Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 40 for “"High Resolution peripheral Quantitative Computed Tomography (HR-pQCT)"”

  1. Effect of Vitamin D and Whole Body Vibration on High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) Parameters of the Distal Tibia

    … bone density of the distal tibia as measured by HRpQCT. The study consisted of four parallel groups of equal numbers (40 in total); WBV and placebo group, placebo group, vitamin D group and vitamin D+ WBV group. Measurements (HR-pQCT, serum 25 (OH)D, PTH, bone profile) were collected at baseline …

    whiterose Repository record for Effect of Vitamin D and Whole Body Vibration on High Resolution peripheral Quantitative Computed Tomography (HR-pQCT) Parameters of the Distal Tibia (opens in a new tab)

  2. Differences in Bone and Cartilage Between Women with Anterior Cruciate Ligament Tears and Healthy Controls

    … (ACL) tears increase the risk of osteoarthritis (OA) leading to degradation of cartilage and bone. While the contribution of bone in OA development is unclear, evidence suggests that bone changes accompany cartilage degradation. This study aims to explore the relationship between …

    calgary Repository record for Differences in Bone and Cartilage Between Women with Anterior Cruciate Ligament Tears and Healthy Controls (opens in a new tab)

  3. Cortical Porosity in Bone

    … CtPo in the appendicular skeleton in vivo through the use of high-resolution peripheral quantitative computed tomography (HR-pQCT). There are two approaches to assessing CtPo from HR-pQCT imaging data based on a threshold-based or a density-based approach. The performance of both methods was …

    calgary Repository record for Cortical Porosity in Bone (opens in a new tab)

  4. Impact of Growth Hormone on Adult Bone Quality in Turner Syndrome - A High Resolution Peripheral Quantitative Computed Tomography Study

    … Turner Syndrome (TS) is the most common chromosomal disorder in females. Commonly associated features include short stature, ovarian failure and osteoporosis in adult years. Childhood short-stature in TS is commonly treated with growth hormone (GH). This historic cohort-study using dual …

    calgary Repository record for Impact of Growth Hormone on Adult Bone Quality in Turner Syndrome - A High Resolution Peripheral Quantitative Computed Tomography Study (opens in a new tab)

  5. Using finite element models under multiple loading conditions to improve the association between radius and tibia microarchitecture and prevalent osteoporotic vertebral fracture

    … at the tibia and radius, measurable by high-resolution peripheral quantitative computed tomography (HR-pQCT) exist between individuals with a prevalent vertebral fracture and healthy controls. As fracture is a result of mechanical failure, FE models of these sites in physiologically …

    calgary Repository record for Using finite element models under multiple loading conditions to improve the association between radius and tibia microarchitecture and prevalent osteoporotic vertebral fracture (opens in a new tab)

  6. A study of bone quality in femoral neck of osteoarthritis

    Osteoarthritis (OA) is the most common joint disease and skeletal disorder related to aging. Hip OA is a common chronic degenerative joint disorder that causes pain, stiffness and physical disability in the elderly population. The cause of this disease is still unclear. However, it is estimated …

    ubc Repository record for A study of bone quality in femoral neck of osteoarthritis (opens in a new tab)

  7. Investigation of Toe Tip Necrosis Syndrome in Feedlot Cattle using Biomechanical Testing and Imaging

    … line separation. Specimens were imaged using a High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT) scanner with a contrast agent to assess the volume of separation. Objective 2 investigated whether mechanical damage under a fatigue loading regime would induce white line …

    sask Repository record for Investigation of Toe Tip Necrosis Syndrome in Feedlot Cattle using Biomechanical Testing and Imaging (opens in a new tab)

  8. Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling

    … using finite element (FE) models generated from high-resolution peripheral quantitative computed tomography (HR-pQCT) images; however, these models are limited because they determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an …

    sask Repository record for Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling (opens in a new tab)

  9. Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling

    … using finite element (FE) models generated from high-resolution peripheral quantitative computed tomography (HR-pQCT) images; however, these models are limited because they determine failure load under pure compressive loading conditions and neglect off-axis loads that occur during a fall on an …

    sask Repository record for Predicting off-axis bone strength of the distal radius using high-resolution peripheral quantitative computed tomography based finite element modeling (opens in a new tab)

  10. Investigating Bone Remodelling in Knee Osteoarthritis using HR-pQCT Imaging

    Osteoarthritis (OA) is the most common type of arthritis and a significant cause of disability worldwide. With an aging population in Canada, the prevalence and burden of OA is expected to increase. Knee OA is the most common form of OA, comprising upwards of 30% of cases. Early-stage OA can be …

    calgary Repository record for Investigating Bone Remodelling in Knee Osteoarthritis using HR-pQCT Imaging (opens in a new tab)

  11. Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method

    Three-dimensional (3D) imaging with high-resolution peripheral quantitative computed tomography (HR-pQCT) and micro-finite element (FE) analysis provides important insight into bone health. Longitudinal analyses of bone morphology maximize precision by using 2D slice-matching registration (SM) or …

    calgary Repository record for Enhanced Longitudinal Analysis of Bone Strength Estimated by 3D Bone Imaging and the Finite Element Method (opens in a new tab)

