Frequency Ultrasound in the Detection of White Spot Lesions (opens in a new tab)

  10. Estimation of a Coronary Vessel Wall Deformation with High-Frequency Ultrasound Elastography

    … fields depend on the resolution level of the ultrasound image and to date best resolution levels obtained in the literature are not enough to clearly see all boundaries of the artery, one of the main goals is to acquire high-resolution coronary vessel wall ultrasound images at different …

    gatech Repository record for Estimation of a Coronary Vessel Wall Deformation with High-Frequency Ultrasound Elastography (opens in a new tab)

  11. Characteristics of blood vessel wall and atherosclerosis using high frequency ultrasound signals

    … many techniques like electrocardiogram, x-rays, ultrasound, electroencephalogram, computed tomography and magnetic resonance imaging use signal and image processing techniques to determine the physical and biological properties of the tissues and organs. The underlying principle in signal …

    iastate Repository record for Characteristics of blood vessel wall and atherosclerosis using high frequency ultrasound signals (opens in a new tab)

  12. Optical micromachined ultrasound transducers (OMUT) : a new approach for high frequency ultrasound imaging

    … technology is the backbone of most medical ultrasound imaging arrays, however, in scaling the technology to sizes required for high frequency operation (> 20 MHz), it encounters substantial difficulties in fabrication and signal transduction efficiency. These limitations particularly affect …

    umn Repository record for Optical micromachined ultrasound transducers (OMUT) : a new approach for high frequency ultrasound imaging (opens in a new tab)

  13. Investigation of high-frequency ultrasound biomicroscopy for examining arteriopathy in hand transplant patients.

    … and measurements of brachial indices via ultrasound, did not indicate that the patient was in such a severe condition in the days prior to amputation. Histological analysis of tissue from the amputated graft revealed massive intimal hyperplasia, a hallmark of chronic rejection. The purpose …

    louisville Repository record for Investigation of high-frequency ultrasound biomicroscopy for examining arteriopathy in hand transplant patients. (opens in a new tab)

  14. Listening to bio-engineered tissues and materials: Assessing cellularity and stiffness using high-frequency ultrasound

    … of long-term monitoring. In this thesis, an ultrasound imaging method is developed to evaluate the acoustic and mechanical properties of engineered tissues and biomaterials to address these analytical tool gaps. This high-frequency ultrasound technique is non-destructive, non-invasive, and …

    toronto-retro Repository record for Listening to bio-engineered tissues and materials: Assessing cellularity and stiffness using high-frequency ultrasound (opens in a new tab)

  15. Process Development And Characterization Of Piezoelectric Transducers On Flexible Substrates For High Frequency Ultrasound Applications

    … commonly used type of piezoelectric, but their high sintering temperature and rigidity are limiting factors for their use in some applications especially one that require conformal structures on flexible and non-planar surfaces. This thesis focuses on characterization and process development for …

    gatech Repository record for Process Development And Characterization Of Piezoelectric Transducers On Flexible Substrates For High Frequency Ultrasound Applications (opens in a new tab)

  16. Fabrication of lead free and lead based 1-3 piezoelectric composites for high frequency ultrasound transducers

    … free piezocomposites and transducers for use in high frequency medical ultrasound imaging applications. A water based gel casting and micro moulding approach has been developed to fabricate 1-3 composites with a random pillar structure in the lead free and lead based piezoelectric material. High …

    birmingham Repository record for Fabrication of lead free and lead based 1-3 piezoelectric composites for high frequency ultrasound transducers (opens in a new tab)

  17. High-Performance CMOS Front-End ASICs for SiPM Detectors and High-Frequency Ultrasound and Photoacoustic Imaging

    Silicon photomultiplier (SiPM), as a high sensitivity photon detector, has been widely used in high energy physics, positron emission tomography imaging, and light detection and ranging applications. The slow-rising edge of standard SiPM signal, however, makes the timing measurement sensitive to …

    houston Repository record for High-Performance CMOS Front-End ASICs for SiPM Detectors and High-Frequency Ultrasound and Photoacoustic Imaging (opens in a new tab)

  18. Development of forward-viewing high-frequency ultrasound techniques for velocity and wall shear stress estimation in coronary arteries

    … with plaque formation and remodeling, while high WSS is associated with plaque vulnerability. Because the spatial distribution of WSS varies with flow conditions and with vascular anatomy, accurate estimation of local hemodynamics and local WSS distribution in coronary arteries could be used …

    gatech Repository record for Development of forward-viewing high-frequency ultrasound techniques for velocity and wall shear stress estimation in coronary arteries (opens in a new tab)

Page 1 of 4