Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"High voltage apparatus"”

  1. Computer based on-line diagnostics of insulation quality of high voltage apparatus

    … directly related to the insulation condition of high voltage apparatus in service, which may age and deteriorate under normal operating conditions. Therefore, the detection of insulation quality of high voltage apparatus is important. This task can be implemented advantageously by the measurement …

    manitoba Repository record for Computer based on-line diagnostics of insulation quality of high voltage apparatus (opens in a new tab)

  2. Digital technique for on-line measurement of dissipation factor of high voltage apparatus

    … to periodically monitor the condition of power apparatus. Conventionally this may be achieved by carrying out tests such as the partial discharge and dissipation factor tests in a laboratory. This method, however, requires that the apparatus in question be disconnected from service and …

    manitoba Repository record for Digital technique for on-line measurement of dissipation factor of high voltage apparatus (opens in a new tab)

  3. Wireless passive substrate-integrated waveguide (SIW) resonator-based e-field sensor and its application to monitor high-voltage apparatus

    … in the measurement of electric field of high voltage produced by two parallel plates. The proposed sensor is potentially applicable to measure the electric field of the high voltage apparatus remotely. When exposed to an external electric field, the resonance frequency of the SIW …

    manitoba Repository record for Wireless passive substrate-integrated waveguide (SIW) resonator-based e-field sensor and its application to monitor high-voltage apparatus (opens in a new tab)

  4. Passive wireless resonator sensor for the measurement of AC electric field

    … of AC electric field in the vicinity of high voltage apparatus. This sensor is applicable in remote condition monitoring of high voltage apparatus where close distance measurements raises safety hazards for operators. The sensor is designed using a coaxial cavity resonator structure (in …

    manitoba Repository record for Passive wireless resonator sensor for the measurement of AC electric field (opens in a new tab)

  5. Experimental studies of breakdown characteristics of SF|6/CF|4 mixtures in highly non-uniform fields for high-voltage applications

    … at increased pressure range of the practical high-voltage gas-insulated switchgears (3.0-5.0 bar). The use of SF$\sb6$/CF$\sb4$ mixtures with lower condensation temperature and comparable dielectric properties, is proposed to overcome the SF$\sb6$ limitations for operation in extreme cold …

    manitoba Repository record for Experimental studies of breakdown characteristics of SF|6/CF|4 mixtures in highly non-uniform fields for high-voltage applications (opens in a new tab)

  6. Passive wireless sensors based on contactless air-filled substrate integrated waveguide technology

    … with a dynamic range of 3 Hz to 1 kHz near high-voltage apparatus. It also has a sensitivity of 1.86 (kHz)/(V/m), and can be interrogated from a distance of 80 cm. The feasible maximum bandwidth of the external electric field is up to 50 kHz overall. As a passive device, the sensor requires …

    manitoba Repository record for Passive wireless sensors based on contactless air-filled substrate integrated waveguide technology (opens in a new tab)

  7. Supervised and unsupervised deep learning models for partial discharge source detection and classification in electrical insulation

    Condition monitoring of electrical insulation of high voltage apparatus is of much importance for the reliable operation of electric power systems. An effective way to monitor the health of such systems is the measurement of partial discharges (PDs) in the insulation material. In order to prevent …

    manitoba Repository record for Supervised and unsupervised deep learning models for partial discharge source detection and classification in electrical insulation (opens in a new tab)

  8. An investigation into electrical degradation mechanisms within air-filled cavities in solid dielectric materials

    … in electrical insulation systems (EIS) in high voltage apparatus are not only caused by the thermal and mechanical stresses but also by the electrical stress during operational service. Imperfections in terms of cavities, craters, contaminants and electrical trees might seriously affect in …

    soton Repository record for An investigation into electrical degradation mechanisms within air-filled cavities in solid dielectric materials (opens in a new tab)

  9. Partial discharge source classification using pattern recognition algorithms

    … For single PD source identification, twelve high performance, applicable feature extraction techniques on PRPD patterns are employed to extract features. In order to present a comprehensive classification system, 10 well-known algorithms for the classification of PD sources have then been …

    manitoba Repository record for Partial discharge source classification using pattern recognition algorithms (opens in a new tab)

  10. The effect of nano size fillers on electrical performance of epoxy resin

    Epoxy resin is widely used in high voltage apparatus as insulation due to its excellent mechanical, electrical and chemical properties. Fillers are often added to epoxy resin to enhance its mechanical, thermal and chemical properties. With the new development in nanotechnology, it has been widely …

    soton Repository record for The effect of nano size fillers on electrical performance of epoxy resin (opens in a new tab)

  11. Impulse breakdown characteristics of SF6 and its mixtures in highly non-uniform field gaps

    … characteristics of SF? and its mixtures in highly non-uniform field gaps. Of particular interest were the effects of space charge, artificial irradiation, different gas mixtures, different additive gases and different wave fronts on the impulse breakdown characteristics. High divergent …

    strathclyde Repository record for Impulse breakdown characteristics of SF6 and its mixtures in highly non-uniform field gaps (opens in a new tab)