  12. Non-invasive Diagnostic Tests for Renal Osteodystrophy

    Chronic Kidney Disease – Mineral Bone Disorder (CKD-MBD) is a common complication of advanced chronic kidney disease (CKD). Bone abnormalities of CKD-MBD are known as renal osteodystrophy (ROD) and are characterised by abnormal bone turnover and mineralization. ROD results in bone microstructural …

    whiterose Repository record for Non-invasive Diagnostic Tests for Renal Osteodystrophy (opens in a new tab)

  13. Mri-Based Assessment Of Cortical Bone Matrix And Mineral Properties In A Clinical Setting

    … density, porosity and mineral density, to be quantitatively imaged with either 1H or 31P ultra-short TE (UTE) or zero TE (ZTE) sequence. In this dissertation, an integrated MRI protocol measuring both bone matrix and mineral properties in vivo was first designed and tested with clinical …

    penn Repository record for Mri-Based Assessment Of Cortical Bone Matrix And Mineral Properties In A Clinical Setting (opens in a new tab)

  14. Spectrum of Microarchitectural Bone Disease in Inborn Errors of Metabolism

    … in a wide range of IBEM disorders using new three-dimensional technology, high-resolution peripheral quantitative computed tomography (HR- pQCT). Moreover, bone strength was estimated by employing finite element techniques on HR- pQCT image data. A further examination of these measurements in …

    calgary Repository record for Spectrum of Microarchitectural Bone Disease in Inborn Errors of Metabolism (opens in a new tab)

  15. Development of Novel Automated Methods for Quantitative Analysis of Bone with High-Resolution Peripheral Computed Tomography and Application to Investigate Bone Changes Following ACL Injury

    Knee osteoarthritis (OA) is a prolific and devastating disease. The processes leading to the development of OA are poorly understood, but periarticular bone adaptations are theorized to play an important role. High-resolution peripheral quantitative computed tomography (HR-pQCT) can resolve human …

    calgary Repository record for Development of Novel Automated Methods for Quantitative Analysis of Bone with High-Resolution Peripheral Computed Tomography and Application to Investigate Bone Changes Following ACL Injury (opens in a new tab)

  16. Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis

    Rheumatoid arthritis (RA) is a chronic inflammatory disease characterized by bone erosions, which serve as critical indicators of disease progression and structural damage. High-resolution peripheral quantitative computed tomography (HR-pQCT) is the reference standard for imaging these erosions but …

    calgary Repository record for Super-Resolution of Cone Beam Computed Tomography: Applications in Bone Analysis for Rheumatoid Arthritis (opens in a new tab)

  17. An Inverse Interface Evolution Problem to Identify Participant-Specific Bone Microarchitecture Adaptation

    … microarchitecture, strength and density change throughout our lifetime through the natural process of bone adaptation. With age, the mechanisms that normally maintain bone’s mechanical competence are disrupted and rapid bone loss ensues. In an attempt to understand these mechanisms, many theories …

    calgary Repository record for An Inverse Interface Evolution Problem to Identify Participant-Specific Bone Microarchitecture Adaptation (opens in a new tab)

  18. Using High Resolution Peripheral Quantitative Computed Tomography to Evaluate Bone Health and Relative Energy Deficiency in Sport Risk in Elite Winter Sport Athletes

    … hip or spine by dual X-ray absorptiometry (DXA). High-resolution peripheral quantitative computed tomography (HR-pQCT) measures volumetric BMD (vBMD), microarchitecture, geometry, and estimated strength reported as failure load. The objective of this study was to assess the differences in bone …

    calgary Repository record for Using High Resolution Peripheral Quantitative Computed Tomography to Evaluate Bone Health and Relative Energy Deficiency in Sport Risk in Elite Winter Sport Athletes (opens in a new tab)

  19. Using HR-pQCT and finite element analysis to inform clinical assessment of distal radius fractures

    … DRF. Finite element (FE) modelling coupled with high-resolution peripheral quantitative computed tomography (HR-pQCT) allows for non-invasive in vivo assessment of bone density and stiffness throughout the fracture healing process, which may inform fracture healing progression and cast removal. …

    calgary Repository record for Using HR-pQCT and finite element analysis to inform clinical assessment of distal radius fractures (opens in a new tab)

  20. Évaluation in vivo chez l'enfant du comportement mécanique du thorax et des propriétés mécaniques des côtes

    … Osseuse (DMO) mesurée par la tomodensitométrie quantitative (Quantitative Computed Tomography, QCT) et la tomographie périphérique quantitative à haute résolution (High Resolution Peripheral Quantitative Computed Tomography, HR-pQCT). La DMO peut être mesurée par QCT in vivo. Ensuite, les …

    star-france Repository record for Évaluation in vivo chez l'enfant du comportement mécanique du thorax et des propriétés mécaniques des côtes (opens in a new tab)

Page 1 of 2