Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"High-Energy Trauma"”

  1. The Design, Analysis, Development, and Test of a High-Energy Trauma Prevention Safety Device

    … by 1999 [1]. These advancements have created a high-energy world, which poses a serious threat to the ever-growing population. Unprotected pedestrians come in all too frequent contact with these vehicles creating the potential for high-energy blunt force trauma. This thesis aims to prevent the …

    gvsu Repository record for The Design, Analysis, Development, and Test of a High-Energy Trauma Prevention Safety Device (opens in a new tab)

  2. Fracturas de alta energía en cuello y diáfisis femoral ipsilaterales: revisión sistemática de alcance 2019-2020

    … femoral shaft fracturas are due to unique and high energy trauma having vertical o basicervical fractures for the proximal femor, which makes diagnosis harder to catch and possibly delayed which can result in complications such as avascular necrosis of the femoral head. The first case with …

    rosario Repository record for Fracturas de alta energía en cuello y diáfisis femoral ipsilaterales: revisión sistemática de alcance 2019-2020 (opens in a new tab)

  3. Value of impact microindentation in the evaluation of bone fragility in clinical practice

    … It examines BMSi in individuals with low- and high-energy trauma fractures, changes in BMSi during osteoporosis treatment, and BMSi in patients with primary hyperparathyroidism and Cushing’s syndrome. In addition, the safety and acceptability of the procedure are evaluated. The findings provide …

    leiden Repository record for Value of impact microindentation in the evaluation of bone fragility in clinical practice (opens in a new tab)

  4. Clinical challenges and innovations in the treatment of pelvic fractures

    … patient populations: young patients following high-energy trauma and, with increasing frequency, frail elderly patients after low-energy injury. Optimal diagnostic and treatment algorithms for fragility fractures of the pelvis (FFP) remain lacking. This thesis demonstrates that routine CT …

    leiden Repository record for Clinical challenges and innovations in the treatment of pelvic fractures (opens in a new tab)

  5. Blauzdos kaulų įšnirimas. Diagnostikos problemos, komplikacijos. Klinikinis atvejis /

    … The most common reason of knee dislocation is a high-energy trauma, mainly caused by motor vehicle incidents, fall from significant height, but lately an increasing incidence of low-energy trauma caused dislocations is noted, especially among obese patients. This study presents literature review …

    vilnius Repository record for Blauzdos kaulų įšnirimas. Diagnostikos problemos, komplikacijos. Klinikinis atvejis / (opens in a new tab)

  6. Unstable Fractures of the Forearm: a project to improve clinical comprehension and to evaluate the results of the Interosseous Membrane Reconstruction

    … of 37 years; all the injuries had been caused by high energy trauma. Eight cases were chronic Essex-Lopresti injuries, two cases were acute. All these patients undervent an Interosseous Membrane Reconstruction (IOM), with different devices (frozen allograft, LARS, Ethibond braid and Ultratape). …

    bologna Repository record for Unstable Fractures of the Forearm: a project to improve clinical comprehension and to evaluate the results of the Interosseous Membrane Reconstruction (opens in a new tab)

  7. A cross sectional study of early functional outcomes of casting of tibial shaft fractures at the university teaching hospitals-adult hospital , Lusaka, Zambia.

    … fractures are a common presentation following high energy trauma such as road traffic accidents. The gold standard for the treatment of such injuries is by Intramedullary nailing, but in a resource-limited setting, the casting of such injuries is considered as appropriate. At the University …

    zambia Repository record for A cross sectional study of early functional outcomes of casting of tibial shaft fractures at the university teaching hospitals-adult hospital , Lusaka, Zambia. (opens in a new tab)

  8. Estudo da resistência mecânica de um compósito de matriz polimérica com adição de alumina

    … bone failures resulting from fractures caused by high energy trauma, as in the case of accidents involving automotive vehicles and/or human aging, in the face of osteoporosis, which is a disease characterized by the reduction of the mineral part of bones, making them more fragile, and …

    brazil-ufrn Repository record for Estudo da resistência mecânica de um compósito de matriz polimérica com adição de alumina (opens in a new tab)

  9. Viršutinių galūnių kompartmento sindromas vaikų amžiuje. Klinikinis atvejis /

    … from falls, motor vehicle collisions, or other high-energy trauma mechanisms. In children, the syndrome occurs more frequently in older boys due to increased physical activity and greater muscle mass. Diagnosis is typically based on clinical signs and symptoms, while laboratory and imaging …

    vilnius Repository record for Viršutinių galūnių kompartmento sindromas vaikų amžiuje. Klinikinis atvejis / (opens in a new tab)

