Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 30 for “"High frequency signal injection"”
-
A high-frequency signal injection based sensorless drive method for brushless DC motor
<p>Inductance saliency is a rotor position self-sensing method that complements traditional self-sensing methods and is believed to be able to deliver robust closed-loop control under different conditions in low-speed to standstill situations. In this paper, a novel rotor position self-sensing …
-
Control and supervision of permanent magnet synchronous machines using high frequency signal injection
… BEMF based methods and methods based on the injection of some form of test signal into the stator terminal of the machine. Thermal models require previous knowledge of the machine geometry, materials and cooling system, making the model specific for each machine design. BEMF based methods …
-
Shaft transducerless vector control of the interior permanent magnet motor with speed and position estimation using high frequency signal injection and flux observer methods
… and position estimation using saliency based high frequency signal injection and fundamental model based flux observer methods will be investigated. The magnetic saliency characteristic of a 2.2-kW IPM motor will be experimentally extracted by means of high frequency signal injection. High …
-
Sensorless Control of Switched-Flux Permanent Magnet Machines
… permanent magnet (SFPM) machines, based on high-frequency signal injection methods for low speed and standstill and the back-EMF based methods for medium and high speeds.
-
An adaptive observer with signal injection for interior permanent magnet synchronous motors
… estimation methods are proposed. In the methods, high-frequency signal injection is used for stabilizing a modified voltage model and an adaptive observer at low speeds. The hybrid methods allow sustained operation at low speeds, yet preserve good dynamic properties. For the adaptive observer, an …
-
Control of a Permanent Magnet Synchronous Motor with Non-Sinusoidal Flux Density Distribution
… to estimate the rotor position, based on high frequency signal injection and a non linear observer, is also implemented with good results. The flux linkage harmonics are measured and the predicted torque and current ripple are verified by measurements.
-
Controllo sensorless di motori sincroni a riluttanza alimentati tramite VSI e matrix converter
… motors, synchronous reluctance drives pose higher efficiency due to the absence of rotor cage losses. In comparison with permanent magnet motors, SyR motors are cost effective solutions since there is no magnet on their rotor's structures. If field orientation control approach is adopted for …
-
Injeção de sinais de alta frequência para o diagnóstico de falhas no estator de um PMSM de seis fases
… main contribution lies in the identification of highly incipient inter-turn short circuits — involving only two turns — even at very low speeds (15 rpm), a condition where most conventional methods lose sensitivity or fail.A mathematical model of the faulty machine under high-frequency signal …
-
A New High-Frequency Injection Method for Sensorless Control of Doubly-Fed Induction Machines
… Machine (DFIM). The proposed method is based on high-frequency signal injection and the fact that the rotor of a DFIM can be seen as a rotating secondary of an induction transformer. </p><p>The currently used sensorless techniques, besides being parameter sensitive, fail during fault ride-through …
-
Sensorless Rotor Position Estimation For Brushless DC Motors
… sensorless approaches, Back-EMF measurement and high frequency signal injection is the most common. Back-EMF is an electromotive force, directly proportional to the speed of rotor revolutions per second, the greater the speed motor acquires the greater the Back-EMF amplitude appears against the …
-
Multi-objective design, optimization, and condition monitoring of high-performance electric machines for electric propulsion
… electric propulsion. In particular, the selected high-performance electric machines are the switched reluctance machine (SRM) with a simple and robust structure, and the interior permanent magnet (IPM) machine with a high torque density and efficiency. For SRMs, an active current profiling …
-
Model-Based Position Estimation for Synchronous Reluctance Motor Drives
… stability of the observers is studied via small-signal linearization under erroneous model parameters. Based on the analysis, robust gain selections are proposed with maximal tolerance for model parameter uncertainties. For improved performance, the observers are augmented with parameter …
-
Rotor resistance estimation ASM
… rotor resistance. The second method relied on high frequency signal injection (HFSI), which affects the commanded reference torque, allowing for the estimation of the rotor resistance. The simulation results obtained using MRAS and HFSI demonstrated successful estimation of the rotor resistance …
-
Microgrid Operation - Islanding Detection, Islanded Operation, Re-connection and Energy Storage System
… ability of islanded operation would lead to the high reliability of electric power supply. Furthermore, microgrid could cut down the distance between the power generation and local loads, resulting in decreasing the cost of electric power transmission. This thesis focuses on the reliable …
-
New Sensorless Permanent Magnet Synchronous Motor Drive
… operations. Among these techniques, pulsating high-frequency signal injection (PHFSI) stands out as a commonly used technique in various industrial applications. However, a significant limitation arises when applying the PHFSI technique in surface PMSMs (SPMSMs) due to the absence of magnetic …
-
On SPMSM rotor position estimation from standstill and for low speeds - Evaluation of techniques for estimating position and speed of an SPMSM
… position estimation schemes were conducted. A signal injection technique was compared with the statically compensated voltage model (SCVM) due to difficulties in incorporating more suitable choices and also due to time constraints. A simple magnetic pole identification method was implemented …
-
Sensorless direct torque and flux control of interior permanent magnet synchronous motors at very low speeds including standstill
… clearly indicate the potential of a high-performance direct torque controlled IPM synchronous motor drive without a mechanical encoder. The DTC technique and its associated problems have been further investigated in this thesis. Its major drawback namely the high torque and flux …
-
CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES WITH SMALL DC-LINK CAPACITOR
… the influence of dc-link voltage fluctuation on high-speed sensorless control methods, particularly the extended electromotive force (EEMF)-based method. The results indicate that the dc-link voltage fluctuation can induce the harmonics in the estimated rotor position error, and deteriorate the …
-
Control of current harmonics in dual three-phase permanent magnet synchronous machine systems
… (PMSMs), dual three-phase (DTP) PMSMs exhibit higher power rating, power/torque sharing capability, and fault-tolerant capability, as well as lower torque ripples. They also maintain the merits of PMSMs, i.e. high power density, high torque density, and high efficiency. However, the major …
-
Sensorless torque and rotor position control for interior permanent magnet machines at standstill and low speed
… estimation method is firstly proposed based on high frequency rotating voltage injection. Compared to conventional methods, the proposed method can detect the initial rotor position faster by comparing the three phase high frequency current amplitudes as a result of high frequency rotating …
Page 1 of 2