  10. Impacto dos Acidentes de Motociclo na Traumatologia Pediátrica

    Introduction: Motorcycle accidents cause high energy trauma, being associated with elevated morbimortality. In Portugal, the minimal age to drive a motorcycle is sixteen years old. On the other hand, legislation prohibits transportation of passengers under the age of seven in motorcycles, unless …

    coimbro Repository record for Impacto dos Acidentes de Motociclo na Traumatologia Pediátrica (opens in a new tab)

  11. On hip fractures in adults under the age of 60

    … by preconceptions that fractures are due to high-energy trauma and the risk of osteoporosis is low. The patients’ perspectives have seldomly been presented and the surgical results were insufficiently described. This thesis project was developed in response to the relative lack of research on …

    lund Repository record for On hip fractures in adults under the age of 60 (opens in a new tab)

  12. On the treatment of tibial shaft fractures

    … fractures was 8.2 and in fractures exposed to high-energy trauma was 2.9. We conducted a prospective study of 53 unilateral, displaced and closed or type I open tibial shaft fractures, who were randomized by technique of minimization in two treatment groups, 27 patients in the nailed group and …

    goteborg Repository record for On the treatment of tibial shaft fractures (opens in a new tab)

  13. Three-dimensional kinematics and kinetics of the knee in posterior cruciate ligament reconstructed patients during daily activities

    … (PCL) typically occurs as a result of serious high-energy trauma. PCL reconstruction surgery is recognized as an important therapy method for such complex injuries. However, it remains unclear whether the PCL reconstructed (PCLR) patients can return to a normal gait pattern. The objective of …

    fu-berlin Repository record for Three-dimensional kinematics and kinetics of the knee in posterior cruciate ligament reconstructed patients during daily activities (opens in a new tab)

  14. Scaffolds for bone repair using computer aided design and manufacture

    … and serious problem. They occur as a result of high energy trauma, congenital conditions or are created surgically to treat bone tumours or infection. Currently the treatment for these conditions is awkward for the patient, takes a long time and has a high complication rate. An elegant solution …

    edinburgh Repository record for Scaffolds for bone repair using computer aided design and manufacture (opens in a new tab)

  15. Synthetic vascularized bone grafts

    … for segmental bone defects resulting from high-energy trauma, congenital deformity, infection or tumor resection. The current gold standard for repair of large long bone defects is the use of bone and blood vessels, as vascularized bone graft, harvested from another part of the body and …

    mcgill Repository record for Synthetic vascularized bone grafts (opens in a new tab)

  16. Etablierung einer multizentrischen Datenbank – Epidemiologie und klinisches Outcome von Tibiakopffrakturen

    … data collection on TPF across multiple regional trauma centers. The focus of the first study was twofold: first, to describe and analyze changes in fracture incidence in Germany for the first time, and second, to examine trends regarding fracture morphology, patients age, injury mechanism, and …

    lmu-germany Repository record for Etablierung einer multizentrischen Datenbank – Epidemiologie und klinisches Outcome von Tibiakopffrakturen (opens in a new tab)

  17. Improving the Mechanical and Functional Performance of Extrusion-based Additive Manufactured Scaffolds for Bone Tissue Engineering

    … of bone defects. Bone defects due to high energy trauma, congenital malfunction and severe non-union fractures require a bone substitute for regeneration. At present, the demand of most commonly used bone substitute autogenous cancellous bone grafts far exceeds the supply. Moreover, it …

    nus Repository record for Improving the Mechanical and Functional Performance of Extrusion-based Additive Manufactured Scaffolds for Bone Tissue Engineering (opens in a new tab)

  18. Effectiveness of surgical versus conservative treatment for distal femoral growth plate fractures: a systematic review

    … growth plate in children is typically due to a high-energy trauma such as contact sports or motor vehicle accidents. There is no clear evidence as to whether surgery or application of a plaster or splint is the best option for these injuries in terms of growth arrest and growth deformity. …

    adelaide Repository record for Effectiveness of surgical versus conservative treatment for distal femoral growth plate fractures: a systematic review (opens in a new tab)

  19. A Clinical Audit of the ReAktiv™ Posterior Dynamic Element (PDE) Orthosis on Ankle Trauma

    Background: Injuries sustained during High Energy Trauma (HET) often require complex surgery and extensive rehabilitation and can result in long-term issues such as pain, loss of function and limitations in physical activity. The ReAktiv Posterior Dynamic Element™ orthosis is a custom-made …

    auckland-tech Repository record for A Clinical Audit of the ReAktiv™ Posterior Dynamic Element (PDE) Orthosis on Ankle Trauma (opens in a new tab)